Fantini Cosmi Remote relay transmitter for CH13 CH172DS - Switches & Thermostats
Fantini CosmiSwitches & Thermostats

Fantini Cosmi Remote relay transmitter for CH13 CH172DS

Fantini Cosmi remote relay transmitter converts thermostat commands for CH13 CH172DS systems, mounting on DIN rail at 6 modules with 230V 50Hz supply and 2VA power consumption. Ideal for HVAC control integration and…

SKU 3G-CBM-03686

Also listed as: FAN 54014 · FAN-54014

Brand
Fantini Cosmi
Item
Remote relay transmitter for CH13 CH172DS
Category
Switches & Thermostats
UNSPSC
39122229 — Temperature switch
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Fantini Cosmi
input
Thermostat commands
mounting
DIN rail 6 modules
supply voltage
230V 50Hz
power consumption
2VA

Datasheet Content

3G-CBM-03686 Actionneur CH172D de barre DIN Application et emploi Il est possible de raccorder un seul thermostat CH130AR à plusieurs actionneurs, de façon à commander plus d’un fan-coil simultanément, avec deux câbles uniquement (voir plus bas). Fixation et raccordement Vérification du fonctionnement L’appareil est prévu pour l’installation à encas- Pour l‘utilisation du thermostat CH130AR trement (à l’intérieur de fan-coil, tableaux spé- consulter le manuel spécifique d’instructions. ciaux ou autres logements adéquats). L‘installation doit être effectuée par du person- • Vérifier que l’actionneur soit correctement nel qualifié selon les normes EN en vigueur. raccordé au thermostat. La distance entre l‘actionneur et le transmet- • Alimenter l’actionneur en le raccordant au ré- teur ne doit pas être supérieure à 100 m. Rac- seau électrique. corder les fils à la plaque à bornes du socle • Effectuer, sur le thermostat, la commutation selon les schémas reportés ci-après. de la vitesse du moteur de ventilation (3 relais) Si on dispose d’une installation à deux tubes, et de la commande valves (2 relais) et vérifier raccorder uniquement la valve 1 (contact en- leur commutation effective. tre les bornes C et V1). Avec une installation 4 tubes, la valve 1 est dédiée au chauffage et la valve 2 (entre C et V2) au rafraîchissement. ATTENTION! Avant d’effectuer toute interven- tion sur l’appareil, vérifier avoir déconnecté les câbles de connexion au réseau électrique. Raccordements électriques Raccorder plusieurs actionneurs à un thermostat CH130R Un CH130AR peut commander jusqu’à cinq fan-coil simultanément, en utilisant seulement Valim.E.V. A deux câbles pour se raccorder aux action- neurs. Un de ces actionneurs devra être un Valim.E.V. B CH172D, tandis que les autres, au maximum Moteur quatre, seront des CH172DS. Les appareils devront être raccordés selon le 230 Vca schéma suivant: CH172DS CH172DS CH130AR A B AB AB BA BA BA CH172D CH172DS CH172DS Caractéristiques techniques de l’actionneur Alimentation 230V 50 Hz Dimensions Conteneur 6 modules de barre DIN 106x93x42mm Puissance absorbée 2VA Conforme aux direc- 2006/95/CE, Entrée Commandes thermostat tives suivantes 2004/108/CE, 1993/68/CE Caractéristiques 5(3)A250 V~ Répondant aux EN60730-1 sortie relais normes Contacts en com- 2 sorties valves mutation libres de tension Contacts en com- 3 sorties contacts moteur mutation à tension de réseau Conteneur IP00 (degré de pollution 2) Software classe A Température maxi- T45 mum Déconnexion type 1B (micro-déconnexion) Tension impulsive 4000V Type de montage Barre DIN

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fantini Cosmi Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Fantini Cosmi remote relay transmitter converts thermostat commands for CH13 CH172DS systems, mounting on DIN rail at 6 modules with 230V 50Hz supply and 2VA power consumption. Ideal for HVAC control integration and building management applications.

Frequently Asked Questions

Where can I order the Fantini Cosmi FAN54014 relay transmitter in your region?

3G Electric supplies the Fantini Cosmi FAN54014 remote relay transmitter with delivery to your location. We handle all customs import documentation and customs processing. Request a quote with your delivery address for lead time confirmation.

What is the lead time and shipping for the FAN54014 to your region?

Lead time on request. 3G Electric manages full logistics and customs clearance for delivery throughout your region. Confirm your site location (your location, your location, or other region) when ordering for accurate delivery schedule.

What are the electrical specifications of the FAN54014 relay transmitter?

The Fantini Cosmi FAN54014 operates at 230V 50Hz with 2VA power consumption. It mounts on DIN rail as 6 modules and converts thermostat commands for CH13 CH172DS systems, suitable for HVAC control and building management integration.

Used in

Common applications for Fantini Cosmi
Oil-fired boiler burner control — Fantini Cosmi ambient thermostat C16I and pressure switch B12HNY for fuel-pump lockout and room-temperature feedback.
Pneumatic compressor load management — B12DN or B13CN pressure switch for unload-valve control and tank cutout in 5–150 bar air systems.
Hydronic heating-plant commissioning — B12GNY and B12CRNY switches for pump-discharge and low-pressure monitoring in chilled-water and hot-water loops.
Industrial steam and hot-water vessel safety — B12HNY high-pressure switch and A96D/A95B level regulators for water-level and overpressure interlocks.
Thermal-storage tank management — A95B and A96D liquid-level regulators with 15-meter cable reach for boiler-makeup and expansion-tank applications.
Portable pump and pressure-test equipment — B12DN with adjustable differential for mobile hydraulic-circuit monitoring and component proof-pressure validation.

Fantini Cosmi Products

3G Electric supplies Fantini Cosmi switches & thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Ambient thermostat fan CH130ARR2 (remote relay)
Fantini Cosmi
Ambient thermostat fan CH130ARR2 (remote relay)
Room thermostat fan CH130RR (remote relay)
Fantini Cosmi
Room thermostat fan CH130RR (remote relay)
RF transmitter/receiver type CH173D
Fantini Cosmi
RF transmitter/receiver type CH173D
Satronic
Satronic
Radio frequency transmitter CH13 CH172DRF
Fantini Cosmi
Fantini Cosmi
Ambient thermostat fan CH130ARFR (radio frequency)
Fantini Cosmi
Fantini Cosmi
Room thermostat fan CH130RFR (radio frequency)

More from Fantini Cosmi

View all Fantini Cosmi parts
Ambient thermostat CH115RF white
Fantini Cosmi
Ambient thermostat CH115RF white
Fantini Cosmi
Fantini Cosmi
Immersion aquastat external adjustment 10/90°C C03A3
Fantini Cosmi
Fantini Cosmi
Branching box KBE3
Fantini Cosmi
Fantini Cosmi
Room thermostat CH111 silver
Fantini Cosmi
Fantini Cosmi
Daily program C58C silver
Fantini Cosmi
Fantini Cosmi
Immersion aquastat fixed setting 100°C C06A3M
Fantini Cosmi
Fantini Cosmi
Immersion aquastat external adjustment 40/120°C C03B3
Fantini Cosmi
Fantini Cosmi
Spacing bar, 1m, PVC KJSSP