The FBR FGP 160/2 TL SI is a two-stage light-oil diesel burner for industrial heating applications, delivering 534–1900 kW thermal power with a maximum fuel flow of 160 kg/h. It features low-NOx technology and IP 40…

SKU 3G-FBR-00074

Brand
FBR
Item
FGP 160/2 TL SI
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
47 kg
stage
Serie low nox
fuel type
Light oil
nozzle mm
180
fan motor w
1.5
power kw max
1900
power kw min
534
flow kg h max
160
flow kg h min
45
ip protection
IP 40
noisiness dba
78-82.5
pump motor kw
0.37
electrical supply
3
power supply info
3~400V, 1N~230V
current absorption a
0.3
thermal power mcal h
374/765-1634
nominal electric power w
1.6
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS TWO STAGES FGP 130/2 EVO - FGP 160/2 Light-oil burners two stages. Composed by: fan at high pressurisation, combustion head with adjustment at high efficiency and high flame stability and hydraulic system of regulation combustive air on the two stages of flame. The burners are equipped with two motors : air blower motor + pump motor. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Complete of 2 nozzles, 2 flexible hoses and line filter. Complete of flange and gasket for installation on generator. FGP 130/2 EVO - FGP 160/2 LIGHT-OIL BURNERS TWO STAGES TECHNICAL DATA FGP 130/2 EVO MODEL FGP 130/2 EVO Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 28.3/60-130 Thermal power min. 1°st. / min. 2°st. - [Mcal/h] 289/612-1326 max. 2°st. * Thermal power min. 1°st. / min. 2°st. - [kW] 336/712-1542 max. 2°st. * Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 3 Fan motor [kW] 2.2 Pump motor [kW] 0.37 Nominal fan motor current absorption [A] 4.35 Nominal pump motor current absorption [A] 1.2 Nominal auxiliary absorption [A] 0.82 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness ** min-max [dBA] 83.8-84 Weight *** [kg] 84 * Reference conditions : Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746). *** For burner with long head add 2 kg. OPERATING RANGE DIAGRAM FGP 130/2 EVO [mbar] 18 16 14 12 10 8 6 4 2 0 200 400 600 800 1000 1200 1400 1600 [kW] Fig. X = Therma l power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. FGP 130/2 EVO - FGP 160/2 LIGHT-OIL BURNERS TWO STAGES TECHNICAL DATA FGP 160/2 MODEL FGP 160/2 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 36.7/75-160 Thermal power min. 1°st. / min. 2°st. - [Mcal/h] 374/765-1634 max. 2°st. * Thermal power min. 1°st. / min. 2°st. - [kW] 435/889-1900 max. 2°st. * Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 5 Fan motor [kW] 4 Pump motor [kW] 0.37 Nominal fan motor current absorption [A] 7.45 Nominal pump motor current absorption [A] 1.2 Nominal auxiliary absorption [A] 0.82 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness ** min-max [dBA] 84.4-85.4 Weight *** [kg] 95 * Reference conditions :Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746). *** For burner with long head add 2 kg. OPERATING RANGE DIAGRAM FGP 160/2 [mbar] 18 16 14 12 10 8 6 4 2 0 200 400 600 800 1000 1200 1400 1600 1800 2000 [kW] Fig. X = Therma l power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. FGP 130/2 EVO - FGP 160/2 LIGHT-OIL BURNERS TWO STAGES DIMENSIONS [MM] G F H C I E A B TC - TL * D1-D2 J K Fig. Dimensions FGP 130/2 EVO - FGP 160/2 MODEL A B C D1 D2 E F G H I J K FGP 130/2 EVO 383 343 209 803 1383 510 211 320 320 20 183 40 FGP 160/2 383 405 209 803 1383 510 211 320 320 20 183 40 * see "flame tube length" D2: Overall dimension with the burner out in position of maintenance. FGP 130/2 EVO - FGP 160/2 LIGHT-OIL BURNERS TWO STAGES BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L max M N min N* N max FGP 130/2 EVO mm 340 368 M14 230 230 250 FGP 160/2 mm 340 368 M14 230 230 250 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** FGP 130/2 EVO mm 210 400 FGP 160/2 mm 210 400 ** For different flame lengths, please contact our Technical-Sales Department. FGP 130/2 EVO - FGP 160/2 LIGHT-OIL BURNERS TWO STAGES BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 1 2 Fig. Burner signal description LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). FGP 130/2 EVO - FGP 160/2 LIGHT-OIL BURNERS TWO STAGES PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners two stages. DETAILED SPECIFICATION Light-oil burner two stages composed by: • Fan at high pressurisation at reverse blades FGP130/2 EVO; • Fan at high pressurisation FGP160/2; • Combustion head with adjustment at high performance and elevated flame stability; • Flange and…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR FGP 160/2 TL SI is a two-stage light-oil diesel burner for industrial heating applications, delivering 534–1900 kW thermal power with a maximum fuel flow of 160 kg/h. It features low-NOx technology and IP 40 protection, suitable for medium to large-scale combustion systems.

Frequently Asked Questions

Where can I source the FBR FGP 160/2 TL SI diesel burner worldwide?

3G Electric is an authorized FBR distributor offering the FGP 160/2 TL SI globally. We handle sourcing, customs clearance, and logistics for delivery to your facility. Lead time on request.

What is the thermal output range and fuel consumption of the FGP 160/2 TL SI?

The FBR FGP 160/2 TL SI delivers 534–1900 kW thermal power with a maximum fuel flow of 160 kg/h and minimum flow of 45 kg/h. Two-stage modulation optimizes efficiency across load ranges.

What electrical specifications and protection rating does this burner have?

Supply: 3-phase 400V + 1-phase 230V. IP 40 protection standard. Current absorption 0.3 A. Fan motor 1.5 kW, pump motor 0.37 kW. Suitable for indoor and industrial heating installations.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 160/2 LX TL SI
FBR
FGP 160/2 LX TL SI
FGP 160/2 TC SI
FBR
FGP 160/2 TC SI
FGP 160/2 LX TC SI
FBR
FGP 160/2 LX TC SI
FGP 160/M TL SA
FBR
FGP 160/M TL SA
FGP 75/2 TL SI
FBR
FGP 75/2 TL SI
FGP 160/M TC SA
FBR
FGP 160/M TC SA

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL