| Voltage | 220–240 V AC |
| Frequency | 50/60 Hz |
| Pump Type | AUV |
| Gear Capacity | Per flow curve (reference required) |
| Model Variants | AUV 47L 9877 6P 0700, AUV 47R 9876 6P 0700 |
| Nozzle Outlets | 2 possible nozzle outlet positions |
| Installation Type | Single-line or dual-line |
| Fuel Compatibility | Domestic heating oil, HVO, B100 (biofuel blend up to 100% per DIN SPEC 51603-6 and EN 14214), kerosene |
| Pressure Regulation | Pressure regulation with inline solenoid cutoff |
| Solenoid Valve Type | Normally closed inline solenoid with return check valve |
| Standards Compliance | DIN SPEC 51603-6, EN 14214 |
| Pump Purging Dual Tube | Flat on regulator piston |
| Pump Purging Single Tube | Manual venting via pressure tap until air evacuation complete |
| Rotation Direction Options | R (clockwise) or L (counterclockwise, viewed from shaft) |
| Nozzle Outlet Configuration | Right or left selectable |
| Compatible Replacement Models | SUNTEC AS 47, AL 35, ALE 35 |
| Dual Tube Installation Feature | Bypass plug in return port |
| Nozzle Line Discharge Function | Yes (for nozzles with cutoff function and minimum 4 bar opening pressure) |
| Single Tube Installation Feature | Bypass plug removal and return orifice plugging required |