We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

KDR LINE REACTORS Input Line Reactor: Open, High Z, 600 hp Max Output Power, 460/480V AC - Input Line Reactors
KDR LINE REACTORSInput Line Reactors

KDR LINE REACTORS Input Line Reactor: Open, High Z, 600 hp Max Output Power, 460/480V AC

The KDR LINE REACTORS Input Line Reactor: Open (SKU 3G-OTH-622416, MPN KDRULS1H) is a High Z, 750 A Output Current - Max reactor designed for 460/480V AC systems with a 600 hp Max Output Power. 3G Electric interprets…

SKU 3G-OTH-622416

Brand
KDR LINE REACTORS
Item
Input Line Reactor: Open, High Z, 600 hp Max Output Power, 460/480V AC
Category
Input Line Reactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

KDR LINE REACTORS
Manufacturer Part Number
KDRULS1H
Type
High Z, 750 A Output Current - Max
AC
460/480V
Max Output Power
600 hp

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

KDR LINE REACTORS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KDR LINE REACTORS Input Line Reactor: Open (SKU 3G-OTH-622416, MPN KDRULS1H) is a High Z, 750 A Output Current - Max reactor designed for 460/480V AC systems with a 600 hp Max Output Power. 3G Electric interprets your demand and sources this genuine industrial component across 14 departments, with specialist depth in combustion, pumps and controls as an authorised distributor.

Frequently Asked Questions

What is a KDR line reactor used for?

A KDR line reactor protects variable frequency drives and other sensitive equipment from power line disturbances such as harmonics, spikes, and voltage transients. It smooths incoming current and reduces electrical noise in 460/480V AC industrial systems, extending equipment life in motor control applications.

What are the specifications of the KDRULS1H input line reactor?

The KDRULS1H is an open-style, high-impedance input line reactor rated for 460/480V AC systems. It delivers a maximum output current of 750 A and supports up to 600 hp maximum output power. This KDR LINE REACTORS component is designed for heavy-duty industrial motor drive protection.

Where to buy KDR line reactors worldwide?

3G Electric supplies the KDRULS1H input line reactor to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. As a global industrial solutions provider, we source genuine KDR LINE REACTORS components and support your procurement across 14 technical departments.

How to select the right input line reactor for a 460V drive?

Select a reactor with voltage matching your system (460/480V AC) and an amp rating at least equal to the drive's input current. For a 600 hp drive, the KDRULS1H at 750 A provides high impedance to limit harmonics. Always verify the reactor's impedance percentage and thermal rating with the drive manufacturer's guidelines.

KDR LINE REACTORS Products

3G Electric supplies KDR LINE REACTORS input line reactors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from KDR LINE REACTORS

View all KDR LINE REACTORS parts
Input Line Reactor: Open, High Z, 200 hp Max Output Power, 460/480V AC, 240 A Output Current - Max (MPN KDRULJ1H)
KDR LINE REACTORS
Input Line Reactor: Open, High Z, 200 hp Max Output Power, 460/480V AC, 240 A Output Current - Max (MPN KDRULJ1H)
Input Line Reactor: Open, Low Z, 200 hp Max Output Power, 575/600V AC, 192 A Output Current - Max (MPN KDRULI42L)
KDR LINE REACTORS
Input Line Reactor: Open, Low Z, 200 hp Max Output Power, 575/600V AC, 192 A Output Current - Max (MPN KDRULI42L)
Input Line Reactor: Open, Low Z, 125 hp Max Output Power, 575/600V AC, 125 A Output Current - Max (MPN KDRULH43L)
KDR LINE REACTORS
Input Line Reactor: Open, Low Z, 125 hp Max Output Power, 575/600V AC, 125 A Output Current - Max (MPN KDRULH43L)
Input Line Reactor: UL Type 1, Low Z, 0.5 hp Max Output Power, 460/480V AC, 9.7 W Watts Loss (MPN KDRMA3L1E01)
KDR LINE REACTORS
Input Line Reactor: UL Type 1, Low Z, 0.5 hp Max Output Power, 460/480V AC, 9.7 W Watts Loss (MPN KDRMA3L1E01)
Input Line Reactor: Open, Low Z, 75 hp Max Output Power, 208/240V AC, 211 A Output Current - Max (MPN KDRULI23L)
KDR LINE REACTORS
Input Line Reactor: Open, Low Z, 75 hp Max Output Power, 208/240V AC, 211 A Output Current - Max (MPN KDRULI23L)
Input Line Reactor: UL Type 1, Low Z, 60 hp Max Output Power, 208/240V AC, 209 W Watts Loss (MPN KDRULH22LE01)
KDR LINE REACTORS
Input Line Reactor: UL Type 1, Low Z, 60 hp Max Output Power, 208/240V AC, 209 W Watts Loss (MPN KDRULH22LE01)
KDR LINE REACTORS
KDR LINE REACTORS
Input Line Reactor: Open, High Z, 1,500 hp Max Output Power, 575/600V AC, 2,985 W Watts Loss (MPN KDRULY42H)
Input Line Reactor: UL Type 1, High Z, 5.5 hp Max Output Power, 460/480V AC, 66.3 W Watts Loss (MPN KDRAA3H2E01)
KDR LINE REACTORS
Input Line Reactor: UL Type 1, High Z, 5.5 hp Max Output Power, 460/480V AC, 66.3 W Watts Loss (MPN KDRAA3H2E01)