FBR X FGP 44.22 LX TL SI is a two-stage light-oil diesel burner designed for low-NOx combustion applications. Operating between 237–522 kW with fuel flow of 20–44 kg/h and emissions under 120 mg/m³ NOx, it suits…

SKU 3G-FBR-00075

Brand
FBR
Item
X FGP 44.22 LX TL SI
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
52 kg
stage
Serie low nox
fuel type
Light oil
nozzle mm
288
fan motor w
0.74
power kw max
522
power kw min
237
flow kg h max
44
flow kg h min
20
ip protection
IP 40
noisiness dba
77
electrical supply
3
power supply info
3~400V, 1N~230V 50Hz
current absorption a
2
thermal power mcal h
147/204-450
nominal electric power w
1.1
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS AT TWO STEPS SK070101_A_en PRESSURE (LX SERIES) FGP 44.22-LX - FGP 55.22-LX Light-oil burners at two steps pressure - Low NOx (NOx < 120 mg/kWh). Composed by: die-cast aluminum body, fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance.. Complete of nozzle, flange and gasket for installation on generator, flexible pipes, line filter. Fig. FGP 44.22-LX Fig. FGP 55.22-LX FGP 44.22-LX - FGP 55.22-LX LIGHT-OIL BURNERS AT TWO STEPS PRESSURE (LX SERIES) SK070101_A_en TECHNICAL DATA MODEL FGP 44.22-LX Flow min.1°st. / min. 2°st. - max. 2°st. * [kg/h] 14.4/20-44 Thermal power min.1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 147/204-450 Thermal power min.1°st. / min. 2°st. - max. 2°st. * [kW] 171/237-522 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 NOx ** [mg/kWh] < 120:class 3 (EN267) Intermitted working operation (min. 1 stop every 24 hours) two steps pressure Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 1.1 Fan motor [kW] 0.74 Nominal current absorption [A] 2 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness min. - max. *** [dBA] 77 *Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** To obtain the NOx emissions as low as declared, it will be necessary to couple the burner to boilers suitable for this purpose: three-pass boilers, condensing boilers and any direct exhaust generator with a thermal load no higher than 1.1 MW/m³. *** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746). OPERATING RANGE DIAGRAM FGP 44.22-LX [mbar] 13 11 9 7 5 3 1 -1 0 100 200 300 400 500 600 700 [kW] Fig. X฀=฀Thermal power฀Y฀=฀Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FGP 44.22-LX - FGP 55.22-LX LIGHT-OIL BURNERS AT TWO STEPS SK070101_A_en PRESSURE (LX SERIES) TECHNICAL DATA MODEL FGP 55.22-LX Flow min.1°st. / min. 2°st. - max. 2°st. * [kg/h] 23.4/30-55 Thermal power min.1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 239/306-561 Thermal power min.1°st. / min. 2°st. - max. 2°st. * [kW] 277/355-652 Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 NOx ** [mg/kWh] < 120:class 3 (EN267) Intermitted working operation (min. 1 stop every 24 hours) two steps pressure Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 1.7 Fan motor [kW] 1.5 Nominal current absorption [A] 3 Alimentazione elettrica: 3~400V, 1N~230V - 50Hz Power supply: IP 40 Noisiness min. - max. *** [dBA] 78 Burner weight **** [kg] 52 *Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** To obtain the NOx emissions as low as declared, it will be necessary to couple the burner to boilers suitable for this purpose: three-pass boilers, condensing boilers and any direct exhaust generator with a thermal load no higher than 1.1 MW/m³. *** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746). **** Only for burner FGP 55.22-LX TL version. OPERATING RANGE DIAGRAM FGP 55.22-LX [mbar] 13 11 9 7 5 3 1 -1 0 100 200 300 400 500 600 700 [kW] Fig. X฀=฀Thermal power฀Y฀=฀Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non- compliance, contact the manufacturer. FGP 44.22-LX - FGP 55.22-LX LIGHT-OIL BURNERS AT TWO STEPS SK070101_A_en PRESSURE (LX SERIES) DIMENSIONS [MM] I F H D G E A B TC - TL* C Fig. Dimensions฀FGP 44.22-LX MODEL A B C D E F G H I FGP 44.22-LX 187 330 557 130 416 100 23 200 207 * See "flame tube length" DIMENSIONS [MM] TL* Fig. Dimensions฀FGP 55.22-LX MODEL A B C D E F G FGP 55.22-LX 187 362 170 160 623 416 18 * See "flame tube length" FGP 44.22-LX - FGP 55.22-LX LIGHT-OIL BURNERS AT TWO STEPS SK070101_A_en PRESSURE (LX SERIES) BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L max M N min N* N max FGP 44.22-LX mm 205 226 M10 160 160 180 FGP 55.22-LX mm 310 368 M12 170 180 250 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** FGP 44.22-LX mm 288 373 FGP 55.22-LX mm 238 323 ** For different flame lengths, please contact our Technical-Sales Department. FGP 44.22-LX - FGP 55.22-LX LIGHT-OIL BURNERS AT TWO STEPS SK070101_A_en PRESSURE (LX SERIES) BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 2 1 Fig. Burner…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR X FGP 44.22 LX TL SI is a two-stage light-oil diesel burner designed for low-NOx combustion applications. Operating between 237–522 kW with fuel flow of 20–44 kg/h and emissions under 120 mg/m³ NOx, it suits industrial heating systems requiring efficient, regulated firing with reduced environmental impact.

Frequently Asked Questions

Where can I source the FBR X FGP 44.22 LX TL SI diesel burner worldwide?

3G Electric is an authorised distributor of FBR burners. We handle procurement, logistics, and customs for worldwide delivery. Contact us for availability and lead times on the X FGP 44.22 LX TL SI.

What are the lead time and shipping options for this FBR diesel burner?

Lead time depends on current stock and destination. 3G Electric manages logistics globally and coordinates with carriers to deliver to your facility. Contact us with your location for a shipping estimate.

What are the power output and emissions specifications of the X FGP 44.22 LX TL SI?

The burner operates at 237–522 kW with fuel flow 20–44 kg/h. NOx emissions are below 120 mg/m³, meeting low-NOx combustion standards. It features two-stage pressure modulation for efficient industrial heating.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
X FGP 44.22 LXTC SI
FBR
X FGP 44.22 LXTC SI
FGP 75/2 LX TL SI
FBR
FGP 75/2 LX TL SI
FGP 75/2 LX TC SI
FBR
FGP 75/2 LX TC SI
FGP 160/2 LX TL SI
FBR
FGP 160/2 LX TL SI
FGP 75/2 TL SI
FBR
FGP 75/2 TL SI
FBR
FBR
FGP 44.22 LX TC

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL