The FBR K 350/M TL EL EVO is a dual-fuel burner for gas and light-oil applications, delivering thermal power from 400 to 3500 mcal/h across two modulating stages. Rated at 3~400V electrical supply with 23.5 A current…

SKU 3G-FBR-00194

Brand
FBR
Item
variant_2
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
274 kg
stage
2 stages sliding or modulating
fuel type
Dual fuel gas/light oil
nozzle mm
560
fan motor w
9
power kw max
4070
power kw min
465
ip protection
IP40
noisiness dba
84-85
pump motor kw
2.2
gas consumption
47/140-409
electrical supply
3
power supply info
3~400V,
current absorption a
23.5
thermal power mcal h
400/1200-3500
nominal electric power w
12.5
max combustion air temp c
60

Datasheet Content

DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073571_A_gb OR MODULATING WITH ELECTRONIC CONTROL BOX K 350/M-EL EVO - K 450/M-EL EVO - K 550/M-EL EVO Dual fuel burners gas/light oil with electronic control box. Two stages progressive or modulating operation (if equipped with addition of optional modulation kit PID and probe; to guarantee an ideal proportionality of the power supplied to the thermal load). Composed by: fan at high pressurisation at reverse blades and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled and tested; composed by: working valve class A - safety valve class A - minimum gaspressure switch - gas valve proving pressure switch - filter Supplied with nozzle, fuel selection switch, flange and gasket for installation on boiler, flexible hoses, line filter. The servomotors are indipendent and managed directly from the electronic control box of the burner: one servomotor for the gas modulator, one servomotor for the air shutter and one servomotor fo the light-oil modulator. The burners are equipped with a display that allows to: - adjust the operating parameters of the burner - visualize the flame intensity - adjust the operating curve of the burner (air / fuel ratio) With the addition of optional accessories (probes) thanks to the most advanced systems for automatic modulation in mechanical or electronic version, the burner constantly ensures the proper gas / air ratio. The maximum efficiency of the returns in each combustion point derived from the punctual adaptation of the thermal load to the heat requirements of the burner at any instant of operation. In the version with the electronic cam the fuel / combustion air curve, more extended, is fully exploited, guaranteeing excellent performance in terms of accuracy and speed, even during the calibration phase. A microprocessor monitors the different stages of the process and allows the correct repetition of the sequences of operation. Optional accessories: PID power modulator kit, probe, PC interface, VSD, O2 control, O2 + CO control, field bus (profibus, modbus, profinet), Touchscreen HMI panel. K 350/M-EL EVO - K 450/M-EL EVO - K 550/M-EL EVO DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073571_A_gb OR MODULATING WITH ELECTRONIC CONTROL BOX CONTROL BOX LAMTEC BT3 Fig. Control box Lamtec BT3 K 350/M-EL EVO - K 450/M-EL EVO - K 550/M-EL EVO DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073571_A_gb OR MODULATING WITH ELECTRONIC CONTROL BOX TECHNICAL DATA MODEL K 350/M-EL EVO K 450/M-EL EVO K 550/M-EL EVO Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 400/1202-3508 438/1600-4500 426/2000-5500 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 465/1395-4070 510/1860-5232 496/2325-6395 Gas flow G20 (NAT. GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 49/132-408 52/187-526 50/234-643 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 20/53-163 20/72-203 20/90-248 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL, I2E(R)B/I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stage progressive or modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 60 Min. pressure gas train D2" FS50 NAT.GAS/L.P.G. ** [mbar] 200/79 324/128 -/226 Min. pressure gas train DN65 FS65 NAT. GAS/L.P.G. ** [mbar] 66/27 103/43 325/134 Min. pressure gas train DN80 FS80 NAT. GAS/L.P.G. ** [mbar] 53/23 82/35 223/90 Min. pressure gas train DN100 FS100 NAT. GAS/L.P.G. ** [mbar] 42/19 65/28 124/52 Max. pressure at the entry of valves (Pe. max) [mbar] 360-500 360-500 360-500 LIGHT-OIL flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 42/114-351 44/160-450 43/200-550 Fuel: light-oil 1.5°E at 20°C = 6.2 cSt = 35sec Redwood N°1 Nominal electric power [kW] 12 14 18 Fan motor [kW] 9.2 11 15 Pump motor [kW] 2.2 2.2 2.2 Nominal fan motor current absorption [A] 18.8 22 30 Nominal pump motor current absorption [A] 4.7 4.7 4.7 Nominal absorption auxiliary [A] 0.5 0.5 0.5 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP40 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). K 350/M-EL EVO - K 450/M-EL EVO - K 550/M-EL EVO DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073571_A_gb OR MODULATING WITH ELECTRONIC CONTROL BOX OPERATING RANGE DIAGRAM [ mbar] 25 K 350/M-EL EVO 20 15 10 5 0 0 500 1000 1500 2000 2500 3000 3500 4000 4500 [kW] Fig. X = Thermal power Y = pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. [ mbar] 25 K 450/M-EL EVO 20 15 10 5 0 200 1200 2200 3200 4200 5200 6200 [kW] Fig. X = Thermal power Y = pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. K 350/M-EL EVO - K 450/M-EL EVO - K 550/M-EL EVO DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073571_A_gb OR MODULATING WITH ELECTRONIC CONTROL BOX 25 [ mbar] K 550/M-EL EVO 20 15 10 5 0 0 1000 2000 3000 4000 5000 6000 7000 [kW] Fig. X = Thermal power Y = pressure in combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. K 350/M-EL EVO - K 450/M-EL EVO - K 550/M-EL EVO DUAL FUEL GAS/LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE SK073571_A_gb OR MODULATING WITH ELECTRONIC CONTROL BOX DIMENSIONS [MM] Fig. Dimensions MODEL A B C D E F G H R1 R2 R3 R4 K 350/M-EL EVO - D2" 490 600 550 380 160 1170 650 275 320 720 855 890 K 350/M-EL EVO - DN65 490 600 550 380 160 1170 650 275 320 745 890 780 K 350/M-EL EVO - DN80 490 600 550 380 160 1170 650 275 320 745 915 800 K 350/M-EL EVO - DN100 490 600 550 380 160 1170 650 275 320 795 975 840 K 450/M-EL EVO - D2" 490 600 550 380 160 1170 650 275 320 720 855 890 K 450/M-EL EVO - DN65 490 600 550 380 160 1170 650 275 320 745 890 780 K 450/M-EL EVO - DN80 490 600 550 380 160 1170 650 275 320 745 915 800 K 450/M-EL EVO - DN100 490 600 550 380 160 1170 650 275 320 795 975 840 K 550/M-EL EVO - D2" 490 600 550 380 160 1170 650 275 320 720 855 890 K 550/M-EL EVO - DN65 490 600 550 380 160 1170 650 275 320 745…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR K 350/M TL EL EVO is a dual-fuel burner for gas and light-oil applications, delivering thermal power from 400 to 3500 mcal/h across two modulating stages. Rated at 3~400V electrical supply with 23.5 A current absorption, it suits industrial heating systems requiring flexible fuel switching.

Frequently Asked Questions

Where can I buy the FBR K 350/M TL EL EVO burner worldwide?

Order the FBR K 350/M TL EL EVO from 3G Electric, an authorized distributor. We source and ship to facilities globally, handling customs and logistics. Lead time on request.

What is the lead time for the FBR K 350/M TL EL EVO?

Lead time depends on stock availability and destination. Contact 3G Electric for a quote — we manage customs clearance and arrange worldwide delivery to your facility.

Can the FBR K 350/M TL EL EVO run on both gas and light oil?

Yes. The FBR K 350/M TL EL EVO is a dual-fuel burner rated for gas and light oil. It delivers 400–3500 mcal/h across 2 modulating stages, with 3~400V, 23.5 A electrical supply, and suits flexible industrial heating systems.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
K 4/M/2 TL EL EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/M/2 TL EL EVO 2 | Variant: variant_2 | Subgroup: Burner
K 190/M TL EL (1) | Variant: variant_2 | Subgroup: Burner with electronic cam
FBR
K 190/M TL EL (1) | Variant: variant_2 | Subgroup: Burner with electronic cam
K 350/M TL EL EVO (1) | Variant: metano | Subgroup: Burner with electronic cam
FBR
K 350/M TL EL EVO (1) | Variant: metano | Subgroup: Burner with electronic cam
K 4/M/2 TC EL EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/M/2 TC EL EVO 2 | Variant: variant_2 | Subgroup: Burner
K 4/2 TL EVO 2 | Variant: variant_2 | Subgroup: Burner
FBR
K 4/2 TL EVO 2 | Variant: variant_2 | Subgroup: Burner
GAS P 350/M CE TL EL EVO (1) | Variant: variant_2 | Subgroup: Burner with electronic cam
FBR
GAS P 350/M CE TL EL EVO (1) | Variant: variant_2 | Subgroup: Burner with electronic cam

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL