We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR X G OSR 2003 TXC R S - Burners & Combustion
FBRBurners & Combustion

FBR X G OSR 2003 TXC R S

FBR X G OSR 2003 TXC R S is a single-stage light-oil burner for cast iron boilers, delivering thermal power of 20.4–51 Mcal/h and rated current absorption of 1 A. Operating at 57–59 dBA with IP 40 protection, it…

SKU 3G-FBR-00100

Brand
FBR
Item
X G OSR 2003 TXC R S
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
11 kg
stage
Single stage for cast iron boilers
fuel type
Light oil
nozzle mm
77
fan motor w
100
preheater w
30-110
power kw max
36.7
power kw min
14.2
flow kg h max
3.1
flow kg h min
1.2
ip protection
IP 40
noisiness dba
57-59
electrical supply
1
power supply info
50Hz
current absorption a
1
thermal power mcal h
20.4-51
nominal electric power w
220
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 SK070039_A_en LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S Light-oil burners single stage. They are composed by: aluminium frame, protection cover with noise reduction plate, combustion head specific for cast iron boilers and combustion chambers with small length. Micro adjustment of the head, high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. In the versions H hydraulic device of closing air shutter. In the versions R preheater with control of temperature for soft and sicure ignitions also at low temperatures. On demand specific versions: kerosene, biodiesel. Complete of connector 7 poles, flange and gasket for installation on boiler, nozzle, flexible pipes, line filter. Fig. 1 G 0S Fig. 2 G 1S G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 SK070039_A_en TECHNICAL DATA G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S MODEL G 0HR G 0H G 1HR G 1H G 0SR G 0S G 1SR G 1S Flow min. - max. * [kg/h] 1.2-3.1 2.0-3.3 2.0-5.0 2.0-5.0 Thermal power min. - max. * [Mcal/h] 12.2-31.6 20.4-33.7 20.4-51 20.4-51 Thermal power min. - max. * [kW] 14.2-36.7 23.7-39.1 23.7-59.2 23.7-59.2 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) one stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [W] 190 120 220 130 Fan motor [W] 90 90 100 100 Nominal current absorption [A] 0.9 0.6 1 0.6 Pre-heater [W] 30-110 - 30-110 - Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. ** [dBA] 56-58 56-58 57-59 57-59 Burner weight [kg] 9 9 11 11 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the combustion laboratory, with burner on operation on beta boiler to 1m of distance (UNI EN ISO 3746). OPERATING RANGE DIAGRAM G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S Fig. 3 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 SK070039_A_en DIMENSIONS [MM] Fig. 4 Dimensions G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S MODEL A B C D E F G H I G0...2003 137 137 240 83 223 169 15 150 150 G1...2003 157 170 275 83 265 210 15 150 150 * See "flame tube length" BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 5 Boiler plate MODEL L min L* L max M N min N* N max G0...2003 mm 130 150 170 M8 90 110 130 G1...2003 mm 130 150 170 M8 90 110 130 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** G0...2003 mm 112 152 G1...2003 mm 112 152 ** For different flame lengths, please contact our Technical-Sales Department. G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S LIGHT-OIL BURNERS ONE STAGE SERIES G 2003 SK070039_A_en PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners one stage. DETAILED SPECIFICATION Light-oil burner one stage composed by: • Aluminium frame; • Combustion head specific for cast iron boilers and combustion chambers with small length; • Micro adjustment of the head, high efficiency and high flame stability; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Photoresistance for flame detection; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. G 0HR - G 0SR - G 0H - G 0S - G 1HR - G 1SR - G 1H - G 1S
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR X G OSR 2003 TXC R S is a single-stage light-oil burner for cast iron boilers, delivering thermal power of 20.4–51 Mcal/h and rated current absorption of 1 A. Operating at 57–59 dBA with IP 40 protection, it suits industrial heating applications requiring reliable oil combustion.

Frequently Asked Questions

Where can I buy the FBR X G OSR 2003 TXC R S light oil burner?

3G Electric supplies the FBR X G OSR 2003 TXC R S burner worldwide. We handle logistics, customs clearance, and delivery as an authorised distributor. Request a quote for lead time and pricing.

What is the thermal power output of the FBR X G OSR 2003 TXC R S?

The burner delivers 14.2–36.7 kW thermal power with a fuel flow of 1.2–3.1 kg/h. It operates at 57–59 dBA and draws 1 A electrical current. Rated for 50 Hz single-phase supply.

Is this burner suitable for cast iron boilers?

Yes. The FBR X G OSR 2003 TXC R S is designed for cast iron boilers as a single-stage light oil burner. It features IP 40 protection and weighs 11 kg, making it reliable for industrial heating applications.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
X G OSR 2003 TC R S
FBR
X G OSR 2003 TC R S
X G OSR LX TC R S
FBR
X G OSR LX TC R S
X G OSR LX TXC R S
FBR
X G OSR LX TXC R S
X G os 2003 TXC S
FBR
X G os 2003 TXC S
X G os LX TXC S
FBR
X G os LX TXC S
X G 1SR 2003 TC R S
FBR
X G 1SR 2003 TC R S

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL