Goods are offered EXW Singapore — collection from our Singapore facility.

3G Electric
NEXTTEQ NX-1000 Water Vapor (H2O) Gas Detection Tube, 10-Pack - Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
NEXTTEQGas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps

NEXTTEQ NX-1000 Water Vapor (H2O) Gas Detection Tube, 10-Pack

The NEXTTEQ NX-1000 Detector Tube (MPN NX805) is a gas detection tube for water vapor (H2O), supplied in a 10-pack for use in NEXTTEQ NX-1000 pumps. It measures water vapor concentrations from 20 to 160 mg/m3.

SKU 3G-OTH-602121

Also listed as: NX 805 · NX-805

Brand
NEXTTEQ
Item
NX-1000 Water Vapor
Part Number
NX805
Category
Gas Detection Tubes For Use In NEXTTEQ NX-1000 Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

NEXTTEQ
Manufacturer Part Number
NX805
Type
H2O, Gas Detection Tube, Water Vapor ( H2O ), 10 PK

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Ask a question

Request a Quote

Ask a question

NEXTTEQ Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The NEXTTEQ NX-1000 Detector Tube (MPN NX805) is a gas detection tube for water vapor (H2O), supplied in a 10-pack for use in NEXTTEQ NX-1000 pumps. It measures water vapor concentrations from 20 to 160 mg/m3.

Frequently Asked Questions

What is the NEXTTEQ NX-1000 detector tube used for?

The NEXTTEQ NX-1000 detector tube (MPN NX805) measures water vapor (H2O) concentrations in industrial gas streams. It is designed for use with NEXTTEQ NX-1000 pumps and is commonly applied in process monitoring, environmental compliance, and quality control across chemical, petrochemical, and HVAC applications.

What are the specifications of the NEXTTEQ NX-1000 H2O detector tube?

The NEXTTEQ NX-1000 detector tube (MPN NX805) detects water vapor (H2O) over a range of 20 to 160 mg/m3. It is supplied in a 10-pack and is intended for use with NEXTTEQ NX-1000 pumps. Each tube provides a single measurement for spot-checking moisture levels in gas samples.

Where to buy NEXTTEQ NX-1000 detector tubes worldwide?

3G Electric supplies NEXTTEQ NX-1000 detector tubes (MPN NX805) worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this 10-pack of water vapor detection tubes.

How to use the NEXTTEQ NX-1000 detector tube for water vapor measurement?

To measure water vapor, break off both tips of the NEXTTEQ NX-1000 tube, insert it into the NX-1000 pump, and draw a sample according to the pump instructions. The tube's color change indicates H2O concentration. Always follow the manufacturer's manual for stroke count and ambient conditions to ensure accurate readings.

Not sure this is the right part? Photo-identify it→

NEXTTEQ Products

3G Electric supplies NEXTTEQ gas detection tubes for use in nextteq nx-1000 pumps. We supply genuine products and their technical documentation.

You might also need

Pump Accessories →Valves & Regulation →Motors & Drives →All Products →

Compatible alternatives & equivalents

Cross-referenced by specification & description
HONEYWELL
HONEYWELL
Calibration gas mixture containing 500 ppm hydrogen in air, supplied in a 103 L cylinder with CGA 600 connection. Used to verify and adjust the accuracy of portable gas detectors during routine safety checks
HONEYWELL
HONEYWELL
Calibration gas for portable gas detectors, supplied as a 34 L cylinder of 100% Nitrogen with a CGA C10 connection. Used to verify and adjust the accuracy of gas detection instruments in industrial environments
HONEYWELL
HONEYWELL
Calibration gas mixture of 10 ppm hydrogen cyanide in nitrogen, with ±10% accuracy. Supplied in a 58 L cylinder with CGA C10 fitting. Used for functional testing and calibration of portable gas detectors that sense hydrogen cyanide, typically with bump test stations
HONEYWELL
HONEYWELL
Calibration gas mixture of 10 ppm hydrogen sulfide in nitrogen, supplied in a 58-liter cylinder with a CGA C10 connection. Used to verify and adjust the response of portable gas detectors that sense hydrogen sulfide in industrial safety applications

More from NEXTTEQ

View all NEXTTEQ parts →
Gas detection tube for measuring ethylene glycol (C2H6O2) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Measurement range: 20 to 250 mg/m³. Supplied in a pack of 5 tubes
NEXTTEQ
Gas detection tube for measuring ethylene glycol (C2H6O2) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Measurement range: 20 to 250 mg/m³. Supplied in a pack of 5 tubes
Gas detection tube for use with NEXTTEQ NX-1000 pumps. Detects dimethylformamide (C3H7NO) with two measurement ranges: 1 to 15 ppm and 2 to 30 ppm. Features break-off tip for operation. Supplied in a pack of 10
NEXTTEQ
Gas detection tube for use with NEXTTEQ NX-1000 pumps. Detects dimethylformamide (C3H7NO) with two measurement ranges: 1 to 15 ppm and 2 to 30 ppm. Features break-off tip for operation. Supplied in a pack of 10
Gas detection tube for use with NEXTTEQ NX-1000 pumps. Detects isobutyl acetate (C6H12O2) in a range of 10 to 400 ppm. Supplied as a 10-pack of single-use tubes for colorimetric measurement in industrial environments such as chemical processing, painting, and solvent handling
NEXTTEQ
Gas detection tube for use with NEXTTEQ NX-1000 pumps. Detects isobutyl acetate (C6H12O2) in a range of 10 to 400 ppm. Supplied as a 10-pack of single-use tubes for colorimetric measurement in industrial environments such as chemical processing, painting, and solvent handling
Gas detection tube for measuring hydrogen selenide (H2Se) concentrations. Designed for use with NEXTTEQ NX-1000 pumps. Provides two measurement ranges: 1 to 120 ppm and 5 to 600 ppm. Supplied in a pack of 10 tubes. Suitable for industrial safety monitoring in environments where H2Se may be present
NEXTTEQ
Gas detection tube for measuring hydrogen selenide (H2Se) concentrations. Designed for use with NEXTTEQ NX-1000 pumps. Provides two measurement ranges: 1 to 120 ppm and 5 to 600 ppm. Supplied in a pack of 10 tubes. Suitable for industrial safety monitoring in environments where H2Se may be present
Gas detection tube for measuring cyclohexanol (C6H12O) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Detection range: 5 to 500 ppm. Supplied in a 10-pack
NEXTTEQ
Gas detection tube for measuring cyclohexanol (C6H12O) concentrations in air. Designed for use with NEXTTEQ NX-1000 pumps. Detection range: 5 to 500 ppm. Supplied in a 10-pack

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first