We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR GPL - Burners & Combustion
FBRBurners & Combustion

FBR GPL

The FBR GPL is a two-stage gas burner complete with gas train, delivering a thermal power range of 10–29.5 kcal/h (min–max) and 11.6–34.3 kW. It operates on a 1/N~230V-50Hz electrical supply with a 0.55 A current…

SKU 3G-FBR-00553

Brand
FBR
Item
GPL
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
9 kg
stage
2 stages
fuel type
Gas
nozzle mm
90
fan motor w
50
power kw max
34.3
power kw min
11.6
ip protection
IP40
noisiness dba
57-58
power kcal max
29.5
power kcal min
10
gas consumption
1.8/2.3-5.8
electrical supply
1
power supply info
1/N~230V-50Hz
current absorption a
0.55
thermal power mcal h
15.5/20-50
nominal electric power w
80
max combustion air temp c
60

Datasheet Content

GAS BURNERS ONE STAGE SK_071054_E_en GAS X0-X1-X2-X3-X4-X5CE Gas burners one stage with: die-cast aluminum body, fan at high pressurisation, combustion head with adjustment at high efficiency and high flame stability and protection cover with noise reduction plate. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or G.P.L. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled, electrically linked and tested; complete of working valve with flow adjustment, safety valve, minimum gas pressure switch and stabiliser filter of gas pressure. Versions F with cover of protection in steel and specific features for the application on industrial ovens and bakery ovens. Complete of connector plug / socket 7 poles, flange and gasket for installation on generator. Fig. 1 GAS X0CE Fig. 2 GAS X2CE Fig. 3 GAS X3CE Fig. 4 GAS X4CE Fig. 5 GAS X5CE GAS X0-X1-X2-X3-X4-X5CE GAS BURNERS ONE STAGE SK_071054_E_en TECHNICAL DATA AND OPERATING RANGE DIAGRAM MODEL GAS X0CE GAS X1CE GAS X2CE GAS X3CE GAS X4CE GAS X5CE Thermal power min. - max. * [Mcal/h] 10-29.5 20-50 35-80 60-150 100-200 130-300 Thermal power min. - max. * [kW] 11.6-34.3 23.2-58.1 40.7-93 69.8-174 116-232 151-349 Gas flow G20 (NATURAL GAS) min. - max. * [Nm³/h] 1.2-3.4 2.3-5.8 4.1-9.4 7-17.5 11.7-23.4 15.2-35.1 Gas flow G31 (L.P.G.) min. - max. * [Nm³/h] 0.5-1.3 0.9-2.2 1.6-3.6 2.7-6.8 4.5-9 5.8-13.5 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL,I2E(R) / I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) one stage Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 60 60 60 60 60 Min. pressure gas train D1/2"-S NATURAL GAS/L.P.G. ** [mbar] 7/18 14/31 - - - - Min. pressure gas train D3/4"-S NATURAL GAS/L.P.G. ** [mbar] - - 18/24 - - - Min. pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] - - - 14/31 14/21 27/33 Min. pressure gas train D1"1/4-S NATURAL GAS/L.P.G. [mbar] - - - - - 16/25 ** Max. pressure at the entry of valves (Pe. max) [mbar] 60 60 360 360 360 360 Nominal electric power [W] 80 110 130 200 226 540 Fan motor [W] 50 75 75 110 200 370 Nominal motor current absorption [A] 0.5 0.6 0.6 0.9 1.1 2.4 Power supply: 1/N~230V-50Hz Electric protection degree: IP 40 IP 40 IP 40 IP 40 IP 40 IP 40 Noisiness *** min. - max. [dB(A)] 52-55 59-60 60-61 64-66 64-66 67-71 Burner weight **** [kg] 8 10 10 13 15 24 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). **** For burners: GAS X0CE - GAS X1CE - GAS X2CE - GAS X3CE - GAS X4CE with cover in steel (F) add 3 kg to the weight. **** For burner GAS X5CE with cover in steel (F) add 5 kg to the weight. [mbar] [kW] [Mcal/h] Fig. 6 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN676 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS X0-X1-X2-X3-X4-X5CE GAS BURNERS ONE STAGE SK_071054_E_en DIMENSIONS [mm] Fig. 7 Dimensions GAS X0CE - GAS X1CE - GAS X2CE - GAS X3CE - GAS X4CE MODEL A B C D E F G H P S TC TL * R1 R2 R3 R4 RD Gas train weight GAS X0CE D1/2"-S 15 140 140 90 43 265 169 72 150 150 90 150 132 200 254 240 Rp 1/2 2 kg GAS X1CE D1/2"-S 15 162 175 90 43 305 210 65 150 150 90 150 132 200 254 240 Rp 1/2 2 kg GAS X2CE D3/4"-S 15 162 175 90 43 305 210 65 150 150 90 150 138 220 262 328 Rp 3/4 3 kg GAS X3CE D1"-S 16 185 195 108 54 340 248 70 200 160 130 250 168 280 337 361 Rp 1 8 kg GAS X4CE D1"-S 20 185 195 125 78 368 248 70 200 200 160 280 173 280 337 385 Rp 1 8 kg Fig. 8 Dimensions GAS X5CE MODEL A B C D E F G H P S TC TL * R1 R2 R3 R4 RD Gas train weight GAS X5CE D1"-S 18 207 213 138 98 462 310 90 200 200 250 335 160 305 362 403 Rp 1 8 kg GAS X5CE CT-D1"-S 18 207 213 138 98 462 310 90 200 200 250 335 160 305 480 403 Rp 1 9 kg GAS X5CE D1"1/4-S 18 207 213 138 98 462 310 90 200 200 250 335 160 305 362 450 Rp 1 1/4 8 kg GAS X5CE CT-D1"1/4-S 18 207 213 138 98 462 310 90 200 200 250 335 160 305 480 450 Rp 1 1/4 9 kg * For different flame lengths, please contact our Technical-Sales Department. BOILER PLATE ** Suggested dimension of connection between burner and generator. Fig. 9 Boiler plate MODEL L min L** L max M N min N** N max GAS X0CE mm 130 150 170 M8 100 110 130 GAS X1CE mm 130 150 170 M8 100 110 130 GAS X2CE mm 130 150 170 M8 100 110 130 GAS X3CE mm 150 170 170 M8 120 130 140 GAS X4CE mm 170 205 226 M10 130 140 160 GAS X5CE mm 205 226 226 M10 150 150 180 GAS X0-X1-X2-X3-X4-X5CE GAS BURNERS ONE STAGE SK_071054_E_en PRODUCT SPECIFICATION SHORT DESCRIPTION Gas burners on stage. DETAILED SPECIFICATION Gas burner one stage composed by: • Die-cast aluminum body; • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and steel flame disc; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single-phase power supply; • Safety air pressure switch to stop the burner in case of failed or anomalous fan operation; • Gas train with safety valve and adjustment valve; • Ionisation probe for flame detection; • IP 40 electric protection level. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive M.D.; • GAS 2016/426/UE Regulation; • Reference rules: EN676 (gas) – EN 746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Isomart gasket; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Antivibration couplings; • Handle gas taps. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The FBR GPL is a two-stage gas burner complete with gas train, delivering a thermal power range of 10–29.5 kcal/h (min–max) and 11.6–34.3 kW. It operates on a 1/N~230V-50Hz electrical supply with a 0.55 A current absorption, 80 W nominal electric power, and a 50 W fan motor. The burner features a 90 mm nozzle, IP40 protection, noise level of 57–58 dBA, and a maximum combustion air temperature of 60 °C. 3G Electric interprets customer demand and delivers genuine industrial equipment across 14 departments—including combustion, pumps, and controls—with specialist depth as an authorised distributor for FBR and other leading OEMs.

Frequently Asked Questions

Where can I buy the FBR GPL gas burner with worldwide delivery?

3G Electric supplies the FBR GPL gas burner globally. We handle all logistics, customs clearance, and delivery to your facility. Lead time on request—contact us for availability and shipping terms.

What is the power output and firing range of the FBR GPL?

The FBR GPL delivers 11.6 kW minimum to 34.3 kW maximum thermal output. Two-stage modulation ensures efficient operation across partial and full-load conditions. Gas consumption ranges 1.8–5.8 m³/h depending on stage.

What are the electrical specifications for the FBR GPL burner?

Single-phase supply: 1N~230V 50Hz. Current absorption 0.55A. Fan motor rated 50W. IP40 protection and noise level 57–58 dB(A). Weight 9 kg. Compatible with standard 1/2" gas connections.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
X GAS X0 CE TC + RAMPA CE D1/2"-S | Variant: GPL | Subgroup: Burner complete with gas train
FBR
X GAS X0 CE TC + RAMPA CE D1/2"-S | Variant: GPL | Subgroup: Burner complete with gas train
X GAS X1 CE F + RAMPA CE D1/2"-S | Variant: GPL | Subgroup: Burner complete with gas train
FBR
X GAS X1 CE F + RAMPA CE D1/2"-S | Variant: GPL | Subgroup: Burner complete with gas train
FBR
FBR
X GAS XO CE TL + RAMPA CE D1/2"-S | Variant: metano | Subgroup: Burner complete with gas train
X GAS X1 CE F + RAMPA CE D1/2"-S | Variant: metano | Subgroup: Burner complete with gas train
FBR
X GAS X1 CE F + RAMPA CE D1/2"-S | Variant: metano | Subgroup: Burner complete with gas train
X GAS X0 CE TC + RAMPA CE D1/2"-S | Variant: metano | Subgroup: Burner complete with gas train
FBR
X GAS X0 CE TC + RAMPA CE D1/2"-S | Variant: metano | Subgroup: Burner complete with gas train
GAS CE D2"-S | Variant: GPL | Subgroup: Gas trains
FBR
GAS CE D2"-S | Variant: GPL | Subgroup: Gas trains

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL