We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR G X4/2 TC SI - Burners & Combustion
FBRBurners & Combustion

FBR G X4/2 TC SI

FBR G X4/2 TC SI is a two-stage light-oil diesel burner delivering 117.4–630 kW thermal output with 9.9–53.1 kg/h fuel flow. The 250 W fan motor and IP 40 rating suit industrial heating and process applications…

SKU 3G-FBR-00050

Brand
FBR
Item
G X4/2 TC SI
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
15.5 kg
stage
2 stages
fuel type
Light oil
nozzle mm
130
fan motor w
250
power kw max
630
power kw min
117.4
flow kg h max
53.1
flow kg h min
9.9
ip protection
IP 40
noisiness dba
68-69
electrical supply
1
power supply info
1N~230V
current absorption a
1.6
thermal power mcal h
100.1/204-541.8
nominal electric power w
300
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS TWO STAGES SK070002_E_en STAGES ฀TWO BURNERS ฀ LIGHT-OIL ฀ FGP 50/2 EVO-3 Burners for light-oil two stages. They ฀฀are฀ composed by:฀fan฀at฀high฀pressurisation฀and฀reverse฀blades,฀combustion฀ head฀with฀adjustment฀at฀high฀ efficiency฀฀and฀ high฀flame฀stability฀and฀hydraulic฀system฀of฀regulation฀combustive฀air฀on฀the฀two฀stages฀of฀flame.฀ Compact฀฀ overall฀dimensions฀and฀disposition฀rationalized฀of฀the฀components฀with฀accessibility฀facilitated฀for฀the฀ operations฀฀of฀setting฀and฀maintenance. Complete฀of฀nozzles,฀flexible hoses and฀line฀filter. Complete฀ of฀flange฀and฀gasket฀for฀installation฀on฀generator. Fig. 1 FGP 50/2 EVO-3 FGP 50/2 EVO-3 LIGHT-OIL BURNERS TWO STAGES SK070002_E_en TECHNICAL฀DATA฀ FGP 50/2 EVO-3 MODEL FGP 50/2 EVO-3 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 9.9/20-53.1 Thermal power min. 1°st. / min. 2°st. - [Mcal/h] 100.1/204-541.8 max. 2°st. * Thermal power min. 1°st. / min. 2°st. - [kW] 117.4/237-630 max. 2°st. * Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 1.1 Fan motor [kW] 0.74 Nominal motor current absorption [A] 1.8 Nominal auxiliary absorption [A] 0.3 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness฀**฀min-max [dBA] 71-73 Burner฀weight฀*** [kg] 31 *฀Reference฀conditions:฀Environment฀฀temperature ฀20°C฀-฀Barometric฀pressure฀1013฀mbars฀-฀0 (zero) Height meters above mean sea level. **฀Sound power level detected at a distance of 1 meter in the combustion lab with burner working on boiler (UNI EN ISO 3746). ***฀For฀burner฀FGP 50/2 EVO-3 long฀head฀add฀1฀kg฀to฀the฀weight. OPERATING RANGE DIAGRAM FGP 50/2 EVO-3 [mbar] 12 10 8 6 4 2 0 0 100 200 300 400 500 600 700 [kW] Fig. 2 X฀=฀Thermal฀power฀Y฀=฀Pression฀in฀the฀combustion฀chamber The฀firing฀rates฀has฀been฀obtained฀based฀on฀test฀boilers฀in฀accordance฀with฀EN267฀standards฀and฀are฀indicative฀of฀matching฀the฀burner฀to฀the฀boiler.฀ For฀the฀correct฀operation฀of฀the฀burner,฀combustion฀chamber฀dimensions฀must฀be฀in฀accordance฀with฀current฀regulation.฀In฀case฀of฀non-compliance,฀ contact฀the฀manufacturer. FGP 50/2 EVO-3 LIGHT-OIL BURNERS TWO STAGES SK070002_E_en DIMENSIONS [MM] O F P C 20 E TC - TL A B D Fig. 3 Dimensions฀FGP 50/2 EVO-3 MODEL A B C D E F O P FGP 50/2 EVO-3 187 314 150 558 417 100 207 200 * see "flame tube length" FGP 50/2 EVO-3 LIGHT-OIL BURNERS TWO STAGES SK070002_E_en BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 4 Boiler฀plate MODEL L min L max M N min N* N max FGP 50/2 EVO-3 mm 205 226 M10 160 160 180 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** FGP 50/2 EVO-3 mm 250 335 ** For different flame lengths, please contact our Technical-Sales Department. FGP 50/2 EVO-3 LIGHT-OIL BURNERS TWO STAGES SK070002_E_en BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 2 1 Fig. 5 Burner฀signal฀description LEGEND 1) ON/OFF฀button 2) Reset฀from฀lockout฀button฀+฀status฀lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). FGP 50/2 EVO-3 LIGHT-OIL BURNERS TWO STAGES SK070002_E_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners two stages. DETAILED SPECIFICATION Light-oil burner two stages composed by: • Fan฀at฀high฀pressurisation฀and฀reverse฀blades; • Combustion฀head฀with฀adjustment฀at฀high฀performance฀and฀elevated฀flame฀stability; • Flange฀and฀insulating฀gasket฀for฀fixing฀at฀boiler; • Three-phase฀power฀supply; • Photoresistance฀for฀flame฀detection; • IP฀40฀electric฀protection฀level; • Easy฀extraction฀of฀combustion฀head฀without฀get฀off฀the฀burners฀by฀bolier. CONFORMING TO: • CE฀rules; • 2014/30/UE฀Directive฀E.M.C.; • 2014/35/UE฀Directive฀L.V.; • 2006/42/CE฀Directive฀M.D.; • 2014/68/UE฀(ART.4,PAR.3)฀Directive฀P.E.D.; • Reference฀rules:฀EN267฀(liquid฀fuel)฀-฀EN746-2฀(industrial฀thermoprocessing฀equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise฀protection. The฀illustrations฀and฀data฀here฀shown฀are฀indicative.฀F.B.R.฀Bruciatori฀S.r.l.฀reserves฀the฀right฀to฀bring,฀without฀any฀obligation฀of฀warning,฀any฀changes฀that฀would฀be฀appropriate฀to฀the฀continuing฀development฀of฀their฀products. FGP 50/2 EVO-3
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR G X4/2 TC SI is a two-stage light-oil diesel burner delivering 117.4–630 kW thermal output with 9.9–53.1 kg/h fuel flow. The 250 W fan motor and IP 40 rating suit industrial heating and process applications requiring modulating combustion control.

Frequently Asked Questions

Where can I buy the FBR G X4/2 TC SI diesel burner?

3G Electric is an authorised distributor of FBR burners worldwide. We source the G X4/2 TC SI and handle all logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

What is the lead time for the FBR G X4/2 TC SI?

Lead time on request. 3G Electric manages global procurement and logistics for industrial heating equipment. Contact our team with your project timeline and delivery location for an accurate quote.

What thermal output and fuel flow does the FBR G X4/2 TC SI deliver?

The G X4/2 TC SI delivers 117.4–630 kW thermal output with fuel flow of 9.9–53.1 kg/h across two modulating stages. The 250 W fan motor and IP 40 rating suit industrial process heating applications.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
X G X4/2 TL SI
FBR
X G X4/2 TL SI
X X4.22 TC SI
FBR
X X4.22 TC SI
X G X4 TC S
FBR
X G X4 TC S
G X5/2 TC SI
FBR
G X5/2 TC SI
G X4H TC c
FBR
G X4H TC c
X G X4S TC S
FBR
X G X4S TC S

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL