We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR G X5/2 TC SI - Burners & Combustion
FBRBurners & Combustion

FBR G X5/2 TC SI

FBR G X5/2 TC SI is a two-stage light-oil burner delivering 101–400 kW thermal output, ideal for industrial heating applications. Features a 215 mm nozzle, 33.7 kg/h maximum fuel flow, and 71–72 dBA noise level…

SKU 3G-FBR-00046

Brand
FBR
Item
G X5/2 TC SI
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
25 kg
stage
2 stages
fuel type
Light oil
nozzle mm
215
fan motor w
450
power kw max
400
power kw min
101
flow kg h max
33.7
flow kg h min
8.5
ip protection
IP 40
noisiness dba
71-72
electrical supply
1
power supply info
50Hz
current absorption a
2.7
thermal power mcal h
87/153-344
nominal electric power w
600
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS TWO STAGE SK070065_B_en G X4/2 - G X5/2 Light-oil burners two stage. They are composed by: two nozzles, aluminium frame, protection cover with noise reduction plate, combustion head with micro adjustment at high efficiency and high flame stability, hydraulic system of regulation combustive air on the two stages of flame. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Complete of connector 7 poles, flange and gasket for installation on boiler, nozzles, flexible pipes, line filter. Fig. 1 G X4/2 Fig. 2 G X5/2 G X4/2 - G X5/2 LIGHT-OIL BURNERS TWO STAGE SK070065_B_en TECHNICAL DATA G X4/2 - G X5/2 MODEL G X4/2 G X5/2 Flow 1°st. / min. 2°st. - max. 2°st. * [kg/h] 8/12-25 8.5/15-33.7 Thermal power 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 82/122-255 87/153-344 Thermal power 1°st. / min. 2°st. - max. 2°st. * [kW] 95/142-296 101/178-400 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [W] 300 600 Fan motor [W] 250 450 Nominal current absorption [A] 1.6 2.7 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. ** [db(A)] 68-69 71-72 Burner weight *** [kg] 15.5 25 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the combustion laboratory, with burner on operation on beta boiler to 1m of distance (UNI EN ISO 3746). *** For burner with cover in steel (F) please add 1 kg to the weight. OPERATING RANGE DIAGRAM G X4/2 - G X5/2 [mbar] 10 9 8 7 6 5 4 3 2 G X4/2 G X5/2 1 0 -1 80 120 160 200 240 280 320 360 400 [kW] Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. G X4/2 - G X5/2 LIGHT-OIL BURNERS TWO STAGE SK070065_B_en DIMENSIONS [MM] Fig. 4 Dimensions G X4/2 - G X5/2 MODEL A B C D E F G H I G X4/2 182 192 318 124 306 248 17 200 200 G X5/2 210 218 400 130 461 310 18 200 200 * See "flame tube length" BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 5 Boiler plate MODEL L min L* L max M N min N* N max G X4/2 mm 170 205 226 M10 130 140 160 G X5/2 mm 205 220 226 M10 140 150 180 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** G X4/2 mm 130 250 G X5/2 mm 215 335 ** For different flame lengths, please contact our Technical-Sales Department. G X4/2 - G X5/2 LIGHT-OIL BURNERS TWO STAGE SK070065_B_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners two stage. DETAILED SPECIFICATION Light-oil burner two stage composed by: • Aluminium frame; • Combustion head with micro adjustment at high efficiency and high flame stability; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Photoresistance for flame detection; • IP 40 electric protection level; • Hydraulic system of regulation combustive air on the two stages of flame. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. G X4/2 - G X5/2
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR G X5/2 TC SI is a two-stage light-oil burner delivering 101–400 kW thermal output, ideal for industrial heating applications. Features a 215 mm nozzle, 33.7 kg/h maximum fuel flow, and 71–72 dBA noise level. Suits medium to large commercial and industrial installations.

Frequently Asked Questions

Where can I source the FBR G X5/2 TC SI light oil burner?

3G Electric is an authorized supplier of FBR burners worldwide. We handle procurement, customs clearance, and logistics to your facility. Lead time and availability on request.

What is the fuel flow capacity of the FBR G X5/2 TC SI?

The FBR G X5/2 TC SI delivers a maximum fuel flow of 33.7 kg/h and minimum of 8.5 kg/h, supporting thermal output from 101 kW to 400 kW across two modulating stages.

What are the electrical specifications for this burner?

The FBR G X5/2 TC SI requires single-phase 50 Hz supply, with a fan motor rated 450 W and current absorption of 2.7 A. IP 40 protection and 71–72 dBA noise level suit industrial environments.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
G X5/2 TL SI
FBR
G X5/2 TL SI
X G X5.22 TC SI
FBR
X G X5.22 TC SI
X G X5 TC S
FBR
X G X5 TC S
X G X5.22 TL SI
FBR
X G X5.22 TL SI
G X4/2 TC SI
FBR
G X4/2 TC SI
X G X5S TC S
FBR
X G X5S TC S

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL