Fantini Cosmi ON/OFF thermostat 1 outlet L02DI1B 12VAC/DC - Switches & Thermostats
Fantini CosmiSwitches & Thermostats

Fantini Cosmi ON/OFF thermostat 1 outlet L02DI1B 12VAC/DC

The Fantini Cosmi L02DI1B is a single-outlet ON/OFF thermostat for HVAC and industrial temperature control applications. It features a 1 NTC 10K probe with ±0.3°C accuracy and 0.1°C resolution, operating on 12…

SKU 3G-CBM-03645

Also listed as: FAN 24014 · FAN-24014

Brand
Fantini Cosmi
Item
ON/OFF thermostat 1 outlet L02DI1B 12VAC/DC
Category
Switches & Thermostats
UNSPSC
39122229 — Temperature switch
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Fantini Cosmi
sensor
1 NTC 10K probe LS130
outputs
1
power supply
12Vac/dc
resolution c
0.1 (-19.9-99.9), 1
probe accuracy c
±0.3°C (-40-100), ±1°C
measuring range c
-40 to 105
protection degree
IP55

Datasheet Content

■ Pendant la phase d’autotest, appuyer sur les touches + , et les garder appuyées jusqu’à ce que l’appareil affiche 0AD. MODE D’EMPLOI ■ Avec les touches et sélectionner 0AD ou SAD: 0AD permet la calibration du 0 en introduisant une correction constante sur 2DF -19.9...19.9° Différentiel de température par rapport à 1SP. Le point de consigne de la sortie auxiliaire correspond à 1SP+2DF toute l’échelle de mesure. SAD permet la calibration de la partie haute de l’échelle de mesure avec une correction proportionnelle Nous vous remercions d’avoir choisi un produit Fantini Cosmi. Pour que votre instrument soit le plus sûr et le plus performant ON entre le point de calibration et le 0. ON possible, il est indispensable d’en lire attentivement le mode d’emploi. ■ Appuyer sur pour afficher la valeur et agir avec + ou pour faire coïncider la valeur lue avec celle mesurée par 2SM=REL DESCRIPTION INDICATIONS l’instrument de référence; OFF OFF ■ Pour quitter la calibration, appuyer sur la touche . OUT1 Sortie canal 1 2DF>0 1SP+2DF+2HY T[°] 1SP+2DF-2HY 2DF<0 T[°] PARAMETRES DE CONFIGURATION 1SP 1SP+2DF 1SP+2DF 1SP OUT2 Sortie canal 2 Contrôle ON/OFF en réfrigération. Point de Contrôle ON/OFF en chauffage. Point de ■ Pour accéder au menu de configuration des paramètres, presser pendant 5 secondes les touches + . OAU=THR consigne 2 relatif au point de consigne 1 consigne 2 relatif au point de consigne 1 L1 Modification point de consigne 1 ■ Avec les touches ou sélectionner le paramètre à modifier. (OAU=THR, 2CH=REF) (OAU=THR, 2CH=HEA) ■ Presser la touche pour afficher la valeur. L2 Modification point de consigne 2 2CH REF; HEA Modalité de régulation réfrigération (REF) ou chauffage (HEA) pour la sortie auxiliaire. ■ Tout en maintenant la touche pressée, agir avec les touches ou pour fixer la valeur désirée. Alarme ■ La nouvelle valeur est mémorisée et le paramètre suivant est affiché lorsque l’on cesse de presser la touche 2HY 0...19.9° Différentiel OFF/ON en mode 2. Avec 2HY=0 la sortie reste éteinte ■ Pour sortir du réglage, presser la touche ou attendre 30 secondes. Fig.1 — Panneau avant 2T0 0...30min Temps minimum d’arrêt. Touche augmentation / Modification point de consigne 2 Après un arrêt, la sortie 2 reste désactivée pendant 2T0 minutes indépendamment de la valeur Touche Info / Enter. PAR PLAGE DE DESCRIPTION de la température. Modification point de consigne 1 / diminution. Touche sortie / Stand-by. MESURE INSTALLATION 2T1 0...30min Temps minimum d’activation SCL 1°C; Échelle de lecture. (voir table des caractéristiques entrée) Après la mise en marche, la sortie 2 reste activée pendant 2T1 minutes indépendamment de la 2°C; Attention: si la valeur de SCL est modifiée, les paramètres concernant les températures absolues ■ Introduire l’instrument dans un trou de 71x29 mm. valeur de la température. °F et relatives (SPL, SPH, 1SP, 1HY etc..) doivent absolument être reconfigurés. ■ Effectuer les raccordements électriques en suivant les indications du paragraphe “schémas de raccordement”. Pour réduire les effets des perturbations électromagnétiques, éloigner des conducteurs de puissance les câbles des sondes et de signal.…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Fantini Cosmi Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Fantini Cosmi L02DI1B is a single-outlet ON/OFF thermostat for HVAC and industrial temperature control applications. It features a 1 NTC 10K probe with ±0.3°C accuracy and 0.1°C resolution, operating on 12 VAC/DC. The unit delivers IP55 protection for reliable performance in demanding environments.

Frequently Asked Questions

Where can I buy the Fantini Cosmi L02DI1B thermostat in your region?

Order from 3G Electric. We deliver to your location with full customs customs clearance and USD invoicing. Lead time on request—contact our team for availability and quotation.

What is the temperature accuracy and measurement range of this thermostat?

The L02DI1B features ±0.3°C accuracy across -40 to 100°C, with 0.1°C resolution in the -19.9 to 99.9°C range. The NTC 10K probe (LS130) measures up to 105°C maximum.

Is this thermostat suitable for industrial HVAC applications?

Yes. The L02DI1B is rated IP55 for protection in demanding environments. It operates on 12 VAC/DC with 1 relay outlet, making it ideal for ON/OFF temperature control in HVAC and industrial systems.

Used in

Common applications for Fantini Cosmi
Oil-fired boiler burner control — Fantini Cosmi ambient thermostat C16I and pressure switch B12HNY for fuel-pump lockout and room-temperature feedback.
Pneumatic compressor load management — B12DN or B13CN pressure switch for unload-valve control and tank cutout in 5–150 bar air systems.
Hydronic heating-plant commissioning — B12GNY and B12CRNY switches for pump-discharge and low-pressure monitoring in chilled-water and hot-water loops.
Industrial steam and hot-water vessel safety — B12HNY high-pressure switch and A96D/A95B level regulators for water-level and overpressure interlocks.
Thermal-storage tank management — A95B and A96D liquid-level regulators with 15-meter cable reach for boiler-makeup and expansion-tank applications.
Portable pump and pressure-test equipment — B12DN with adjustable differential for mobile hydraulic-circuit monitoring and component proof-pressure validation.

Fantini Cosmi Products

3G Electric supplies Fantini Cosmi switches & thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
ON/OFF thermostat 1 outlet L02CI1B 12VAC/DC
Fantini Cosmi
ON/OFF thermostat 1 outlet L02CI1B 12VAC/DC
ON/OFF thermostat 2 outlets L02CI2B 12VAC/DC
Fantini Cosmi
ON/OFF thermostat 2 outlets L02CI2B 12VAC/DC
ON/OFF thermostat 1 output L02BI1A 12VAC/DC
Fantini Cosmi
ON/OFF thermostat 1 output L02BI1A 12VAC/DC
ON/OFF thermostat 1 output L03BI1A 12VAC/DC
Fantini Cosmi
ON/OFF thermostat 1 output L03BI1A 12VAC/DC
ON/OFF thermostat 2 outputs L02DI2B 12VAC/DC
Fantini Cosmi
ON/OFF thermostat 2 outputs L02DI2B 12VAC/DC
ON/OFF thermostat 1 output L02DM1 115/230V
Fantini Cosmi
ON/OFF thermostat 1 output L02DM1 115/230V

More from Fantini Cosmi

View all Fantini Cosmi parts
Ambient thermostat CH115RF white
Fantini Cosmi
Ambient thermostat CH115RF white
Fantini Cosmi
Fantini Cosmi
Immersion aquastat external adjustment 10/90°C C03A3
Fantini Cosmi
Fantini Cosmi
Branching box KBE3
Fantini Cosmi
Fantini Cosmi
Room thermostat CH111 silver
Fantini Cosmi
Fantini Cosmi
Daily program C58C silver
Fantini Cosmi
Fantini Cosmi
Immersion aquastat fixed setting 100°C C06A3M
Fantini Cosmi
Fantini Cosmi
Immersion aquastat external adjustment 40/120°C C03B3
Fantini Cosmi
Fantini Cosmi
Spacing bar, 1m, PVC KJSSP