Goods are offered EXW Singapore — collection from our Singapore facility.

3G Electric
KDR LINE REACTORS KDRAA3L2 Input Line Reactor, Low Z, 460/480V AC, 8.2 A, 5.5 hp - Input Line Reactors
KDR LINE REACTORSInput Line Reactors

KDR LINE REACTORS KDRAA3L2 Input Line Reactor, Low Z, 460/480V AC, 8.2 A, 5.5 hp

The KDR LINE REACTORS Input Line Reactor: Open (MPN KDRAA3L2) is a low-impedance input line reactor rated for 460/480V AC, with a maximum output power of 5.5 hp and a maximum output current of 8.2 A. 3G Electric…

SKU 3G-OTH-622343

Brand
KDR LINE REACTORS
Item
KDRAA3L2 Input Line Reactor, Low Z, 460/480V AC, 8.2 A, 5.5 hp
Part Number
KDRAA3L2
Category
Input Line Reactors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

KDR LINE REACTORS
Manufacturer Part Number
KDRAA3L2
Type
Low Z, 8.2 A Output Current - Max
AC
460/480V
Max Output Power
5.5 hp

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Ask a question

Request a Quote

Ask a question

KDR LINE REACTORS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The KDR LINE REACTORS Input Line Reactor: Open (MPN KDRAA3L2) is a low-impedance input line reactor rated for 460/480V AC, with a maximum output power of 5.5 hp and a maximum output current of 8.2 A. 3G Electric interprets your demand for this KDR component and delivers it as part of our broad industrial supply across 14 departments, with specialist depth in electrical and power transmission categories.

Frequently Asked Questions

What is a KDR input line reactor used for?

A KDR input line reactor protects variable frequency drives and motor systems from power line disturbances, harmonics, and voltage spikes. It smooths current flow and reduces electrical noise, extending equipment life in industrial automation, HVAC, and pumping applications.

What are the specifications of the KDRAA3L2 line reactor?

The KDRAA3L2 is a low-impedance open input line reactor rated for 460/480V AC, with a maximum output power of 5.5 hp and a maximum output current of 8.2 A. It is designed for use with drives and motors in 480V systems.

Where to buy KDR line reactors worldwide?

3G Electric supplies the KDRAA3L2 input line reactor to customers worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact us to order this KDR component for your electrical or power transmission needs.

How to select the right input line reactor for a 5.5 hp motor?

For a 5.5 hp motor at 460/480V AC, select a line reactor with a current rating at least equal to the motor's full-load current. The KDRAA3L2, rated for 8.2 A, matches this application. Always verify voltage and impedance requirements with the drive manufacturer.

Not sure this is the right part? Photo-identify it→

KDR LINE REACTORS Products

3G Electric supplies KDR LINE REACTORS input line reactors. We supply genuine products and their technical documentation.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

Cross-referenced by specification & description
Three-pole, three-phase definite purpose contactor with 3NO main pole contact form. Rated 30 A at 480V AC, with 440/480V AC coil voltage and maximum 600V AC. Quick-disconnect terminals. Used for switching HVACR loads such as compressors, condenser fans, and heating equipment
SQUARE D
Three-pole, three-phase definite purpose contactor with 3NO main pole contact form. Rated 30 A at 480V AC, with 440/480V AC coil voltage and maximum 600V AC. Quick-disconnect terminals. Used for switching HVACR loads such as compressors, condenser fans, and heating equipment
Three-phase, 4-pole non-reversing definite purpose contactor with 4 normally open main poles. Rated 40 A, 600V AC maximum, with 110/120V AC coil. Box lug terminals. Suitable for switching loads such as compressors, condenser fans, and other three-phase equipment in HVACR systems
SQUARE D
Three-phase, 4-pole non-reversing definite purpose contactor with 4 normally open main poles. Rated 40 A, 600V AC maximum, with 110/120V AC coil. Box lug terminals. Suitable for switching loads such as compressors, condenser fans, and other three-phase equipment in HVACR systems
Three-phase non-reversing definite purpose contactor with 3 poles and 3NO main pole contact form. Rated 40 A, coil voltage 220/208-240V AC, maximum voltage 600V AC. Box lug terminals. Suitable for switching HVACR and industrial equipment loads such as compressors, fan motors, and pumps
SQUARE D
Three-phase non-reversing definite purpose contactor with 3 poles and 3NO main pole contact form. Rated 40 A, coil voltage 220/208-240V AC, maximum voltage 600V AC. Box lug terminals. Suitable for switching HVACR and industrial equipment loads such as compressors, fan motors, and pumps
Three-phase definite purpose contactor with 4 normally open poles, rated 30 A and 277V AC coil. Maximum voltage 600V AC. Screw clamp terminals. Suitable for HVACR equipment such as air conditioning, refrigeration, and heating systems
SQUARE D
Three-phase definite purpose contactor with 4 normally open poles, rated 30 A and 277V AC coil. Maximum voltage 600V AC. Screw clamp terminals. Suitable for HVACR equipment such as air conditioning, refrigeration, and heating systems

More from KDR LINE REACTORS

View all KDR LINE REACTORS parts →
Open-style input line reactor rated for 460/480V AC with a maximum output current of 240 A and maximum output power of 200 hp. Provides high impedance to reduce harmonics, limit inrush current, and smooth voltage spikes in motor drive systems. Suitable for use with variable frequency drives and other industrial equipment requiring input line reactance
KDR LINE REACTORS
Open-style input line reactor rated for 460/480V AC with a maximum output current of 240 A and maximum output power of 200 hp. Provides high impedance to reduce harmonics, limit inrush current, and smooth voltage spikes in motor drive systems. Suitable for use with variable frequency drives and other industrial equipment requiring input line reactance
This input line reactor is designed for use with variable frequency drives and motor controllers to mitigate power line harmonics, surges, and voltage spikes. Rated for 208/240V AC, 12 A output current, and 3 hp maximum output power, it is suitable for 3-phase systems in industrial automation and HVAC applications
KDR LINE REACTORS
This input line reactor is designed for use with variable frequency drives and motor controllers to mitigate power line harmonics, surges, and voltage spikes. Rated for 208/240V AC, 12 A output current, and 3 hp maximum output power, it is suitable for 3-phase systems in industrial automation and HVAC applications
Open-style input line reactor rated for 460/480V AC systems. High impedance design with 750 A maximum output current and 600 hp maximum output power. Used to protect variable frequency drives and motor control equipment from power line disturbances such as harmonics, spikes, and voltage transients
KDR LINE REACTORS
Open-style input line reactor rated for 460/480V AC systems. High impedance design with 750 A maximum output current and 600 hp maximum output power. Used to protect variable frequency drives and motor control equipment from power line disturbances such as harmonics, spikes, and voltage transients
Open-style low-impedance input line reactor rated for 575/600V AC, 32 A maximum output current, and 30 hp maximum output power. Used with variable frequency drives and motor controllers to reduce harmonics, voltage spikes, and current distortion in industrial motor-drive applications
KDR LINE REACTORS
Open-style low-impedance input line reactor rated for 575/600V AC, 32 A maximum output current, and 30 hp maximum output power. Used with variable frequency drives and motor controllers to reduce harmonics, voltage spikes, and current distortion in industrial motor-drive applications
Low-impedance input line reactor for variable frequency drives and motor controllers. Rated 460/480V AC, 720 A maximum output current, 600 hp maximum output power. Open-style construction. Reduces harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and conveyor systems
KDR LINE REACTORS
Low-impedance input line reactor for variable frequency drives and motor controllers. Rated 460/480V AC, 720 A maximum output current, 600 hp maximum output power. Open-style construction. Reduces harmonics, voltage spikes, and current distortion in industrial automation, HVAC, pumping, and conveyor systems
This open-style input line reactor is designed for 575/600V AC systems with a maximum output current of 4.8 A and a maximum output power of 3 hp. It features low impedance construction to reduce harmonics, voltage spikes, and current distortion in motor drive applications. Typical uses include protecting variable frequency drives and motors in industrial automation, HVAC, and pumping systems
KDR LINE REACTORS
This open-style input line reactor is designed for 575/600V AC systems with a maximum output current of 4.8 A and a maximum output power of 3 hp. It features low impedance construction to reduce harmonics, voltage spikes, and current distortion in motor drive applications. Typical uses include protecting variable frequency drives and motors in industrial automation, HVAC, and pumping systems
High Z input line reactor for 460/480V AC systems, rated for 20 hp maximum output power with 108 W watts loss. Used in motor drive applications to reduce harmonics, limit inrush current, and smooth voltage spikes
KDR LINE REACTORS
High Z input line reactor for 460/480V AC systems, rated for 20 hp maximum output power with 108 W watts loss. Used in motor drive applications to reduce harmonics, limit inrush current, and smooth voltage spikes
This input line reactor is a High Z type rated for 600V AC, 2.1 A maximum output current, and 1 hp maximum output power. It is enclosed in a UL Type 1 housing for indoor use. The reactor conditions incoming AC power to motor drives, reducing harmonics and limiting voltage spikes
KDR LINE REACTORS
This input line reactor is a High Z type rated for 600V AC, 2.1 A maximum output current, and 1 hp maximum output power. It is enclosed in a UL Type 1 housing for indoor use. The reactor conditions incoming AC power to motor drives, reducing harmonics and limiting voltage spikes

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first