We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Image not available
HoneywellBurner Controls

Honeywell Relay CM 32 PR TW30/TS5

Honeywell Relay CM 32 PR TW30/TS5 is a burner control for atmospheric pre-mixed gas burners with intermittent operation and manual/electric reset capability. Non-volatile lockout ensures safety during shutdown…

SKU 3G-CBM-06045

Also listed as: REL 45167 · REL-45167

Brand
Honeywell
Item
Relay CM 32 PR TW30/TS5
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Honeywell
type
CM32PR
operation
intermittent
reset type
manual and electric reset
application
atmospheric pre-mixed gas burners
lockout type
non-volatile

Datasheet Content

MICROFLA T SERIES APPLICATION TYPES CM32PR CE32PR This range of electronic gas burner control systems has been specifically designed for atmospheric pre-mixed gas burners for intermittent operation (systems for non­ AUTOMATIC CONTROL SYSTEMS WITH permanent operation). MANUAL AND ELECTRIC RESET FOR The control unit type CM32PR is provided with non-volatile PRE-MIXED GAS BURNERS AND lockout, i.e. the restart from the safety shutdown condition can only be accomplished by a manual reset of the system. INSTALLATIONS (PROVIDED WITH FREE The control unit type CE32PR is provided with volatile TERMINALS FOR AN EXTERNAL lockout, i.e. a restart from the lockout condition can be IGNITION DEVICE) accomplished by an interruption of the mains power supply and its subsequent restoration or by means of the heat demand to the control. The automatic burner control units of this series are suitable for: - combi boilers (only type CM32PR); - heating boilers (only type CM32PR); - water heaters. These controls are provided with free terminais for an external ignition device (selected the appliance manufacturer). As a result, these controls can be used for applications where ignition is particularly difficult, thus avoiding the use of pilot valves and hot surface ignitors. To reduce the electromagnetic interference produced by ignition devices, these control units can be fitted with our electronic ignition transformers type TC1AF-TC2AF with inbuilt E.M.C. filter (see technical sheets about "Electronic ignition transformers"). FEATURES TABLE 1 shows the main features of this series. Other important features are: - EC certification type (CE Reg. N ° 63AT1990) in accordance with the European Gas Directive Appliance 90/396/EEC amended by 93/68/EEC; in compliance with EN 298 (European standard for automatic gas burner control systems and flame detectors for gas burners); output for the control of the ignition device by means of supply voltage; possibility of mounting a resistor (0 + 220 ohm) in series to the valve outputs, in case the valves operate with direct current obtained through the rectification of the supply alternate current by means of one or more diodes; - for non-volatile lockout versions, possibility of mounting a resistor (0 + 470 Kohm) in series to the lockout signal output, to avoid possible damages to the control in case the connections of the reset push-button and the connections of the lockout signal are reversed; - two independent safety contacts in series on the gas valve output; - flame monitoring by the rectification property of the flame (ionization). · . r _ . ·--:- .· -- . .- - 7�- - .. • _ � ��6'"' .. . .-:. . ·� ."· . . -. .. - :.\c�-- . -. - .·

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Honeywell Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Honeywell Relay CM 32 PR TW30/TS5 is a burner control for atmospheric pre-mixed gas burners with intermittent operation and manual/electric reset capability. Non-volatile lockout ensures safety during shutdown, serving industrial heating and combustion applications.

Frequently Asked Questions

Where can I buy the Honeywell CM 32 PR TW30/TS5 in your region?

3G Electric supplies the Honeywell Relay CM 32 PR TW30/TS5 with delivery to your location. We handle all customs clearance and logistics to your facility. Contact us for availability and pricing in USD.

What is the lead time for the Honeywell CM 32 PR control?

Lead time varies depending on warehouse location and customs processing. Contact 3G Electric for a specific delivery timeline. We manage customs documentation and arrange shipment to your site.

What applications does the Honeywell CM 32 PR suit?

The CM 32 PR is designed for atmospheric pre-mixed gas burners with intermittent operation. It features manual and electric reset capability with non-volatile lockout for safety during shutdown in industrial heating and combustion systems.

Used in

Common applications for Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

Honeywell Products

3G Electric supplies Honeywell burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Satronic
Satronic
Relay CM 32 TW30/TS5
Satronic
Satronic
Relay CM 32 PR TW30/TS10
Satronic
Satronic
Relay CM 32 TW20/TS10
Relay CM 32 TW30/TS5
Brahma
Relay CM 32 TW30/TS5
Relay CM 32 TW30/TS10
Brahma
Relay CM 32 TW30/TS10
Satronic
Satronic
Relay DTM 31 PR TW30/TS10

More from Honeywell

View all Honeywell parts
Honeywell
Honeywell
Relay CM 31 TW40/TS10
Relay MMI 810.13
Honeywell
Relay MMI 810.13
Honeywell
Honeywell
MMG 810.1 MOD 45 relay
Honeywell
Honeywell
MMI 811.35 relay
Honeywell
Honeywell
MMI 810.35 relay
Honeywell
Honeywell
Relay MMI 810.33
Honeywell
Honeywell
Relay MMI 810.40.34
Honeywell
Honeywell
Relay MMI 810.1 MOD 43