We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

HONEYWELL Calibration Gas - Calibration Gases for Portable Gas Detectors
HONEYWELLCalibration Gases for Portable Gas Detectors

HONEYWELL Calibration Gas

The HONEYWELL Calibration Gas: Nitrogen (MPN 610-0050-070) is a +/-10% accuracy calibration gas for gas detection instruments, supplied in a CGA 600 cylinder with a background gas of Nitrogen and a Carbon Monoxide…

SKU 3G-OTH-550594

Also listed as: 6100050070 · 610 0050 070

Brand
HONEYWELL
Item
Calibration Gas
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

HONEYWELL
Manufacturer Part Number
610-0050-070
Type
+/-10% Accuracy, CH4/CO/H2S/O2, Calibration Gas, CGA 600
CGA Number
CGA 600
Gas Mixture
Carbon Monoxide 50 ppm
For Use With
Gas Detection Instruments
Background Gas
Nitrogen

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HONEYWELL Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HONEYWELL Calibration Gas: Nitrogen (MPN 610-0050-070) is a +/-10% accuracy calibration gas for gas detection instruments, supplied in a CGA 600 cylinder with a background gas of Nitrogen and a Carbon Monoxide mixture of 50 ppm. 3G Electric interprets this demand and delivers it across 14 industrial departments, with specialist depth in combustion, pumps and controls as an authorised distributor.

Frequently Asked Questions

What is HONEYWELL Calibration Gas 610-0050-070 used for?

This HONEYWELL calibration gas is used to verify and adjust the accuracy of gas detection instruments. It contains a mixture of Carbon Monoxide 50 ppm in a Nitrogen background, supplied in a CGA 600 cylinder, ensuring reliable sensor performance in industrial safety applications.

What are the specifications of HONEYWELL Calibration Gas 610-0050-070?

The HONEYWELL Calibration Gas (MPN 610-0050-070) has +/-10% accuracy, a background gas of Nitrogen, and a gas mixture of Carbon Monoxide 50 ppm. It uses a CGA 600 connection and is designed for use with gas detection instruments.

Where to buy HONEYWELL Calibration Gas 610-0050-070 worldwide?

3G Electric supplies and delivers the HONEYWELL Calibration Gas 610-0050-070 worldwide. We handle full logistics and customs clearance, ensuring you receive the correct calibration gas for your gas detection instruments, regardless of your location.

How to use HONEYWELL Calibration Gas 610-0050-070?

Attach the CGA 600 cylinder to your gas detection instrument's regulator, then follow the manufacturer's calibration procedure. Apply the gas at the specified flow rate, allowing the sensor to stabilize before adjusting readings. Always use in a well-ventilated area and follow safety data sheet guidelines.

Used in

Common applications for HONEYWELL
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

HONEYWELL Products

3G Electric supplies HONEYWELL calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from HONEYWELL

View all HONEYWELL parts
HONEYWELL
HONEYWELL
Calibration gas mixture of 10 ppm ethylene oxide (C2H4O) in nitrogen background, supplied in a 58 L cylinder with CGA C10 fitting. Used for verifying and calibrating portable gas detectors that sense ethylene oxide
This calibration gas contains 10 ppm isobutylene in air, with +/-10% accuracy, supplied in a 34 L cylinder with a CGA 600 fitting. It is used to verify and adjust the response of portable gas detectors in bump test stations, ensuring proper sensor function for target gas detection
HONEYWELL
This calibration gas contains 10 ppm isobutylene in air, with +/-10% accuracy, supplied in a 34 L cylinder with a CGA 600 fitting. It is used to verify and adjust the response of portable gas detectors in bump test stations, ensuring proper sensor function for target gas detection
Calibration gas mixture containing 25 ppm hydrogen sulfide in nitrogen, with ±5% accuracy. Designed for use with GasAlert Series multi-gas monitors to verify and adjust sensor response. Fitted with a CGA 600 connection
HONEYWELL
Calibration gas mixture containing 25 ppm hydrogen sulfide in nitrogen, with ±5% accuracy. Designed for use with GasAlert Series multi-gas monitors to verify and adjust sensor response. Fitted with a CGA 600 connection
HONEYWELL
HONEYWELL
This calibration gas cylinder contains a mixture of 5 ppm sulfur dioxide in nitrogen, with a 58 L capacity and CGA C10 connection. It is used to verify and adjust the accuracy of portable gas detectors that sense sulfur dioxide in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture of 10 ppm hydrogen cyanide in nitrogen, with ±10% accuracy. Supplied in a 58 L cylinder with CGA C10 fitting. Used for functional testing and calibration of portable gas detectors that sense hydrogen cyanide, typically with bump test stations
This calibration gas cylinder contains 10 ppm hydrogen cyanide in a nitrogen background, with +/-10% accuracy. It is used to verify and calibrate gas detection instruments in industrial safety applications. The 58 L cylinder features a CGA 600 fitting
HONEYWELL
This calibration gas cylinder contains 10 ppm hydrogen cyanide in a nitrogen background, with +/-10% accuracy. It is used to verify and calibrate gas detection instruments in industrial safety applications. The 58 L cylinder features a CGA 600 fitting
HONEYWELL
HONEYWELL
This calibration gas cylinder contains 50 ppm ammonia in nitrogen with +/-5% accuracy and a CGA C10 fitting. The 58 L capacity is used for verifying and calibrating portable gas detection instruments in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture for portable gas detectors, containing Methane (2.5% LEL) and Oxygen 18% in a 58 L cylinder with CGA 600 connection. Used to verify and calibrate sensor response in industrial safety applications