We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR K X5/2 LX4 TC is an industrial burner designed for high-capacity heating applications, delivering 154–850 kW output with a 250 mm nozzle and three-phase electrical supply. Ideal for process heating and combustion…

SKU 3G-FBR-00254

Also listed as: 00429941 · 004299 41 · 004299-41

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
nozzle mm
250
power kw max
850
power kw min
154
electrical supply
3

Datasheet Content

DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073568_C_en OR MODULATING WITH ELECTRONIC CONTROL BOX K X6/M-EL EVO - K X7/M-EL Dual fuel burners gas/light oil with electronic control box. Two stages progressive or modulating operation (if equipped with addition of optional modulation kit PID and probe: to guarantee an ideal proportionality of the power supplied to the thermal load). Composed by: die-cast aluminum body, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas or biogas. Gas train complete of: working valve class A, safety valve class A, gas valve proving pressure switch, minimum gaspressure switch, filter. Supplied with: nozzle, flange and gasket for installation on boiler, flexible hoses, line filter. The servomotors are indipendent and managed directly from the electronic control box of the burner: one servomotor for the gas modulator, one servomotor for the air shutter and one servomotor fo the light-oil modulator. The burners are equipped with a display that allows to: - adjust the operating parameters of the burner - visualize the flame intensity - adjust the operating curve of the burner (air / fuel ratio) With the addition of optional accessories (PID electronic regulator and probe) thanks to the most advanced systems for automatic modulation in mechanical or electronic version, the burner constantly ensures the proper thermal load. The maximum efficiency of the returns in each combustion point derived from the punctual adaptation of the thermal load to the heat requirements of the burner at any instant of operation. In the version with the electronic cam the fuel / combustion air curve, more extended, is fully exploited, guaranteeing excellent performance in terms of accuracy and speed, even during the calibration phase. A microprocessor monitors the different stages of the process and allows the correct repetition of the sequences of operation. Optional accessories: PID power modulator kit, probe, PC interface, VSD, O2 control, O2 + CO control, field bus (profibus, modbus, profinet), Touchscreen HMI panel. Fig. K X7/M-EL K X6/M-EL EVO - K X7/M-EL DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073568_C_en OR MODULATING WITH ELECTRONIC CONTROL BOX CONTROL BOX LAMTEC BT3 Fig. Control box Lamtec BT3 K X6/M-EL EVO - K X7/M-EL DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073568_C_en OR MODULATING WITH ELECTRONIC CONTROL BOX TECHNICAL DATA K X6/M-EL EVO - K X7/M-EL MODEL K X6/M-EL EVO K X7/M-EL Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 306/561-1118 367/765-1548 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 355/652-1300 427/890-1800 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 35.8/65.6-130.8 43/89.5-181 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 13.8/25.2-50.3 16.5/34.5-69.7 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R),I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stage progressive or modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Minimum pressure gas train D1"1/2 NATURAL GAS/L.P.G. ** [mbar] 46.2/21.5 81.8/38.4 Minimum pressure gas train D2" FS50 NATURAL GAS/L.P.G. ** [mbar] 39.8/19 69.6/33.6 Minimum pressure gas train DN65 FS65 NATURAL GAS/L.P.G. ** [mbar] 26.6/14 44.2/23.8 Minimum pressure gas train DN80 FS80 NATURAL GAS/L.P.G. ** [mbar] 21.9/12.1 35.4/20.3 Maximum pressure at the entry of valves (Pe. max) (D1"1/2 - D2") [mbar] 360 360 Maximum pressure at the entry of valves (Pe. max) (DN65 - DN80) [mbar] 500 500 LIGHT-OIL flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 30/55-110 36/75-152 Fuel: light-oil 1.5°E at 20°C = 6.2 cSt = 35sec Redwood N°1 Nominal electric power [kW] 3.5 5.25 Fan motor [kW] 2.2 4 Pump motor [W] 750 750 Nominal absorption powers [A] 6.8 9.5 Nominal absorption auxiliary [A] 0.55 0.55 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP40 IP40 Noisiness *** min. - max. [dB(A)] 82-83 84.3-86.6 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). K X6/M-EL EVO - K X7/M-EL DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073568_C_en OR MODULATING WITH ELECTRONIC CONTROL BOX OPERATING RANGE DIAGRAM 16 K X6/M-EL EVO 14 12 10 8 6 4 2 0 200 400 600 800 1000 1200 1400 Fig. X = Thermal power [kW] Y = Pressure in combustion chamber [mbar] The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. 16 K X7/M-EL 14 12 10 8 6 4 2 0 200 400 600 800 1000 1200 1400 1600 1800 2000 Fig. X = Thermal power [kW] Y = pressure in combustion chamber [mbar] The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. K X6/M-EL EVO - K X7/M-EL DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073568_C_en OR MODULATING WITH ELECTRONIC CONTROL BOX DIMENSIONS [MM] 40 183 A Rd A H D R1 G 20 B C TC - TL E R2 R4 R3 F1 - F2 Fig. Dimensions MODEL A B C D E F1 F2 G H TC* TL** R1 R2 R3 R4 RD Gas train weight K X6/M-EL EVO - D1"1/2 320 550 603 209 148 1040 1630 510 210 280 400 228 660 835 496 Rp 1"1/2 22 kg K X6/M-EL EVO - D2" 320 550 603 209 148 1040 1630 510 210 280 400 228 660 835 496 Rp 2" 22 kg K X6/M-EL EVO - DN65 320 550 603 209 148 1040 1630 510 210 280 400 228 660 835 541 DN65 27 kg K X6/M-EL EVO - DN80 320 550 603 209 148 1040 1630 510 210 280 400 228 700 890 578 DN80 37 kg K X7/M-EL - D1"1/2 320 550 603 209 148 1040 1630 510 210 280 400 228 660 835 496 Rp 1"1/2 22 kg K X7/M-EL - D2" 320 550 603 209 148 1040 1630 510 210 280 400 228 660 835 496 Rp 2" 22 kg K X7/M-EL - DN65 320 550 603 209 148 1040 1630 510 210 280 400 228 660 835 541 DN65 27 kg K X7/M-EL - DN80 320 550 603 209 148 1040 1630 510 210 280 400 228 700 890 578 DN80 37 kg * With spacers **…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR K X5/2 LX4 TC is an industrial burner designed for high-capacity heating applications, delivering 154–850 kW output with a 250 mm nozzle and three-phase electrical supply. Ideal for process heating and combustion systems requiring modulated power control.

Frequently Asked Questions

Where can I source the FBR K X5/2 LX4 TC burner worldwide?

3G Electric is an authorized distributor of FBR burners, including the K X5/2 LX4 TC model. We handle all logistics, customs clearance, and worldwide delivery. Contact us for availability and lead times on this 154–850 kW burner.

What is the lead time and shipping process for this FBR burner?

Lead times vary depending on current stock and destination. 3G Electric manages all shipping arrangements and customs documentation for global orders. Request a formal quote to confirm delivery schedule for the K X5/2 LX4 TC to your location.

What are the power and nozzle specifications of the FBR K X5/2 LX4 TC?

The FBR K X5/2 LX4 TC delivers modulated output from 154 kW to 850 kW maximum, with a 250 mm nozzle and three-phase electrical supply. It is designed for high-capacity process heating and industrial combustion systems requiring proportional power control.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
K X5/2 LX4 TL | Variant: variant_2
FBR
K X5/2 LX4 TL | Variant: variant_2
K X5/2 TC | Variant: variant_2 | Subgroup: Burner
FBR
K X5/2 TC | Variant: variant_2 | Subgroup: Burner
K X5/M/2 TC EL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/M/2 TC EL | Variant: variant_2 | Subgroup: Burner
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
K X7/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X7/2 TL | Variant: variant_2 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL