We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR GPL - Burners & Combustion
FBRBurners & Combustion

FBR GPL

FBR GAS XP 80/2 CE-LX4 is a two-stage gas burner designed for industrial heating applications with low NOx emissions (< 60 mg/kW). Operating across 170–850 kW thermal output with a 250 mm nozzle, it delivers…

SKU 3G-FBR-00423

Also listed as: 00242241 · 002422 41 · 002422-41

Brand
FBR
Item
GPL
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
43 kg
stage
2 stages
fuel type
Gas low nox
nozzle mm
250
fan motor w
1.5
power kw max
850
power kw min
170
ip protection
IP 40
noisiness dba
79-82
gas consumption
17/40.8-85.3
electrical supply
3
power supply info
3~400V, 1/N~230V-50Hz
current absorption a
3.1
thermal power mcal h
146/350-731
nominal electric power w
1.7
max combustion air temp c
60

Datasheet Content

GAS XP80/2 CE GAS BURNERS TWO STAGES 071098_A_gb GAS BURNERS TWO STAGES GAS XP80/2 CE Gas burners two stages with: aluminum body, fan at high pressurisation and combution head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. The burner is mounted on supports and tierods for burner extraction this permits retreat to disassemble and check the flame tube and the combustion head. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled and tested; complete of two stages working valve with flow adjustment, safety valve, minimum gas pressure switch and stabiliser filter of gas pressure. Complete off lange and gasket for installation on generator. Fig. 1 GAS XP80/2 CE GAS XP80/2 CE GAS XP80/2 CE GAS BURNERS TWO STAGES 071098_A_gb TECHNICAL DATA AND OPERATING RANGE DIAGRAM XP80/2 CE MODEL GAS XP80/2 CE Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 146/350-731 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 170/407-850 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 17/40.8-85.3 Gas flow G25 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 19.8/47.5-99.1 Gas flow G25.3 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 19.4/46.4-97 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 6.6/15.8-33 Fuel: NATURAL GAS (second family, G20, G25, G25.3) - L.P.G. (third family, G31) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Minimum pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] 94/53 Minimum pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] 24/24 Minimum pressure gas train D2"-S NATURAL GAS/L.P.G. ** [mbar] 21/23 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 Nominal electric power [kW] 1.7 Fan motor [kW] 1.5 Nominal motor current absorption [A] 3.1 Nominal auxiliary absorption [A] 0.7 Power supply: 3~400V, 1/N~230V-50Hz Electric protection degree: IP 40 NOx Class, NATURAL GAS (second family) 1 NOx Class, L.P.G. (third family) 2 Noisiness *** min. - max. [dB(A)] 79-82 Burner weight **** [kg] 43 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - Control method class 3 - The measured sound pressure tolerance can be assumed to be ± 1 [dB (A)]). **** For burner with long head add 2 kg to the weight. GAS XP80/2 CE GAS XP80/2 CE GAS BURNERS TWO STAGES 071098_A_gb [mbar] 14 GAS XP80/2 CE 12 10 8 6 4 2 0 0 100 200 300 400 500 600 700 800 900 [kW] The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. DIMENSIONS [MM] Fig. 3 Dimensions GAS TRAIN A B D1"1/4-S 437 382* D1"1/2-S 458 396 D2"-S 458 396 * Includes length of 66 mm due to adapter code 057020 ** Overall dimension with the burner out in position of maintenance. TC - TL: Please see chapter "Flame tube length" GASXP80/2CE GAS XP80/2 CE GAS BURNERS TWO STAGES 071098_A_gb BOILER PLATE The dimensions of the boiler plate must be as indicated in the drawing. * Suggested dimension of connection between burner and generator. MODEL L min L* L max M N min N max GAS XP80/2 CE mm 185 185 250 M12 310 365 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. FLAME TUBE LENGTH TC mm 250 TL mm 385 ** ** For different flame lengths, please contact our Technical-Sales Department. GAS XP80/2 CE GAS XP80/2 CE GAS BURNERS TWO STAGES 071098_A_gb BURNER SIGNAL DESCRIPTION In the picture below there are indicated all the signalation present on the burner: 1 2 LEGEND 1) ON/OFF button 2) Reset from lockout button + status lamp The multicolor signal lamp in the lockout reset button (pos.2) is the key indicating element for visual diagnostics and interface diagnostics. In normal operation, the different operating states are indicated in the form of color codes; please refer to electrical device handbook supplied with the present instructions. After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. By pressing the lockout reset button (pos.2) for more than 3 seconds, the visual diagnostics of the cause of fault can be activated; please refer to electrical device handbook supplied with the present instructions. For close the diagnostics mode and for switch on the burner again, it is necessary to reset the burner control. Press the lockout reset button (pos.2) for about 1 second (<3 seconds). After a non-alterable lockout, the red signal lamp in the lockout reset button (pos.2) lights up. For reset the control box press the lockout reset button (pos.2) for about 1 second (<3 seconds). GAS XP80/2 CE GAS XP80/2 CE GAS BURNERS TWO STAGES 071098_A_gb PRODUCT SPECIFICATION SHORT DESCRIPTION Gas burners two stages. DETAILED SPECIFICATION Gas burner two stages composed by: • Aluminum body; • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and inox steel flame disc; • Flange and insulating gasket for fixing at boiler; • Three-phase power supply; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Gas train with safety valve class A, adjustment two stages valve class A; • Optional valve proving system; • Ionisation probe for flame detection; • IP 40 electric protection level; • Servomotor for air shutter and for the consent of the 2nd stage gas valve; • Moving shutter with total closure when idle in order to reduce at the least energy losses related to boiler cooling down; • Supports and tierods for burner extraction. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive M.D.; • GAS 2016/426/UE Regulation; • Reference rules: EN676 (gas) – EN 746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Isomart gasket; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise protection; •…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS XP 80/2 CE-LX4 is a two-stage gas burner designed for industrial heating applications with low NOx emissions (< 60 mg/kW). Operating across 170–850 kW thermal output with a 250 mm nozzle, it delivers efficient combustion for medium to large-scale installations requiring emissions control.

Frequently Asked Questions

Where can I buy the FBR GAS XP 80/2 CE-LX4 gas burner worldwide?

3G Electric is an authorized distributor. We source and deliver the FBR GAS XP 80/2 CE-LX4 globally, handling logistics, customs, and documentation. Lead time on request.

What is the thermal output range of the FBR GAS XP 80/2 CE-LX4?

The burner operates across 170–850 kW thermal output with two-stage modulation for efficient combustion control in medium to large-scale heating installations.

What are the NOx emissions for this FBR gas burner?

The FBR GAS XP 80/2 CE-LX4 delivers low NOx emissions below 60 mg/kWh, meeting Class 4 emissions standards for regulated industrial heating applications.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS XP 80/2 CE-LX4 TL Cl. 4 | Variant: GPL | Subgroup: Burner
FBR
GAS XP 80/2 CE-LX4 TL Cl. 4 | Variant: GPL | Subgroup: Burner
GAS XP 80/2 CE-LX4 TC Cl. 4 | Variant: variant_1 | Subgroup: Burner
FBR
GAS XP 80/2 CE-LX4 TC Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS XP 80/M CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 80/M CE-LX4 TC Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 80/2 CE-LX4 TL Cl. 4 | Variant: variant_1 | Subgroup: Burner
FBR
GAS XP 80/2 CE-LX4 TL Cl. 4 | Variant: variant_1 | Subgroup: Burner
GAS XP 80/M CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
FBR
GAS XP 80/M CE-LX4 TL Cl. 4 | Variant: variant_2 | Subgroup: Burner
GAS XP 80/M CE-LX4 TC Cl. 4 | Variant: metano | Subgroup: Burner
FBR
GAS XP 80/M CE-LX4 TC Cl. 4 | Variant: metano | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL