HONEYWELLCalibration Gases for Portable Gas Detectors

HONEYWELL Calibration Gas, H2S 10 ppm in Nitrogen, 58 L Cylinder, CGA C10

The HONEYWELL Calibration Gas: Nitrogen (SKU 610-0051-000, MPN 610-0051-000) is a calibration gas for portable gas detectors, featuring a Hydrogen Sulfide 10 ppm mixture in a nitrogen background. It has a 58 L…

SKU 3G-OTH-550026

Also listed as: 6100051000 · 610 0051 000

Brand
HONEYWELL
Item
Calibration Gas, H2S 10 ppm in Nitrogen, 58 L Cylinder, CGA C10
Part Number
610-0051-000
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

HONEYWELL
Manufacturer Part Number
610-0051-000
Type
H2S, Calibration Gas, Calibration Gas
CGA Number
CGA C10
Gas Mixture
Hydrogen Sulfide 10 ppm
Background Gas
Nitrogen
Cylinder Capacity
58 L

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HONEYWELL Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HONEYWELL Calibration Gas: Nitrogen (SKU 610-0051-000, MPN 610-0051-000) is a calibration gas for portable gas detectors, featuring a Hydrogen Sulfide 10 ppm mixture in a nitrogen background. It has a 58 L cylinder capacity and a CGA C10 connection. 3G Electric interprets this demand and delivers it across 14 industrial departments, with specialist depth in combustion, pumps and controls as an authorised distributor.

Frequently Asked Questions

What is HONEYWELL calibration gas 610-0051-000 used for?

This HONEYWELL calibration gas is used to verify and adjust the accuracy of portable gas detectors that sense hydrogen sulfide. The 10 ppm H2S mixture in a nitrogen background ensures reliable sensor response in industrial safety applications across oil & gas, chemical, and wastewater facilities.

What are the specifications of HONEYWELL calibration gas 610-0051-000?

The HONEYWELL calibration gas (MPN 610-0051-000) has a 58 L cylinder capacity with a CGA C10 connection. The gas mixture is Hydrogen Sulfide 10 ppm in a nitrogen background. It is designed for portable gas detector calibration and is supplied by 3G Electric.

Where to buy HONEYWELL calibration gas 610-0051-000 worldwide?

3G Electric supplies the HONEYWELL calibration gas 610-0051-000 to customers worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact us to order this calibration gas for your portable gas detectors.

How to use HONEYWELL calibration gas 610-0051-000 for gas detector calibration?

Attach the cylinder's CGA C10 connection to the regulator on your portable gas detector. Follow the detector manufacturer's calibration procedure, applying the 10 ppm H2S mixture at the specified flow rate. After calibration, close the valve and store the cylinder upright in a ventilated area.

Used in

Common applications for HONEYWELL
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits
Not sure this is the right part? Photo-identify it

HONEYWELL Products

3G Electric supplies HONEYWELL calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from HONEYWELL

View all HONEYWELL parts
HONEYWELL
HONEYWELL
Calibration gas mixture of 25 ppm nitric oxide in a nitrogen background, supplied in a 58 L cylinder with a CGA C10 connection. Used for verifying the accuracy of portable gas detectors that measure nitric oxide in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture of 100 ppm isobutylene in air, supplied in a 34 L cylinder with CGA C10 connection. Used for verifying the accuracy of portable gas detectors through routine bump testing and calibration
HONEYWELL
HONEYWELL
This calibration gas cylinder contains 5 ppm sulfur dioxide (SO2) in a nitrogen background, with +/-10% accuracy. It is intended for use with gas detection instruments to verify and adjust sensor response. The 58 L cylinder features a CGA C10 connection
HONEYWELL
HONEYWELL
Calibration gas mixture of 5 ppm chlorine in nitrogen background, supplied in a 58 L cylinder with CGA C10 fitting. Used to verify and adjust the accuracy of portable gas detectors that sense chlorine
HONEYWELL
HONEYWELL
Calibration gas containing 99.9% nitrogen in a 103 L cylinder with CGA 600 connection. Used for verifying and adjusting the accuracy of portable gas detectors with nitrogen sensors in industrial safety applications
HONEYWELL
HONEYWELL
Aerosol calibration gas containing 100 ppm carbon monoxide in an 11 L cylinder. Designed for verifying and calibrating GasAlert Series Model Carbon Monoxide sensors in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture containing 500 ppm hydrogen in air, supplied in a 103 L cylinder with CGA 600 connection. Used to verify and adjust the accuracy of portable gas detectors during routine safety checks
HONEYWELL
HONEYWELL
Calibration gas mixture containing 19% oxygen in a 58 L cylinder with CGA 600 connection. Used for verifying and adjusting the accuracy of portable gas detectors, particularly GasAlert Series Model Methane Sensors in industrial safety applications

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first