EXW Singapore — collect or forward from our Singapore office.

3G Electric
HONEYWELL Calibration Gas: Chlorine 10 ppm in Nitrogen, 58 L Cylinder, CGA 600 - Calibration Gases for Portable Gas Detectors
HONEYWELLCalibration Gases for Portable Gas Detectors

HONEYWELL Calibration Gas: Chlorine 10 ppm in Nitrogen, 58 L Cylinder, CGA 600

The HONEYWELL Calibration Gas: Nitrogen is a +/-10% accuracy, Cl2 calibration gas for portable gas detectors, supplied in a 58 L cylinder with a CGA 600 fitting. It contains a Chlorine 10 ppm mixture in a Nitrogen…

SKU 3G-OTH-550759

Also listed as: 6000056000 · 600 0056 000

Brand
HONEYWELL
Item
Calibration Gas: Chlorine 10 ppm in Nitrogen, 58 L Cylinder, CGA 600
Part Number
600-0056-000
Category
Calibration Gases for Portable Gas Detectors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

HONEYWELL
Manufacturer Part Number
600-0056-000
Type
+/-10% Accuracy, Cl2, Calibration Gas
CGA Number
CGA 600
Gas Mixture
Chlorine 10 ppm
For Use With
Gas Detection Instruments
Background Gas
Nitrogen
Cylinder Capacity
58 L

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

HONEYWELL Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The HONEYWELL Calibration Gas: Nitrogen is a +/-10% accuracy, Cl2 calibration gas for portable gas detectors, supplied in a 58 L cylinder with a CGA 600 fitting. It contains a Chlorine 10 ppm mixture in a Nitrogen background, designed for use with gas detection instruments (MPN 600-0056-000).

Frequently Asked Questions

What is HONEYWELL calibration gas 600-0056-000 used for?

This HONEYWELL calibration gas is used to verify and calibrate portable gas detectors that sense chlorine. The 10 ppm Cl2 mixture in a nitrogen background, with +/-10% accuracy, ensures your gas detection instruments provide reliable readings in industrial safety applications.

What are the specifications of HONEYWELL calibration gas 600-0056-000?

This HONEYWELL calibration gas contains Chlorine 10 ppm in a Nitrogen background, with +/-10% accuracy. It is supplied in a 58 L cylinder with a CGA 600 fitting, designed for use with gas detection instruments. The manufacturer part number is 600-0056-000.

Where to buy HONEYWELL calibration gas 600-0056-000 worldwide?

3G Electric supplies and delivers the HONEYWELL calibration gas 600-0056-000 worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance to ensure this chlorine calibration gas reaches your facility, wherever you are located.

How to use HONEYWELL calibration gas 600-0056-000 for gas detector calibration?

Connect the cylinder's CGA 600 fitting to your gas detection instrument's regulator. Follow the manufacturer's instructions to apply the 10 ppm chlorine mixture at the recommended flow rate. Allow the reading to stabilize before adjusting the instrument to match the certified gas concentration.

Used in

Common applications for HONEYWELL
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits
Not sure this is the right part? Photo-identify it→

HONEYWELL Products

3G Electric supplies HONEYWELL calibration gases for portable gas detectors. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

Cross-referenced by specification & description
HONEYWELL
HONEYWELL
Calibration gas mixture of 5 ppm chlorine in nitrogen background, supplied in a 58 L cylinder with CGA C10 fitting. Used to verify and adjust the accuracy of portable gas detectors that sense chlorine
HONEYWELL
HONEYWELL
Calibration gas mixture containing 500 ppm hydrogen in air, supplied in a 103 L cylinder with CGA 600 connection. Used to verify and adjust the accuracy of portable gas detectors during routine safety checks
HONEYWELL
HONEYWELL
Calibration gas for portable gas detectors, supplied as a 34 L cylinder of 100% Nitrogen with a CGA C10 connection. Used to verify and adjust the accuracy of gas detection instruments in industrial environments
HONEYWELL
HONEYWELL
Calibration gas mixture of 10 ppm hydrogen cyanide in nitrogen, with ±10% accuracy. Supplied in a 58 L cylinder with CGA C10 fitting. Used for functional testing and calibration of portable gas detectors that sense hydrogen cyanide, typically with bump test stations
HONEYWELL
HONEYWELL
Calibration gas mixture containing 19% oxygen in a 58 L cylinder with CGA 600 connection. Used for verifying and adjusting the accuracy of portable gas detectors, particularly GasAlert Series Model Methane Sensors in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture of 50 ppm ammonia in nitrogen, supplied in a 58 L cylinder with a CGA C10 fitting. Used to verify and calibrate portable gas detectors that sense ammonia in industrial safety applications

More from HONEYWELL

View all HONEYWELL parts →
HONEYWELL
HONEYWELL
Calibration gas containing 99.9% nitrogen in a 103 L cylinder with CGA 600 connection. Used for verifying and adjusting the accuracy of portable gas detectors with nitrogen sensors in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture of 25 ppm nitric oxide in a nitrogen background, supplied in a 58 L cylinder with a CGA C10 connection. Used for verifying the accuracy of portable gas detectors that measure nitric oxide in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture of 10 ppm hydrogen sulfide in nitrogen, supplied in a 58-liter cylinder with a CGA C10 connection. Used to verify and adjust the response of portable gas detectors that sense hydrogen sulfide in industrial safety applications
HONEYWELL
HONEYWELL
Aerosol calibration gas containing 100 ppm carbon monoxide in an 11 L cylinder. Designed for verifying and calibrating GasAlert Series Model Carbon Monoxide sensors in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture of 2 ppm chlorine in nitrogen, supplied in a 58 L cylinder with CGA C10 connection. Used to verify and adjust the accuracy of portable gas detectors that sense chlorine in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas for portable gas detectors, containing 10 ppm hydrogen chloride in a nitrogen background. Supplied in a 58 L cylinder with a CGA C10 connection. Used to verify and adjust the response of gas detection instruments that measure hydrogen chloride
HONEYWELL
HONEYWELL
This calibration gas cylinder contains 50 ppm ammonia in nitrogen with +/-5% accuracy and a CGA C10 fitting. The 58 L capacity is used for verifying and calibrating portable gas detection instruments in industrial safety applications
HONEYWELL
HONEYWELL
Calibration gas mixture for portable gas detectors, containing Methane (2.5% LEL) and Oxygen 18% in a 58 L cylinder with CGA 600 connection. Used to verify and calibrate sensor response in industrial safety applications

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first