We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Image not available
HoneywellControls

Honeywell Pressure switch DWR3 0.2/2.5 bar

Honeywell DWR3 pressure switch monitors or limits pressure in industrial systems with a 0.2–2.5 bar range and 0.1 bar switching differential. Rated to 16 bar maximum with G 1/2 and G 1/4 connections, it achieves SIL…

SKU 3G-CBM-04269

Also listed as: HON 32308 · HON-32308

Brand
Honeywell
Item
Pressure switch DWR3 0.2/2.5 bar
Category
Controls
UNSPSC
39121026 — Control power transformer
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Honeywell
function
pressure monitor or pressure limiter
standard
SIL 2 according IEC 61508-2
connections
G 1/2 external thread, G 1/4 internal thread
max pressure
16 bar
pressure range
0.2–2.5 bar
switching differential
0.1 bar

Datasheet Content

DWR Pressure monitors Especially suitable as a pressure monitor This pressure switch is "of special construction" or pressure limiter for fuel gases (DVGW and has been tested with 2 million operating Worksheet G 260) and liquid fuels (e.g. fuel oil), cycles. TÜV and DVGW tests exists. as well as for steam systems according to TRD 604 and hot-water systems to DIN EN12828, systems in accordance to DIN EN12952-11 and DIN EN12953-9. The DWR is used to monitor maximum and minimum pressures. SIL 2 according IEC 61508-2 DWR625 Technical data Component tested for Steam Systems according to TRD 604 Hot water Systems according to DIN EN12828 Pressure connection External thread G 1/2 (pressure gauge Fuel gases DVGW Worksheet G 260 connection) to DIN 16 288 and internal thread Pressure tank DIN EN764-7 G 1/4 to ISO 228 Part 1 (for gas applications internal thread permissible only up to 4 bar). Function Pressure monitor or pressure limiter (with external interlock) Switching device Rugged housing (200) made of seawater- Direction of action For maximum and minimum pressure monitoring resistant diecast aluminium. (DWFS, SDBFS) Materials Sensor "of special construction" by testing with 2 million cycles. Pressure bellows: Material no. 1.4571 Sensor housing: Material no. 1.4104 Switch housing: GD AI Si 12 (DIN 1725) Mounting position Product Summary Vertically upright and horizontal. Ambient temperature at switching device Type Setting range Switching Maximum Dimen- –25 to +70°C, Medium temperature –25 to +70°C. The differential working sioned maximum medium temperature at the pressure (mean values) pressure drawing sensor must not exceed the permitted ambient temperature at the switching device. Temperatures may reach 85°C for short periods. Pressure monitors without differential adjustment p. 21 + 22 Higher medium temperatures are possible DWR06 0.1…0.6 bar 0.04 bar 6 bar 1 + 15 provided the above limit values for the switching device are ensured by suitable measures DWR1 0.2…1.6 bar 0.06 bar (e.g. siphon). DWR3 0.2…2.5 bar 0.1 bar 16 bar 1 + 18 Mounting DWR6 0.5…6 bar 0.2 bar Directly on the pressure line (pressure gauge DWR625 0.5…6 bar 0.25 bar 25 bar 1 + 17 connection) or on a flat surface with two 4 mm DWR16 3…16 bar 0.5 bar Ø screws. DWR25 4…25 bar 1.0 bar 63 bar 1 + 16 Calibration DWR40 8…40 bar 1.3 bar The DWR series is calibrated for rising pressure. This means that the adjustable switching pressure on the scale corresponds to the switching point at Switching differential adjustable rising pressure. The reset point is lower by the DWR06–203 0.1…0.6 bar 0.08…0.5 bar 6 bar 1 + 15 amount of the switching differential. (See also page 17, 2. Calibration at upper switching point). DWR1–203 0.2…1.6 bar 0.15…0.6 bar In version ...-203 the switching differential is DWR3–203 0.2…2.5 bar 0.17…1.2 bar 16 bar 1 + 18 adjustable. The basic calibration is maintained. DWR6–203 0.5…6 bar 0.3…1.4 bar Bursting pressure DWR625–203 0.5…6 bar 0.4…2.5 bar 25 bar 1 + 17 For all types ≥ 100 bar, verified by TÜV test. DWR16–203 3…16 bar 0.75…3.15 bar Switching differential For values see Product DWR25–203 4…25 bar 1.3…6.0 bar 63 bar 1 + 16 Summary. DWR40–203 8…40 bar 2.3…6.6 bar Contact arrangement Single pole changeover switch. Switching 250 VAC 250 VDC 24 VDC capacity (ohm) (ind) (ohm) (ohm) Normal 8A 5A 0.3 A 8A Degree of protection IP 54 according to DIN 40 050 50 Mechanical pressure switches Tested to PE Directive 97/23/EC DBS Pressure monitors / pressure limiters In many aspects, safety-engineered pressure monitoring lines for short-circuit and line limiters offer a higher degree of safety compared break and therefore offers an additional safety with normal pressure switches and are therefore advantage – even in non-Ex-zones. For especially suitable for chemical process Ex-applications, the isolating amplifier must be engineering and thermal installations in which installed outside the Ex-zone. The lines between safety is an especially critical factor in pressure the isolating amplifier and the pressure switch monitoring. Pressure switches can also be used are monitored for short-circuit and line break. in Ex- zones (zone 0, 1, 2 and 20, 21, 22) and, in all cases, require an isolating amplifier. SIL 2 according IEC 61508-2 DWAM6-576 The isolating amplifier is also responsible for Technical data Safety requirements for pressure limiters Pressure limiters "of special construction" (DBS) must fulfil additional safety requirements, i.e. breakage Greater safety · in process engineering and chemical or leakage in the mechanical part of the sensor must lead to shutdown to the safe side. The pressure installations, limitermust respond as if the system pressure had already exceeded the maximum limit. The control · in gas and liquid gas installations circuit for the pressure limiter must also be considered from the point of view of safety, as short-circuits Basic features: in the supply lines or other faults in the control current circuit can lead to dangerous conditions. – "Of special construction" according to VdTÜV Memorandum "Pressure 100" – Line break and short-circuit monitoring- Switching element with positive opening operation and gold-plated contacts between pressure switch and isolating The microswitch is equipped with positive opening operation. Rather than transmitting the plunger force amplifier via a spring, which is the usual method with most microswitches, this newly developed microswitch has – Suitable for Ex areas (zone 0, 1 & 2 or 20, 21 & 22) (explosion protection Ex-ia) an additional lever which transmits the movements of the pressure bellows positively to the contact lever. – Degree of protection IP 65 If the spring breaks, the contact lever is moved directly. – Plastic-coated housing (chemical version) Options: Line break and short-circuit monitoring in the control circuit – Limiter with internal interlock The resistor connected in series with the switching contact limits the current to a defined value with the Type-specific features: switch closed. In the event of short-circuit in the area between the isolating amplifier and the series – Self-monitoring sensors resistor, the current rises above the predetermined limit value, the relay of the isolating amplifier drops – Positive opening microswitches out, the output current circuit is interrupted and thus the safe condition is achieved. In the event of a line – Gold-plated contacts – TÜV, DVGW component tests break, the current flow is interrupted, the relay drops to the safe side and interrupts the output current circuit (safety sequence). Furthermore, the isolating amplifier is designed so that, if faults occur in the electronics (conductor interruption, component defect etc.) and in the resulting situations, the safe shutdown condition is assured. These characteristics of the safety-engineered isolating amplifier, including line break and short-circuit monitoring, satisfy the requirements of DIN/VDE 0660, Part 209. Connection diagram For pressure monitoring in Ex areas, the isolating amplifier must be installed outside the Ex-zone. The pressure limiter has an intrinsically safe control current circuit (Ex-ia). This arrangement is suitable for zones 0, 1 and 2, 20, 21 and 22. M e c h a n i c a l p r e s s u r e s w i t c h e s 51 Tested to PE Directive 97/23/EC Pressure switches…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Honeywell Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Honeywell DWR3 pressure switch monitors or limits pressure in industrial systems with a 0.2–2.5 bar range and 0.1 bar switching differential. Rated to 16 bar maximum with G 1/2 and G 1/4 connections, it achieves SIL 2 certification per IEC 61508-2 for safety-critical applications.

Frequently Asked Questions

Where can I buy a Honeywell DWR3 pressure switch in your region?

3G Electric supplies the Honeywell DWR3 (HON32308) with delivery to your location. We handle all customs documentation and logistics. Lead time on request — contact our team for availability and USD pricing.

What is the lead time for the Honeywell DWR3 pressure switch?

Lead time varies by current stock status. 3G Electric sources this SIL 2 certified switch available to order for delivery to your region. Contact us with your required delivery date for a firm timeline and quotation.

Is the Honeywell DWR3 suitable for safety-critical applications?

Yes. The DWR3 achieves SIL 2 certification per IEC 61508-2, making it suitable for safety-critical pressure monitoring and limiting in industrial systems. It operates from 0.2–2.5 bar with 0.1 bar switching differential and G 1/2 and G 1/4 connections rated to 16 bar maximum.

Used in

Common applications for Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

Honeywell Products

3G Electric supplies Honeywell controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Honeywell
Honeywell
Pressure switch DWR16 3/16 bar
Pressure switch RT 1A 0.8/5bar
Danfoss
Pressure switch RT 1A 0.8/5bar
This Honeywell 5000 Series pressure switch is designed for machine tool applications requiring liquid and corrosion resistance. It monitors and controls pressure within a range of 0.5 psi to 150 psi. The switch features a 1/8-27" MNPT pressure connection type. Typical uses include industrial hydraulic and pneumatic systems where reliable pressure switching is needed
Honeywell
This Honeywell 5000 Series pressure switch is designed for machine tool applications requiring liquid and corrosion resistance. It monitors and controls pressure within a range of 0.5 psi to 150 psi. The switch features a 1/8-27" MNPT pressure connection type. Typical uses include industrial hydraulic and pneumatic systems where reliable pressure switching is needed
This Honeywell pressure switch is designed for industrial machine tool applications requiring liquid and corrosion resistance. It monitors pressure in hydraulic or pneumatic systems, triggering an electrical signal when pressure reaches a set point between 0.5 psi and 150 psi. The switch features a 1/8-27" MNPT pressure connection for easy installation
Honeywell
This Honeywell pressure switch is designed for industrial machine tool applications requiring liquid and corrosion resistance. It monitors pressure in hydraulic or pneumatic systems, triggering an electrical signal when pressure reaches a set point between 0.5 psi and 150 psi. The switch features a 1/8-27" MNPT pressure connection for easy installation
This Honeywell pressure switch is designed for machine tool applications requiring resistance to liquids and corrosive environments. It features a 1/8-27" MNPT pressure connection and operates over a pressure range of 0.5 to 150 psi. Typical uses include monitoring and controlling pressure in coolant systems and hydraulic circuits
Honeywell
This Honeywell pressure switch is designed for machine tool applications requiring resistance to liquids and corrosive environments. It features a 1/8-27" MNPT pressure connection and operates over a pressure range of 0.5 to 150 psi. Typical uses include monitoring and controlling pressure in coolant systems and hydraulic circuits
Barb-type pressure regulator with 5/32 in barbed connections for tubing. Control range 3 psi to 18 psi, maximum operating pressure 30 psi. Used in HVAC, combustion, and process control systems to regulate gas or air pressure
Honeywell
Barb-type pressure regulator with 5/32 in barbed connections for tubing. Control range 3 psi to 18 psi, maximum operating pressure 30 psi. Used in HVAC, combustion, and process control systems to regulate gas or air pressure

More from Honeywell

View all Honeywell parts
Box S4565 C 1025 V01U
Honeywell
Box S4565 C 1025 V01U
Housing S4565 A 2050 U
Honeywell
Housing S4565 A 2050 U
Housing S4565 BF 1062 U
Honeywell
Housing S4565 BF 1062 U
Honeywell
Honeywell
ST7800 A 1013 prepurge
Honeywell
Honeywell
Pressure switch DWR1 0.2/1.6 bar
Honeywell
Honeywell
Prepurge ST7800 A 1005
Honeywell
Honeywell
KT COMB 50 (pair of flanges)
Honeywell
Honeywell
Pressure switch DWR6 0.5/6 bar