We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Fantini Cosmi Built-in hygrostat 1 outlet L22EM1A 230V - Switches & Thermostats
Fantini CosmiSwitches & Thermostats

Fantini Cosmi Built-in hygrostat 1 outlet L22EM1A 230V

Fantini Cosmi flush-mount hygrostat with single-pole relay output for humidity control in HVAC and building automation. Measures 0-100 RH% with ±0.7 RH% accuracy at 230 Vac, IP55 protected. Ideal for wall-mounted…

SKU 3G-CBM-03658

Also listed as: FAN 24048 · FAN-24048

Brand
Fantini Cosmi
Item
Built-in hygrostat 1 outlet L22EM1A 230V
Category
Switches & Thermostats
UNSPSC
39122229 — Temperature switch
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Fantini Cosmi
type
Flush-mount hygrostat
outlets
1
accuracy
±0.7 RH%
output type
single-pole relay
power supply
230 Vac
measuring range
0-100 RH%
protection degree
IP55

Datasheet Content

L22 Humidistats, flush mounting (panel) For humidification or dehumidification systems with 1 outlet Dimensions (mm) Sensor Num out- Power supply Measuring Resolution Measuring Degree of puts range accuracy protection RH% RH% (0-100 RH%) L22EI1A 1 probe LS160A excluded 12Vac/dc 1 0 - 100 1 <± 0.7 IP55 L22EM1A 1 probe LS160A excluded 230 Vac ELECTRICAL CHARACTERISTICS Output on single-pole relay in deviation. Contact rating 16(4)A 240 Vac. Power consumption 2W. REGULATIONS AND APPROVALS Compliant with EN60730-1, EN60730-2-9, EN55022 (CLASS B), EN50082-1. INSTALLATION Flush mounting (panel) with fixing brackets. OPERATION Type of control: can operate in ON/OFF or PID mode. ON/OFF control: in ON/OFF mode the output is ON or OFF depending on the input humidity, setpoint (1SP) and hysteresis value (1HY). The hysteresis indicates the amplitude of the deviation of the setpoint humidity to reactivate the output. PID control: in PID mode the output is ON for a fraction of cycle time 1CT. The cycle time characterises the dynamics of the system to be controlled and influences the accuracy of the control. Proportional control. Integrative proportional control. 14 FEATURES Configurable parameters: „ dehumidification or humidification function by assigning positive or negative sign to the differential respectively; „ minimum or maximum setpoint limits; „ ON or OFF status of the output in the event of a defective probe. Operating temperature -10 to 50°C. Degree of protection IP55 (if correctly installed in panel with sealing gasket). ACCESSORIES LS160A LT312U Probe RH% Transformer scale range from 0 to 100 %RH 230/12V 50-60Hz 3VA L 15

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fantini Cosmi Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Fantini Cosmi flush-mount hygrostat with single-pole relay output for humidity control in HVAC and building automation. Measures 0-100 RH% with ±0.7 RH% accuracy at 230 Vac, IP55 protected. Ideal for wall-mounted indoor humidity management applications.

Frequently Asked Questions

Where can I buy the Fantini Cosmi L22EM1A hygrostat in your region?

Order from 3G Electric. We deliver to your location, handle all customs customs clearance, and manage import logistics. Lead time on request — contact our sales team for availability and USD invoicing.

What is the lead time for the Fantini Cosmi L22EM1A?

Lead time varies based on current stock and import schedules. 3G Electric handles all logistics to your region, including customs processing. Request a quote for delivery timeline and freight costs to your location.

What humidity range does the L22EM1A measure?

The Fantini Cosmi L22EM1A measures 0-100 RH% (relative humidity) with ±0.7 RH% accuracy. It features a single-pole relay output, 230 Vac supply, and IP55 protection for wall-mounted indoor HVAC and building automation control.

Used in

Common applications for Fantini Cosmi
Oil-fired boiler burner control — Fantini Cosmi ambient thermostat C16I and pressure switch B12HNY for fuel-pump lockout and room-temperature feedback.
Pneumatic compressor load management — B12DN or B13CN pressure switch for unload-valve control and tank cutout in 5–150 bar air systems.
Hydronic heating-plant commissioning — B12GNY and B12CRNY switches for pump-discharge and low-pressure monitoring in chilled-water and hot-water loops.
Industrial steam and hot-water vessel safety — B12HNY high-pressure switch and A96D/A95B level regulators for water-level and overpressure interlocks.
Thermal-storage tank management — A95B and A96D liquid-level regulators with 15-meter cable reach for boiler-makeup and expansion-tank applications.
Portable pump and pressure-test equipment — B12DN with adjustable differential for mobile hydraulic-circuit monitoring and component proof-pressure validation.

Fantini Cosmi Products

3G Electric supplies Fantini Cosmi switches & thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Embedded hygrostat 1 outlet L22EI1A 12VAC/DC
Fantini Cosmi
Embedded hygrostat 1 outlet L22EI1A 12VAC/DC
Fantini Cosmi
Fantini Cosmi
Hygrostat DIN rail 1 outlet L23EM1A 230V
Fantini Cosmi
Fantini Cosmi
Wall hygrometer 2 outlets L24EM2 230V
ON/OFF thermostat 1 outlet L02DI1B 12VAC/DC
Fantini Cosmi
ON/OFF thermostat 1 outlet L02DI1B 12VAC/DC
ON/OFF thermostat 1 outlet L02CI1B 12VAC/DC
Fantini Cosmi
ON/OFF thermostat 1 outlet L02CI1B 12VAC/DC
ON/OFF thermostat 2 outlets L02DM2 115/230V
Fantini Cosmi
ON/OFF thermostat 2 outlets L02DM2 115/230V

More from Fantini Cosmi

View all Fantini Cosmi parts
Ambient thermostat CH115RF white
Fantini Cosmi
Ambient thermostat CH115RF white
Fantini Cosmi
Fantini Cosmi
Immersion aquastat external adjustment 10/90°C C03A3
Fantini Cosmi
Fantini Cosmi
Branching box KBE3
Fantini Cosmi
Fantini Cosmi
Room thermostat CH111 silver
Fantini Cosmi
Fantini Cosmi
Daily program C58C silver
Fantini Cosmi
Fantini Cosmi
Immersion aquastat fixed setting 100°C C06A3M
Fantini Cosmi
Fantini Cosmi
Immersion aquastat external adjustment 40/120°C C03B3
Fantini Cosmi
Fantini Cosmi
Spacing bar, 1m, PVC KJSSP