We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR FGP 100/M TC EVO SA - Burners & Combustion
FBRBurners & Combustion

FBR FGP 100/M TC EVO SA

FBR FGP 100/M TC EVO is a light-oil burner for industrial heating applications, featuring progressive and modulating stages with maximum thermal output of 1020 kcal/h and flow rate up to 100 kg/h. IP40 rated for…

SKU 3G-FBR-00078

Brand
FBR
Item
FGP 100/M TC EVO SA
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
150 kg
stage
Progressive and modulating
fuel type
Light oil
nozzle mm
235
fan motor w
1.5
power kw max
1186
power kw min
190
flow kg h max
100
flow kg h min
16.1
ip protection
IP40
noisiness dba
82-83.6
pump motor kw
0.75
electrical supply
3
power supply info
3~400V,1/N~230V-50Hz
current absorption a
1.6
thermal power mcal h
164.2/408-1020
nominal electric power w
2.4
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M Burners for light-oil two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. Composed by: air blower at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the easy setting and maintenance. Complete of nozzle, flexible pipes and line filter. Complete of flange and gasket for installation on generator. Fig. FGP 130/M EVO FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING TECHNICAL DATA FGP 75/M - FGP 100/M EVO MODEL FGP 75/M FGP 100/M EVO Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [Mcal/h] 178/357-816 164.2/408-1020 Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [kW] 207/415-949 190/474-1186 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 17.5/35-80 16.1/40-100 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C฀/฀-20...+70°C,฀rel. humidity max.฀80% Max. temperature combustion air [°C] 60 60 Nominal electric power [kW] 2.2 2.4 Fan motor [kW] 1.5 1.5 Pump motor [kW] 0.55 0.75 Nominal fan motor current absorption [A] 3.4 4.5 Nominal pump motor current absorption [A] 1.6 1.6 Nominal auxiliary absorption [A] 0.82 0.82 Power supply: 3~400V,1/N~230V-50Hz Electric protection degree: IP40 IP40 Noiseness min. - max. ** [dBA] 78-82.5 82-83.6 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING OPERATING RANGE DIAGRAM FGP 75/M [mbar] FGP 75/M [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. OPERATING RANGE DIAGRAM FGP 100/M EVO [mbar] [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING TECHNICAL DATA FGP 130/M EVO MODEL FGP 130/M EVO Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [Mcal/h] 289/612-1326 Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [kW] 336/712-1542 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 28.3/60-130 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C฀/฀-20...+70°C,฀rel. humidity max.฀80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 3 Fan motor [kW] 2.2 Pump motor [kW] 0.75 Nominal fan motor current absorption [A] 4.35 Nominal pump motor current absorption [A] 1.6 Nominal auxiliary absorption [A] 0.82 Power supply: 3~400V,1/N~230V-50Hz Electric protection degree: IP40 Noiseness min. - max. ** [dBA] 78-82.5 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). OPERATING RANGE DIAGRAM FGP 130/M EVO [mbar] 17 15 13 11 9 7 5 3 1 -1 0 200 400 600 800 1000 1200 1400 1600 1800 2000 [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FGP 75/M - FGP 100/M EVO - FGP 130/M EVO - FGP 160/M LIGHT-OIL BURNERS SK070090_C_en TWO STAGES PROGRESSIVE OR MODULATING TECHNICAL DATA FGP 160/M MODEL FGP 160/M Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [Mcal/h] 374/765-1634 Thermal power min. 1°st. /min. 2°st. - max. 2°st. * [kW] 435/889-1900 Flow min. 1°st. / min. 2°st. - max. 2°st. * [kg/h] 36.7/75-160 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C฀/฀-20...+70°C,฀rel. humidity max.฀80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 5 Fan motor [kW] 4 Pump motor [kW] 0.75 Nominal fan motor current absorption [A] 7.45 Nominal pump motor current absorption [A] 2 Nominal auxiliary absorption [A] 0.82 Power supply: 3~400V,1/N~230V-50Hz Electric protection degree: IP40 Noiseness min. - max. ** [dBA] 84.4-85.4 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). OPERATING RANGE DIAGRAM FGP 160/M [mbar] 17 15 13…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR FGP 100/M TC EVO is a light-oil burner for industrial heating applications, featuring progressive and modulating stages with maximum thermal output of 1020 kcal/h and flow rate up to 100 kg/h. IP40 rated for standard industrial combustion environments.

Frequently Asked Questions

Where can I source the FBR FGP 100/M TC EVO SA burner worldwide?

Order from 3G Electric, an authorized FBR distributor. We handle worldwide delivery, logistics coordination, and customs clearance. Lead time and availability on request.

What is the maximum thermal output of the FGP 100/M TC EVO SA?

Maximum thermal output is 1020 kcal/h with a flow rate up to 100 kg/h. Minimum output is 190 kW with 16.1 kg/h flow rate in low-stage operation.

Can the FBR FGP 100/M TC EVO SA be configured for full modulation?

Yes. The burner is supplied with progressive two-stage (hi-low flame) capability standard. Optional modulation kit and probe enable PID fully modulating operation for precise combustion control.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 130/M TC EVO SA
FBR
FGP 130/M TC EVO SA
FGP 100/M TL EVO SA
FBR
FGP 100/M TL EVO SA
FGP 50/M TC EVO SA
FBR
FGP 50/M TC EVO SA
FGP 130/M TL EVO SA
FBR
FGP 130/M TL EVO SA
FGP 50/M TL EVO SA
FBR
FGP 50/M TL EVO SA
FGP 100/2 TC EVO SI
FBR
FGP 100/2 TC EVO SI

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL