Datasheet Content
P16 Range
Fully proven Full
Sequence Controls
technology factfile
The P16 range is a complete family of fully
proven, full sequence controls designed to
meet the needs of appliance manufacturers.
All controls are fully approved to EN 298
and meet all the essential requirement of
the Gas Appliance Directive.
The P16 range of full sequence controls is
ideal for use in atmospheric and forced
draught appliances, with either single or 2
stage ignition sequences. The family
consists of both volatile and non-volatile
lockout versions and has an integral spark
ignition generator for operation in dual or
single electrode applications.
The P16 range has a well proven
track record and, over the years, has
become an industry standard, with its high-
impact, flame retardant housing, screw
connectors and wide variety
of variants.
Typical applications
• Combination Boilers
• Condensing Boilers
• Heating Boilers
• Water Heaters
• Warm Air Heaters
• Radiant Tube Heaters
key features
• CE Certified to EN298
• Well-proven range of controls
• Integral spark and flame detection
• Single or dual electrode operation
• Volatile or non-volatile lockout functions
• Atmospheric or fanned applications
• Single or 2 stage ignition sequences
• Strong, flame retardant enclosure
• Non-reversible, screw based connector
P16D Dual Stage Ignition, Air Pressure Switch
Proving, Electrical Reset Lockout
Note: The sequence chart for P16DI and P16DIS is as shown above.
Wiring for P16DI is as dual probe operation P16D only. Wiring for
P16DIS is as single probe operation P16D only
P16F Dual Stage Ignition, Air Pressure Switch
Proving, Manual Reset Lockout
Note: The sequence chart for P16F1 is as shown above.
Wiring for P16F1 is as dual probe operation P16F only
To keep abreast of current developments, controls may be subject
to change without notice. Such changes may affect the accuracy
of information contained in this data-sheet, and the manufacturers
advice should be sought if any problems arise.
A division of White-Rodgers
Pactrol Controls LimitedUnit 3, Three Sisters Enterprise Park, Antler Court, Ashton-in-Makerfield, Wigan WN4 8DU, UK
P16 option chart
Technical specification
Electrical Supply Voltage: 230V + 10% - 15% except P16AV 110V + 10% - 15%
Frequency: 50 Hz
Consumption: 5VA
Ambient Temperature -5Þc to + 60Þc
Humidity Maximum of 95% RH
Ignition Generator Open circuit voltage at 30pF 12KV
Energy Output 10MJ
Spark Gap Tolerance 2.5mm to 4.00mm
H.T. Lead Length 1 Metre Maximum
Switching Capacity 1st Stage Gas Valve GV1 1A Maximum
2nd Stage Gas Valve GV2 1A Maximum
Air Pressure Switch Proving Relay 1A Maximum
dimensions
Overall Dimensions
140mm x 100mm x 54mm
Sequence of Operation and Wiring Details for
P16 Range
The following options are intended for use on atmospheric applications where air pressure switch proving is not required.
P16A & P16AV Single Stage Ignition
Electrical Reset Lockout
P16B Dual Stage1 Ignition
Electrical Reset Lockout
P16H Dual Stage1 Ignition Manual Reset Lockout
The following options have an integral air pressure switch proving relay and are
intended for use on forced draught burner applications.
P16C Single Stage Ignition Air Pressure Switch Proving Electrical
SYSTEME ALLUMAGE
CARACTÉRISTIQUES TECHNIQUES
Générateur d'étincelles
Alimentation
Tension àl'électrode 180V
Tension 230V +/-10%
Impédance à50 Hz 4MQ
( 110 V pour le P16AV) Courant de court circuit 50 µA
Fréquence 50 Hz Tension de sortie 12 kV
Consommation électrique 5V A Energie de sortie 10MJ
Fusible interne 1A Ecartement Electrodes 2. 5mm à4mm
Longueur max. câble HT 1m
Détection de flamme Pouvoir de coupure
Principe de détection courant d'ionisation Groupe Vanne 1A
Courant d'ionisation nominal 5µA Pressostat d'air 5A
Courant minimum 1 µA Environnement
Fusible externe àprévoir 5A
Temps de réponse Température de fonctionnement -5/+60°C
Humidité maximum 95 %
Apparition de la flamme 100ms
Dimensions 140x 100x 54
Disparition de la flamme 75ms
PROBLEMES EVENTUELS
CD Couper l'alimentation électrique avant toute intervention sur le boîtier. Toute intervention sur le boîtier doit être fait par un
personnel qualifié.
Afin d'obtenir une bonne détection de flamme il est essentiel que le neutre de l'installation électrique soit raccordé àla terre. Si ce n'est
pas le cas, il est conseillé d'installer un transformateur d'isolement et de raccorder une phase àla terre.
Si le problème persiste, remplacer le coffret de sécurité. N'essayer pas de réparer ou de ressouder les composants du circuit imprimé,
cela entraînera la perte de la garantie constructeur.
Les boîtiers défectueux doivent être retourné en bon état général avec leur emballage d'origine chez l'importateur des produits. Il est
bon de préciser en retournant l'appareil les conditions de fonctionnements (application, câblage électrique ...).
La détection par cellule ultra violet ne peut être effectué que par une cellule UV PACTROL. Aucune autre marque de cellule n'est com
patible avec les boîtiers PACTROL. Les cellules Pactrol ne fonctionnent pas avec d'autres marques de boîtiers de sécurité. Si les boî
tiers peuvent fonctionner avec des tensions de courant inférieure à230 V, les cellules UV n'acceptent qu'une variation de 15 % de la
tension nominale.
Les produits peuvent évoluer selon les développements et les normes. Les informations de cette notice peuvent ne plus être d'actuaté.
Le constructeur et l'importateur sont àvotre service pour vous fournir ces informations supplémentaires .
En cas de gros changements, une nouvelle notice sera diffusée.