We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Pactrol Microgas P25F FTL/V24 427001/V24 - Controls
PactrolControls

Pactrol Microgas P25F FTL/V24 427001/V24

Pactrol Microgas P25F FTL/V24 427001/V24

SKU 3G-CBM-04702

Also listed as: PAC 44030 · PAC-44030

Brand
Pactrol
Item
Microgas P25F FTL/V24 427001/V24
Category
Controls
UNSPSC
39121026 — Control power transformer
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Pactrol
ce certified
Yes
spark energy
> 4 mJ (W.H.I.T.B.)
internal fuse
2 A HPC (20 mm)
pre purge time
1.5–50 seconds
supply voltage
230 V + 10% - 15%
aps type options
2 or 3 terminal or not present
humidity maximum
90% RH
supply frequency
50–60 Hz (± 3 Hz)
power consumption
15 VA
pre ignition time
1.0–50 seconds
spark gap tolerance
2.5–4.5 mm
lockout type options
volatile or non-volatile
open circuit voltage
15 kV minimum (30 pf loading)
relay contact rating
1 A Inductive 0.6 pf @ 230 V ac
appliance type options
fanned or atmospheric
certification standard
EN 298:2003
flame on response time
1 second max
ambient temperature range
-10°C to 70°C
flame detection principle
Rectification
supply phase relationship
Sensitive to Live and Neutral phase reversal
total maximum load current
2 A
external transformer rating
230 V:230 V 2 VA
number of ignition attempts
1–5
minimum flame current required
1 µA @ 230 V ac supply
flame detector electrode configuration
Dual or single probe ignition & detection

Datasheet Content

MicroGasTM P25 Series A Family of Full Sequence Controls Certified to EN 298 : 2003 technology factfile Microcontroller technology lies at the heart of this microgas™ range of full sequence controls, offering a large number of control and timing options not normally available from simpler units. This compact family of control units offer safe start-up and supervision of a wide range of gas burning appliances, for domestic, commercial and industrial applications. An equally wide range of control sequences and timing options are available, all based on an integral spark ignition system. By a combination of hardware and software selection, customers can be offered forced or atmospheric sequences, volatile or non-volatile lockout, a range of spark rates and many timing and logic functions, including multiple ignition attempts and post purge. This 4270 series is CE Certified and fully complies with the requirements of the GAD via EN 298 : 2003. Typical applications • Combination Boilers • Condensing Boilers • Heating Boilers • Water Heaters • Warm Air Heaters • Radiant Tube Heaters key features • Programmable logic and timings • Atmospheric or fanned application • Integral spark and flame detection • Multiple ignition attempts • Volatile or non-volatile lockout • Dual or single probe for ignition and flame detection • Post purge • Compact size • Optional ‘floating supply’ capability for flame detector • Dual, self-checking safety system • CE Certification to EN 298 : 2003 system operation sequence To keep abreast of current developments, controls may be subject to change without notice. Such changes may affect the accuracy of information contained in this data-sheet, and the manufacturers advice should be sought if any problems arise. Pactrol Controls Limited Unit 3, Three Sisters Enterprise Park, Antler Court, Ashton-in-Makerfield, Wigan WN4 8DU, UK Technical specification Electrical Supply Voltage 230 V + 10% - 15% Frequency 50 - 60Hz (+/- 3Hz) Power Consumption 15VA Supply Phase Relationship Sensitive to Live and Neutral phase reversal Internal fuse 2A HPC (20mm) Contact Ratings All relay drives where used 1A Inductive 0.6pf @230V ac Total maximum load current: 2A Ignition Open circuit voltage 15kV Minimum (30pf loading) Spark energy > 4mJ (W.H.I.T.B.) Spark gap tolerance 2.5mm to 4.5mm Spark rate as specified in description of function Flame Detection Principle Rectification Electrode configuration Dual or single probe ignition & detection Flame detector response Flame on = 1 second max Flame off = as specified in description of function Minimum flame current required 1uA @230Vac supply Hardware Options Environmental Conditions The P25 series of controls is available with Ambient temperature range -10oC to 70oC several factory selectable options. These Humidity 90% RH Maximum are shown in the adjacent diagram. “L” Lockout indication with reset (indication and reset are connected to CON5). operation “F” Fanned with optional 2-wire APS (CON4). Connections details “1” Single stage direct burner ignition (valves connected to CON1). “2” Pilot + main burner (all valves connected to CON1). “1+1” Pilot + main burner (pilot valve connected to CON1, main valve to CON3). “X” External isolating transformer for flame detector (connected to CON3). This option can only be selected in conjunction with option “1” or “2”. If this option is not specified then a jumper link must be connected to CON3 in place of the transformer. (See below.) Electrical Supply Options The control can be specified with either: • A fixed phase-earth relationship (the earth is bonded to one of the phases in the property electrical installation). In this case the flame detector circuit is phase sensitive. • An external 230V:230V 2VA transformer with earthed secondary. In this case the flame detector circuit is completely isolated from the mains supply and is non-phase sensitive. (This is for applications where the phase-earth relationship is floating or fixed at mid-rail). • An external link which creates a phase-earth relationship (fitted instead of the external transformer). Timing and Control Options Pre-purge time: 1.5 - 50 seconds Lockout type volatile or non-volatile Wait or pre-purge time for atmospheric burners, is the time from the start signal, to energisation of the ignition device. Appliance type fanned or atmospheric Pre-purge time for fanned appliances, is the time from the air pressure switch closing (signaling sufficient airflow) to energisation APS type 2 or 3 terminal or not present of the ignition device. Number of ignition attempts: 1 - 5 Pre-ignition time: 1.0 - 50 seconds A number of ignition attempts can be programmed into the control Pre-ignition time is the time following the pre-purge period when to allow it to try again if the burner does not light on the first the ignition device, alone, is energised. attempt. Ignition time: 1.0 - 50 seconds Minimum ignition required Ignition time is the time that the ignition device is energised for Tells the control to remove the means of ignition immediately a during ignition, whilst the flame detector signals an absence of flame is detected (or to leave it energised until the end of the flame. ignition period). Safety time: 1.0 - 50 seconds Ignition type: 3/5/12/25/50 Hz Safety time is the time that GV1 is energised for during ignition, whilst the flame detector signals an absence of flame. On flame loss the following events can be programmed to occur: Lock-out Safety GV1 time: 0.3 - 3.0 seconds If the control is programmed to have lock-out on flame loss, then it Safety GV1 time is the time that GV1 remains energised for, after will immediately go to lock-out…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Pactrol Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Pactrol Microgas P25F FTL/V24 427001/V24

Frequently Asked Questions

Where can I source the Pactrol Microgas P25F FTL/V24 control in your region?

3G Electric supplies the Pactrol Microgas P25F FTL/V24 control (PAC44030) for delivery to your location. We handle all import logistics, customs customs clearance, and USD invoicing. Contact us for lead times and quotation.

What is the lead time for Pactrol Microgas P25F control delivery?

Lead time varies based on stock availability and logistics routing. 3G Electric sources this control unit available to order with shipping to your region. For your specific timeline and delivery schedule, please request a quotation — we manage all clearance and last-mile logistics.

What are the main electrical specifications of the Pactrol Microgas P25F FTL/V24?

The Microgas P25F FTL/V24 operates on 230 V AC (±10% to −15%), 50–60 Hz (±3 Hz), with 15 VA power consumption. Spark energy exceeds 4 mJ per W.H.I.T.B. standard, internal 2 A HPC fuse (20 mm), and adjustable pre-purge/ignition times from 1.0–50 seconds. CE certified.

Used in

Common applications for Pactrol
Industrial gas burners 10–60 kW — Pactrol Box P 16 FI and Control Box P 16 DIS spark-ignition controllers with 12 kV output and EN 298 approval
Atmospheric heating boilers — CSS01 12SJ control housing with integrated time and flame relays for safe ignition sequencing and flame detection
Forced-air burner retrofits — Pactrol connector assemblies (Molex, 10-terminal, P25) for panel rewiring and fuel-valve interface upgrades
Microgas fuel-valve integration — P25 connectors with resistors (e.g., GV2 96121) for seamless connection to Microgas proportional and solenoid valves
OEM control-panel assembly — Pactrol ignition modules and connectors for custom burner-control panels in packaged heating and combustion equipment
Plant-floor equipment replacement — Spare connectors and control housings stocked in Singapore for same-day delivery to maintenance teams across Southeast Asia

Pactrol Products

3G Electric supplies Pactrol controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Microgas P25F V20 427001/V20
Pactrol
Microgas P25F V20 427001/V20
Microgas P25F FMV 427001/V12
Pactrol
Microgas P25F FMV 427001/V12
Box P 16 B/AFL 402701/V02
Pactrol
Box P 16 B/AFL 402701/V02
Box P 16 D 402901
Pactrol
Box P 16 D 402901
Box 4049 S ref 404901
Pactrol
Box 4049 S ref 404901
Box CSS01 24 RE ref 406700 V02
Pactrol
Box CSS01 24 RE ref 406700 V02

More from Pactrol

View all Pactrol parts
CSS 2 PRTV01 box reference 429103/V01
Pactrol
CSS 2 PRTV01 box reference 429103/V01
Housing CSS01 12SJ (SP) V11 reference 404700 V11
Pactrol
Housing CSS01 12SJ (SP) V11 reference 404700 V11
CSS 2 STV01 housing reference 429100/V01
Pactrol
CSS 2 STV01 housing reference 429100/V01
Pactrol
Pactrol
Digital vacuum pump 241 L/MIN
Pactrol
Pactrol
UVV cells Pactrol 110V reference 401600
Pactrol
Pactrol
Box CSS01 12S 404700/V02 (without wiring base)
Pactrol
Pactrol
Molex connector 7 pins
Pactrol
Pactrol
Exterior plate PolarPad black 609x914x76 mm