We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR FGP 50/M TL EVO SA - Burners & Combustion
FBRBurners & Combustion

FBR FGP 50/M TL EVO SA

The FBR FGP 50/M TL EVO is a two-stage progressive light-oil burner for industrial heating applications, delivering 124–630 kW thermal output with modulating and hi-low flame control. IP44-rated with 78–82.5 dBA…

SKU 3G-FBR-00068

Brand
FBR
Item
FGP 50/M TL EVO SA
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
150 kg
stage
Progressive and modulating
fuel type
Light oil
nozzle mm
250
fan motor w
0.55
power kw max
630
power kw min
124
flow kg h max
53
flow kg h min
10.5
ip protection
IP44
noisiness dba
78-82.5
pump motor kw
0.37
electrical supply
3
power supply info
3~400V,1/N~230V-50Hz
current absorption a
1.2
thermal power mcal h
107/204-542
nominal electric power w
1.1
max combustion air temp c
60

Datasheet Content

LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING BRUCIATORIDIGASOLIOBISTADIO PROGRESSIVI OMODULANTI FGP฀50/M฀EVO Light-oil฀burners฀two฀stages฀progressive฀or฀modulating฀operation฀(if฀equipped฀with฀addition฀of฀optional฀ modulation฀kit฀PID฀and฀probe;฀to฀guarantee฀an฀ideal฀proportionality฀of฀the฀power฀supplied฀to฀the฀thermal฀ load). Composed฀฀by:฀fan฀at฀high฀pressurisation฀at฀reverse฀blades฀and฀combustion฀head฀with฀adjustment฀at฀high฀ efficiency฀and฀฀high฀flame฀stability. Compact฀฀overall฀dimensions฀and฀disposition฀rationalized฀of฀the฀components฀with฀accessibility฀facilitated฀for฀ the฀operations฀of฀setting฀and฀maintenance. Complete฀฀of฀nozzle,฀flexible฀pipes฀and฀line฀filter. Complete฀฀of฀flange฀and฀gasket฀for฀installation฀on฀generator. Fig. 1 FGP฀50/M฀EVO FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING TECHNICAL฀DATA฀FGP฀50/M฀EVO MODEL FGP฀50/M฀EVO Thermal฀power฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀* [Mcal/h] 107/204-542 Thermal฀power฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀* [kW] 124/237-630 LIGHT-OIL฀flow฀min.฀1°st.฀/฀min.฀2°st.฀-฀max.฀2°st.฀* [kg/h] 10.5/20-53 Fuel: LIGHT-OIL฀1.5°E฀at฀20°C฀=฀6.2฀cSt฀=฀35฀sec฀Redwood฀N°1 Intermitted฀working฀operation฀(min.฀1฀stop฀every฀24฀hours)฀two฀stages฀progressive฀or฀modulating Environmental฀conditions฀operation฀/฀storage: -15...+40°C฀/฀-20...+70°C,฀rel.฀humidity฀max.฀80% Max.฀temperature฀combustion฀air [°C] 60 Nominal฀electric฀power [kW] 1.1 Fan฀motor [kW] 0.55 Pump฀motor [kW] 0.37 Nominal฀fan฀motor฀current฀absorption [A] 1.4 Nominal฀pump฀motor฀current฀absorption [A] 1.2 Nominal฀auxiliary฀absorption [A] 0.6 Power฀supply: 3~400V,1/N~230V-50Hz Electric฀protection฀degree: IP44 * Reference฀conditions:฀Environment฀temperature฀20°C฀-฀Barometric฀pressure฀1013฀mbars฀-฀Altitude฀0฀metre฀(sea฀level). OPERATING฀RANGE฀DIAGRAM฀FGP฀50/M฀EVO <mbar> 13 11 9 7 5 3 )*30(92 1 -1 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 <kW> Fig. 2 X฀=฀Thermal฀power฀Y฀=฀Pression฀in฀the฀combustion฀chamber The฀firing฀rates฀has฀been฀obtained฀based฀on฀test฀boilers฀in฀accordance฀with฀EN267฀standards฀and฀are฀indicative฀of฀matching฀the฀burner฀to฀the฀ boiler.฀For฀the฀correct฀operation฀of฀the฀burner,฀combustion฀chamber฀dimensions฀must฀be฀in฀accordance฀with฀current฀regulation.฀In฀case฀of฀non- compliance,฀contact฀the฀manufacturer. FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING DIMENSIONS฀[MM] O A B F P D E TC - TL * C Fig. 3 Dimensions฀FGP฀50/M฀EVO MODEL A B C D E F O P FGP฀50/M฀EVO 329 274 746 150 416.5 100 207 200 C2:฀Overall฀dimension฀with฀the฀burner฀out฀in฀position฀of฀maintenance. * see฀"flame฀tube฀length" FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING BOILER฀PLATE * Suggested฀dimension฀of฀connection฀between฀burner and฀generator. Fig. 4 Boiler฀plate MODEL M N min N max L฀min L฀* L฀max FGP฀50/M฀EVO mm M10 205 226 160 160 180 FLAME฀TUBE฀LENGTH Flame฀tube฀length฀must฀be฀selected฀based฀on฀the฀specifications฀supplied฀by฀boiler฀manufacturer฀and,฀in฀any฀case,฀it must฀be฀greater฀than฀the฀thickness฀of฀the฀boiler฀door฀included฀its฀insulation. In฀case฀of฀boilers฀with฀flame฀inversion฀or฀front฀flue฀combustion฀chambers,฀it฀is฀necessary฀to฀insulate฀the฀area฀between the฀flame฀tube฀and฀front฀door฀with฀refractory฀material.฀This฀protection฀material฀must฀not฀impede฀flame฀tube฀ extraction. MODEL TC TL ** FGP฀50/M฀EVO mm 250 335 **฀For฀different฀flame฀lengths,฀please฀contact฀our฀Technical-Sales฀Department. FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING BURNER฀SIGNAL฀DESCRIPTION In฀the฀picture฀below฀there฀are฀indicated฀all฀the฀signalation฀present฀on฀the฀burner: 2 1 Fig. 5 Burner฀signal฀description฀ LEGEND 1) ON/OFF฀button 2) Reset฀from฀lockout฀button฀+฀status฀lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). FGP฀50/M฀EVO LIGHT-OIL฀BURNERS฀TWO฀STAGES฀PROGRESSIVE฀ SK070003_A_gb OR฀MODULATING PRODUCT฀SPECIFICATION SHORT฀DESCRIPTION Light-oil฀burners฀two฀stages฀progressive฀(hi-low฀flame)฀or฀modulating฀(PID฀fully฀modulating)฀if฀equipped฀with฀ addition฀of฀optional฀modulation฀kit฀and฀probe. DETAILED฀SPECIFICATION Light-oil฀burner฀two฀stages฀progressive฀(hi-low฀flame)฀or฀modulating฀(PID฀fully฀modulating)฀if฀equipped฀with฀addition฀ of฀optional฀modulation฀kit฀and฀probe;฀composed฀by: • Fan฀at฀high฀pressurisation฀at฀reverse฀blades; • Combustion฀head฀with฀adjustment฀at฀high฀performance฀and฀elevated฀flame฀stability; • Flange฀and฀insulating฀gasket฀for฀fixing฀at฀boiler; • Three-phase฀power฀supply; • Photodiode฀for฀flame฀detection; • IP฀44฀electric฀protection฀level; • Servomotor฀for฀air฀shutter฀and฀for฀the฀pressure฀regulator; • Easy฀extraction฀of฀combustion฀head฀without฀get฀off฀the฀burners฀by฀bolier; • Maximum฀light-oil฀pressure฀switch฀to฀stop฀the฀burner฀in฀case฀of฀the฀light-oil฀pressure฀on฀the฀return฀is฀higher฀then฀the฀set฀point value; • Safety฀air฀pressure฀switch฀to฀stop฀the฀burner฀in฀lock-out฀(by฀stopping฀the฀pump฀motor)฀in฀case฀of฀failed฀or฀anomalous฀fan operation; • Dedicated฀motor฀for฀the฀activation฀of฀the฀light-oil฀pump; • Set฀up฀for฀the฀additional฀specific฀kit฀that฀transforms฀burner฀operation฀as฀modulating฀i.e.฀the฀modulating฀kit฀allows฀to฀supply any฀power฀between฀the฀minimun฀and฀the฀maximum฀value฀based฀on฀instantaneous฀loading฀request. CONFORMING฀TO: • CE฀rules; • 2014/30/UE฀Directive฀E.M.C.; • 2014/35/UE฀Directive฀L.V.; • 2006/42/CE฀-฀2006/42/EG฀-฀2006/42/EC฀Directive฀M.D.; • Directive฀PED฀ 2014/68/UE฀ (ART.4,PAR.3); • Reference฀rules:฀EN267฀(liquid฀fuel)฀-฀EN746-2฀(industrial฀thermoprocessing฀equipment). STANDARD฀EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Power฀modulating฀kits฀for฀temperatures; • Power฀modulating฀kits฀for฀pressures; • Temperature฀probe฀0°C-400°C฀(PT฀100฀a฀0°฀C); • Temperature฀probe฀0°C-350°C฀(J฀probe); • Temperature฀probe฀0°C-1200°C฀(K฀probe); • Pressure฀probe฀0-3฀bar,฀0-6฀bar.฀0-16฀bar,฀0-20฀bar,฀0-30฀bar; • Noise฀protection. The฀illustrations฀and฀data฀here฀shown฀are฀indicative.฀F.B.R.฀Bruciatori฀S.r.l.฀reserves฀the฀right฀to฀bring,฀without฀any฀obligation฀of฀warning,฀any฀changes฀that฀would฀be฀appropriate฀to฀the฀continuing฀development฀of฀their฀products. FGP฀50/M฀EVO
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR FGP 50/M TL EVO is a two-stage progressive light-oil burner for industrial heating applications, delivering 124–630 kW thermal output with modulating and hi-low flame control. IP44-rated with 78–82.5 dBA noise levels, it integrates dual motors and operates on 3~400V, 1/N~230V-50Hz power for demanding combustion systems.

Frequently Asked Questions

Where can I buy the FBR FGP 50/M TL EVO SA diesel burner worldwide?

3G Electric is an authorized supplier of FBR diesel burners, including the FGP 50/M TL EVO SA. We handle logistics, customs, and delivery worldwide. Contact us for availability and lead-time details on this 124–630 kW unit.

What is the lead time and shipping process for the FBR FGP 50/M TL EVO SA?

Lead times vary based on origin and destination. 3G Electric manages all logistics and customs clearance for global orders. Contact our sales team with your location and required delivery date for a precise lead-time quote.

What are the power and fuel specifications of the FBR FGP 50/M TL EVO SA?

The FGP 50/M TL EVO SA delivers 124–630 kW thermal output on light oil, with progressive hi-low flame control or optional modulating (PID) control. It operates on 3~400V, 1/N~230V-50Hz, has IP44 protection, and produces 78–82.5 dBA at full load.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 50/M TC EVO SA
FBR
FGP 50/M TC EVO SA
FGP 100/M TL EVO SA
FBR
FGP 100/M TL EVO SA
FGP 130/M TL EVO SA
FBR
FGP 130/M TL EVO SA
FGP 130/M TC EVO SA
FBR
FGP 130/M TC EVO SA
FGP 100/M TC EVO SA
FBR
FGP 100/M TC EVO SA
FGP 50/2 TL EVO 3 SI
FBR
FGP 50/2 TL EVO 3 SI

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL