We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Honeywell Amplifier R7852 A 1001 2/3 sec - Controls
HoneywellControls

Honeywell Amplifier R7852 A 1001 2/3 sec

The Honeywell R7852 is a controls amplifier designed for flame-failure detection systems with a response time of 2/3 second, ensuring rapid shutdown in combustion applications where safety-critical monitoring is…

SKU 3G-CBM-04246

Also listed as: HON 12210 · HON-12210

Brand
Honeywell
Item
Amplifier R7852 A 1001 2/3 sec
Category
Controls
UNSPSC
39121026 — Control power transformer
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Honeywell
type
Amplifier
model
R7852
flame failure response time
2/3 sec

Datasheet Content

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules SPECIFICATION DATA The R7849A,B Ultraviolet Flame Amplifiers are solid state plug-in amplifiers that respond to an ultraviolet signal from a C7027, C7035 or C7044 Ultraviolet Flame Detector to indicate the presence of flame when used with 7800 SERIES Relay Modules. The R7851B Optical Flame Amplifiers are solid state plug-in amplifiers that respond to optical signals from C7927 and C7962 Flame Detectors to indicate the presence of flame when used with 7800 SERIES Relay Modules. The R7851C Dynamic Self-Check Optical Flame Amplifier is a solid state plug-in amplifier that responds to ultraviolet signals from C7961E,F Dynamic Shutter-Check ultraviolet flame detectors to indicate the presence of flame when used with 7800 SERIES and R7140 Relay Modules. The R7852A,B Infrared Flame Amplifiers are solid state plug- in amplifiers that respond to an infrared signal from a C7915 Infrared Flame Detector to indicate the presence of flame when used with 7800 SERIES and R7140 Relay Modules. The R7861A Self-Check Ultraviolet Flame Amplifier is a solid state plug-in amplifier that responds to an ultraviolet signal from a C7061A Self-Check Ultraviolet Flame Detector to APPLICATION indicate the presence of flame when used with 7800 SERIES Relay Modules. The R7824C Rectification Flame Amplifier is a solid state plug-in amplifier that responds to a rectified signal from a The R7886A Dynamic Self-Check Ultraviolet Amplifier is a C7024E,F Self-Check Ultraviolet Flame Detector to indicate solid state plug-in amplifier that responds to a pulsed direct the presence of flame when used with an RM7824 Relay current signal from a C7076A,C Ultraviolet Flame Detector Module. with adjustable sensitivity to indicate the presence of flame when used with 7800 SERIES Relay Modules. The R7847A,B Rectification Flame Amplifiers are solid state plug-in amplifiers that respond to a rectified signal from a rectification type flame detector to indicate the presence of FEATURES flame when used with 7800 SERIES Relay Modules. • Flame failure response time (FFRT) of 0.8 or 1 second; The R7847C Self-Check Rectification Flame Amplifier is a or 2.0 or 3.0 seconds, depending on the amplifier and solid state plug-in amplifier that responds to a rectified signal relay module selected. See Table 1. from a C7012E,F Self-Check Ultraviolet Flame Detector to indicate the presence of flame when used with 7800 SERIES • Plug-in to 7800 SERIES Relay Module through printed Relay Modules. This is not European Community (CE) circuit board edge connector keyed for proper approved for EC7810, EC7820, EC/RM7830 or EC/RM7850 orientation. Relay Modules. • Flame signal test jacks measure amplifier flame signal voltage. The R7848A,B Infrared Flame Amplifiers are solid state plug-in amplifiers that respond to an infrared signal from a • 0.0 to 5.0 Vdc Flame signal strength reading range. C7015 Infrared Flame Detector to indicate the presence of flame when used with 7800 SERIES Relay Modules. 66-2034-04 R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 AMPLIFIERS FOR 7800 SERIES AND R7140 RELAY MODULES • Color coded label identifies flame detection type Table 1. Relay Module Flame Failure (see Table 2): Response Time (FFRT). — Green: rectification. Flame Failure Response Time (FFRT) — Red: infrared. Relay Module 0.8 or 1.0 second 2.0 or 3.0 seconds — Purple: ultraviolet. — Blue: pulsed rectification. EC7810, EC7820, 1.0 2.0 — White: optical. EC/RM7830, EC/RM7850 • R7847B, R7848B, R7849B, R7851B, R7852B Dynamic Ampli-Check® circuitry tests all flame amplifier EC/RM7823, 0.8 3.0 components 12 times per minute. The 7800 SERIES / EC/RM7885, R7140 Relay Module locks out on safety shutdown EC/RM7890, with amplifier failure. RM7895,6,7,8 RM7888, • R7824C, R7847C Dynamic Self-Check Rectification RM7838, Amplifier, R7851C Dynamic Self-Check Optical Flame RM7800, Amplifier, R7861 Self-Check Ultraviolet Flame EC/RM7840, R7140 Amplifier and R7886A Dynamic Self-Check Ultraviolet Amplifier test the detectors and all electronic RM7824 N/A 3.0 components in the flame detection system 12 times per minute. The 7800 SERIES and R7140 Relay Module Flame Signal (Volts dc): locks out on safety shutdown with flame detection Minimum Acceptable: 1.25 Vdc. system failure. Flame Signal Voltage Range (displayed on Keyboard Display Module or measured with a 1M ohm voltmeter plugged into NOTE: R7824C, Series 2 or greater, and R7847C, series 4 amplifier test jacks): 0.0 to 5.0 Vdc. or greater, pulse shutter when signal of 1.5 Vac is sensed. Environmental Ratings: Ambient Temperature: Operating: -40°F to 140°F (-40°C to 60°C). SPECIFICATIONS Storage: -40°F to 150°F (-40°C to 65°C). Humidity: Operating 85% rh continuous, noncondensing. Vibration: Continuous 0.5G environment. Models: Flame Detection Systems (see Table 2): Dimensions: See Fig. 1. Rectification: R7824C for use with C7024E,F Solid State Ultraviolet Detectors. – + R7847A,B for use with flame rods, rectifying photocells or S C7012A,C Solid State Ultraviolet Detectors. R7847C for use with C7012E,F Solid State Ultraviolet FLAME AMPLIFIER Detectors. 3 Infrared: (76) R7848A,B for use with C7015 Infrared (lead sulfide) Detector. R7852A,B for use with C7915 Infrared (lead sulfide) Detector. 3/8 (9) Ultraviolet: R7849A,B for use with C7027/C7035/C7044 Minipeeper 3-9/16 (91) 7/8 (23) Ultraviolet Detectors. R7851C for use with C7961E,F Flame Detectors. M11460 R7861A for use with C7061A,F Ultraviolet Detector. R7886A for use with C7076A,D Ultraviolet Detectors with Fig. 1. Flame amplifier dimensions in in. (mm). adjustable sensitivity. Optical: Weight: 2.5 oz (71 g), unpacked. R7851B for use with C7927 and C7962 Flame Detectors. Approvals: Flame Failure Response Time : See Table 1. Underwriters Laboratories Inc. Listed: File no. MP268, guide no. MCCZZ: R7847A, R7847B, R7847C, R7861A, R7886A, R7848A, R7848B, R7849A, R7849B, R7851B. Underwriters Laboratories Inc. Component Recognized: File no. MP268, guide no. MCCZZ: R7824C. Canadian Standards Association Certified: LR95329-3. Factory Mutual Approved: Report 1V9A0.AF. Swiss Re (formerly Industrial Risk Insurers) Acceptable. NOTE: EN298 Approved: When these amplifiers are used with an EC7810, EC7820, EC/RM7830, or EC/RM7850 Relay Module. 66-2034—04 2 R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 AMPLIFIERS FOR 7800 SERIES AND R7140 RELAY MODULES Accessories: Flame Simulators: Rectification: Part no. 123514A. CAUTION Ultraviolet: Part no. 203659.…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Honeywell Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Honeywell R7852 is a controls amplifier designed for flame-failure detection systems with a response time of 2/3 second, ensuring rapid shutdown in combustion applications where safety-critical monitoring is essential.

Frequently Asked Questions

Where can I buy a Honeywell R7852 amplifier in your region?

3G Electric supplies the Honeywell R7852 controls amplifier for delivery to your location, your location, and nationwide. We handle customs documentation, USD invoicing, and full logistics support.

What is the lead time for the Honeywell R7852 A 1001?

Lead time is available on request. 3G Electric sources the R7852 amplifier directly and manages all import logistics and customs clearance to your region.

What response time does the R7852 amplifier provide for flame-failure detection?

The Honeywell R7852 has a 2/3 second response time, ensuring rapid shutdown in safety-critical flame-failure detection systems for burners and combustion equipment.

Used in

Common applications for Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

Honeywell Products

3G Electric supplies Honeywell controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Amplifier R7849 A 1023
Honeywell
Amplifier R7849 A 1023
Honeywell
Honeywell
Amplifier R 7861 A 1026
Honeywell
Honeywell
Amplifier R 7861 A 1034
Amplifier R 7847 B 1031 (replaces R7847B1056)
Honeywell
Amplifier R 7847 B 1031 (replaces R7847B1056)
Amplifier R7847 A 1033 (replaces R7847A1066)
Honeywell
Amplifier R7847 A 1033 (replaces R7847A1066)
Relay EC 7850 A 1072
Honeywell
Relay EC 7850 A 1072

More from Honeywell

View all Honeywell parts
Box S4565 C 1025 V01U
Honeywell
Box S4565 C 1025 V01U
Housing S4565 A 2050 U
Honeywell
Housing S4565 A 2050 U
Housing S4565 BF 1062 U
Honeywell
Housing S4565 BF 1062 U
Honeywell
Honeywell
ST7800 A 1013 prepurge
Honeywell
Honeywell
Pressure switch DWR1 0.2/1.6 bar
Honeywell
Honeywell
Prepurge ST7800 A 1005
Honeywell
Honeywell
KT COMB 50 (pair of flanges)
Honeywell
Honeywell
Pressure switch DWR6 0.5/6 bar