KDR LINE REACTORS KDRMA46L1E01 Input Line Reactor - Input Line Reactors
KDR LINE REACTORSInput Line Reactors

KDR LINE REACTORS KDRMA46L1E01 Input Line Reactor

The KDR LINE REACTORS Input Line Reactor (UL Type 1, MPN KDRMA46L1E01) is a Low Z reactor rated for 575/600V AC with a max output power of 1.5 hp and 17.2 W watts loss. 3G Electric interprets your demand for this…

SKU 3G-OTH-622444

Brand
KDR LINE REACTORS
Item
KDRMA46L1E01 Input Line Reactor
Category
Input Line Reactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

KDR LINE REACTORS
Manufacturer Part Number
KDRMA46L1E01
Type
Low Z
AC
575/600V
Watts Loss
17.2 W
Max Output Power
1.5 hp

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

KDR LINE REACTORS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KDR LINE REACTORS Input Line Reactor (UL Type 1, MPN KDRMA46L1E01) is a Low Z reactor rated for 575/600V AC with a max output power of 1.5 hp and 17.2 W watts loss. 3G Electric interprets your demand for this OEM-specified component, sourcing it across 14 industrial departments — with specialist depth in controls to support your application.

Frequently Asked Questions

What is a KDR line reactor used for?

A KDR line reactor protects variable frequency drives and motor controls from power line disturbances. It reduces harmonics, limits inrush current, and smooths voltage spikes in 575/600V AC industrial systems. 3G Electric sources this OEM-specified component across 14 departments, with specialist depth in controls to support your application.

What are the specifications of the KDRMA46L1E01 input line reactor?

The KDRMA46L1E01 is a UL Type 1, Low Z input line reactor rated for 575/600V AC with a max output power of 1.5 hp and 17.2 W watts loss. It is designed for industrial motor drive protection. 3G Electric supplies this KDR brand component globally.

Where to buy a KDR line reactor in worldwide?

3G Electric supplies the KDRMA46L1E01 input line reactor to worldwide locations. We handle full logistics, customs clearance, and delivery for this 575/600V AC, 1.5 hp component. Contact us for availability and lead time on this KDR brand reactor.

How to select the right input line reactor for a 575/600V AC drive?

Select a line reactor with voltage matching your drive (575/600V AC), impedance type (Low Z for general use), and power rating at or above the motor's 1.5 hp. Verify watts loss (17.2 W) for thermal management. 3G Electric can help interpret your demand and source the correct KDR component.

KDR LINE REACTORS Products

3G Electric supplies KDR LINE REACTORS input line reactors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from KDR LINE REACTORS

View all KDR LINE REACTORS parts
Input line reactor for variable frequency drives and motor controls. Reduces harmonics, limits inrush current, and smooths voltage spikes. High Z type, 10 hp max output power, 208/240V AC, 91.8 W watts loss. UL Type 1 rated
KDR LINE REACTORS
Input line reactor for variable frequency drives and motor controls. Reduces harmonics, limits inrush current, and smooths voltage spikes. High Z type, 10 hp max output power, 208/240V AC, 91.8 W watts loss. UL Type 1 rated
Open-style high-impedance input line reactor rated for 460/480V AC, 540 A maximum output current, and 450 hp maximum output power. Used in motor drive systems to reduce harmonic distortion and protect against voltage spikes and current surges
KDR LINE REACTORS
Open-style high-impedance input line reactor rated for 460/480V AC, 540 A maximum output current, and 450 hp maximum output power. Used in motor drive systems to reduce harmonic distortion and protect against voltage spikes and current surges
Open-style input line reactor rated for 208/240V AC, 5 A output current max, and 0.75 hp max output power. High impedance design for harmonic mitigation and transient protection in motor drive systems
KDR LINE REACTORS
Open-style input line reactor rated for 208/240V AC, 5 A output current max, and 0.75 hp max output power. High impedance design for harmonic mitigation and transient protection in motor drive systems
Open-style input line reactor for AC motor drive systems. Rated for 460/480V AC, 35 A maximum output current, and 25 hp maximum output power. High impedance type designed to reduce harmonics and voltage transients in industrial automation, HVAC, and pump applications
KDR LINE REACTORS
Open-style input line reactor for AC motor drive systems. Rated for 460/480V AC, 35 A maximum output current, and 25 hp maximum output power. High impedance type designed to reduce harmonics and voltage transients in industrial automation, HVAC, and pump applications
Open-type input line reactor rated for 575/600V AC, 3.2 A maximum output current, and 1.5 hp maximum output power. High impedance design for harmonic filtering and voltage spike suppression in motor drive systems
KDR LINE REACTORS
Open-type input line reactor rated for 575/600V AC, 3.2 A maximum output current, and 1.5 hp maximum output power. High impedance design for harmonic filtering and voltage spike suppression in motor drive systems
This input line reactor is designed for use with variable frequency drives and motor controllers to mitigate harmonics, voltage spikes, and electrical noise. Rated for 460/480V AC, 2.3 A output current, and 1 hp maximum output power, it is suitable for industrial motor drive applications requiring low impedance
KDR LINE REACTORS
This input line reactor is designed for use with variable frequency drives and motor controllers to mitigate harmonics, voltage spikes, and electrical noise. Rated for 460/480V AC, 2.3 A output current, and 1 hp maximum output power, it is suitable for industrial motor drive applications requiring low impedance
KDR LINE REACTORS
KDR LINE REACTORS
Low impedance input line reactor for AC motor drives, rated 575/600V, 1,250 hp, with 1,493 W power loss. Open construction for panel mounting. Used to reduce harmonics and voltage transients in variable frequency drive systems
Open-style input line reactor rated for 460/480V AC systems with a maximum output current of 100 A and maximum output power of 75 hp. Designed to protect variable frequency drives and other equipment from power line harmonics, voltage spikes, and current distortion in industrial motor control systems
KDR LINE REACTORS
Open-style input line reactor rated for 460/480V AC systems with a maximum output current of 100 A and maximum output power of 75 hp. Designed to protect variable frequency drives and other equipment from power line harmonics, voltage spikes, and current distortion in industrial motor control systems