We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR variant_2 - Burners & Combustion
FBRBurners & Combustion

FBR variant_2

FBR K X7/M TL is a dual-fuel burner for gas and light-oil applications with two-stage modulating control. It delivers thermal power from 367 to 1548 mcal/h across a range of operating conditions. The unit features…

SKU 3G-FBR-00178

Also listed as: 00432031 · 004320 31 · 004320-31

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
11 kg
stage
2 stages sliding or modulating
fuel type
Dual fuel gas/light oil
nozzle mm
400
fan motor w
4
power kw max
1800
power kw min
427
ip protection
IP40
noisiness dba
84.3-86.6
pump motor kw
750
gas consumption
43/89.5-181
electrical supply
3
power supply info
- 50Hz
current absorption a
9.5
thermal power mcal h
367/765-1548
nominal electric power w
5.25
max combustion air temp c
60

Datasheet Content

DUAL FUEL GAS/LIGHT-OIL BURNERS TWO SK073567_B_en STAGES PROGRESSIVE OR MODULATING K X6/M EVO - K X7/M Dual fuel burners gas/light oil two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. Composed by die-cast aluminum body, air blower at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the easy setting and maintenance. GAS fuel available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas or biogas. Gas train composed by: working valve with regulation class A, safety valve class A, valve proving system, minimum gas pressure switch and filter stabilizer. Burners are supplied with nozzle, fuel selection switch, flange, gasket for installation on boiler, flexible hoses, line filter. Fig. K X6/M EVO - K X7/M K X6/M EVO - K X7/M DUAL FUEL GAS/LIGHT-OIL BURNERS TWO SK073567_B_en STAGES PROGRESSIVE OR MODULATING TECHNICAL DATA K X6/M EVO - K X7/M MODEL K X6/M EVO K X7/M Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 306/561-1118 367/765-1548 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 355/652-1300 427/890-1800 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 35.8/65.6-130.8 43/89.5-181 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 13.8/25.2-50.3 16.5/34.5-69.7 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R),I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stage progressive or modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 Minimum pressure gas train D1"1/2 NATURAL GAS/L.P.G. ** [mbar] 46.2/21.5 81.8/38.4 Minimum pressure gas train D2" FS50 NATURAL GAS/L.P.G. ** [mbar] 39.8/19 69.6/33.6 Minimum pressure gas train DN65 FS65 NATURAL GAS/L.P.G. ** [mbar] 26.6/14 44.2/23.8 Minimum pressure gas train DN80 FS80 NATURAL GAS/L.P.G. ** [mbar] 21.9/12.1 35.4/20.3 Maximum pressure at the entry of valves (Pe. max) (D1"1/2-D2") [mbar] 360 360 Maximum pressure at the entry of valves (Pe. max) (DN65-DN80) [mbar] 500 500 LIGHT-OIL flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 30/55-110 36/75-152 Fuel: light-oil 1.5°E at 20°C = 6.2 cSt = 35sec Redwood N°1 Nominal electric power [kW] 3.5 5.25 Fan motor [kW] 2.2 4 Pump motor [W] 750 750 Nominal absorption powers [A] 6.8 9.5 Nominal absorption auxiliary [A] 0.55 0.55 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP40 IP40 Noisiness *** min. - max. [dB(A)] 82-83 84.3-86.6 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). K X6/M EVO - K X7/M DUAL FUEL GAS/LIGHT-OIL BURNERS TWO SK073567_B_en STAGES PROGRESSIVE OR MODULATING OPERATING RANGE DIAGRAM 16 K X6/M EVO 14 12 10 8 6 4 2 0 200 400 600 800 1000 1200 1400 Fig. X = Thermal power [kW] Y = Pressure in combustion chamber [mbar] The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. 16 K X7/M 14 12 10 8 6 4 2 0 200 400 600 800 1000 1200 1400 1600 1800 2000 Fig. X = Thermal power [kW] Y = Pressure in combustion chamber [mbar] The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. K X6/M EVO - K X7/M DUAL FUEL GAS/LIGHT-OIL BURNERS TWO SK073567_B_en STAGES PROGRESSIVE OR MODULATING DIMENSIONS [MM] 40 183 H 320 D R1 320 TC-TL G RD E B C R4 R2 R3 F1 - F2 Fig. Dimensions MODEL B C D E F1 F2 G H TC* TL** R1 R2 R3 R4 RD Gas train weight K X6/M EVO - D1"1/2 398 402 209 148 1040 1624 510 213 280 400 228 510 684 496 Rp 1"1/2 22 kg K X6/M EVO - D2" 398 402 209 148 1040 1624 510 213 280 400 228 510 684 496 Rp 2" 22 kg K X6/M EVO - DN65 398 402 209 148 1040 1624 510 213 280 400 228 510 686 541 DN65 27 kg K X6/M EVO - DN80 398 402 209 148 1040 1624 510 213 280 400 228 550 740 578 DN80 37 kg K X7/M - D1"1/2 398 402 209 148 1040 1624 510 213 280 400 228 510 684 496 Rp 1"1/2 22 kg K X7/M - D2" 398 402 209 148 1040 1624 510 213 280 400 228 510 684 496 Rp 2" 22 kg K X7/M - DN65 398 402 209 148 1040 1624 510 213 280 400 228 510 686 541 DN65 27 kg K X7/M - DN80 398 402 209 148 1040 1624 510 213 280 400 228 550 740 578 DN80 37 kg * With spacer. ** For different flame tube lengths, please contact our Technical-Sales Department. BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L max M N min N* N max K X6/M EVO mm 340 368 M14 220 220 250 K X7/M mm 340 368 M14 220 220 250 K X6/M EVO - K X7/M DUAL FUEL GAS/LIGHT-OIL BURNERS TWO SK073567_B_en STAGES PROGRESSIVE OR MODULATING PRODUCT SPECIFICATION SHORT DESCRIPTION Dual fuel burners for gas and light-oil two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. DETAILED SPECIFICATION Dual fuel burners for gas and light-oil two stages progressive (hi-low flame) or modulating (PID…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR K X7/M TL is a dual-fuel burner for gas and light-oil applications with two-stage modulating control. It delivers thermal power from 367 to 1548 mcal/h across a range of operating conditions. The unit features IP40 protection and suits industrial heating systems requiring flexible fuel capability.

Frequently Asked Questions

Where can I buy the FBR K X7/M TL dual-fuel burner?

3G Electric is an authorized distributor of FBR burners worldwide. We source and deliver the K X7/M TL to industrial customers globally with full logistics and customs handling. Lead time and availability on request.

What is the thermal output range of the FBR K X7/M TL?

The FBR K X7/M TL delivers 367 kcal/h minimum to 1548 kcal/h maximum across operating conditions. Two-stage modulating control enables efficient part-load performance in industrial heating systems.

Can the FBR K X7/M TL switch between gas and light oil?

Yes. The K X7/M TL is a dual-fuel burner designed for both gas and light-oil applications with a 400 mm nozzle. Two-stage progressive or fully modulating control is available with optional modulation kit and probe.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
K X7/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X7/2 TL | Variant: variant_2 | Subgroup: Burner
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/2 TL | Variant: variant_2 | Subgroup: Burner
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
FBR
K X5/M/2 TL EL | Variant: variant_2 | Subgroup: Burner
K X6/2 EVO TL | Variant: variant_2 | Subgroup: Burner
FBR
K X6/2 EVO TL | Variant: variant_2 | Subgroup: Burner
K X6/M EVO TL | Variant: variant_2 | Subgroup: Burner
FBR
K X6/M EVO TL | Variant: variant_2 | Subgroup: Burner
K X5/2 TC | Variant: variant_2 | Subgroup: Burner
FBR
K X5/2 TC | Variant: variant_2 | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL