We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR GPL - Burners & Combustion
FBRBurners & Combustion

FBR GPL

FBR GAS X3/M CE TC is a two-stage gas burner delivering 34.9–174 kW thermal power with progressive or modulating flame control. Operating at 66–71 dB with 110 W fan motor and 1N~230V 50Hz supply, it suits industrial…

SKU 3G-FBR-00502

Also listed as: 00270431 · 002704 31 · 002704-31

Brand
FBR
Item
GPL
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
18 kg
stage
2 stages sliding or modulating
fuel type
Gas
nozzle mm
130
fan motor w
110
power kw max
174
power kw min
34.9
ip protection
IP 40
noisiness dba
66-71
gas consumption
3.5/7-17.4
electrical supply
1
power supply info
1N~230V 50Hz
current absorption a
0.9
thermal power mcal h
30/60-150
nominal electric power w
200
max combustion air temp c
60

Datasheet Content

GAS BURNERS TWO STAGES PROGRESSIVE OR SK073030_B_en MODULATING GAS BURNERS TWO STAGES PROGRESSIVE OR MODULATING GAS X2/MCE - GAS X3/MCE - GAS X4/MCE Burners for gas two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. They are composed by: fan at high pressurisation, combustion head with adjustment at high efficiency and high flame stability and protection cover with noise reduction plate. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. Available in the versions METHANE (natural gas) or L.P.G. (to specify at the order) on demand specific versions for town gas, coal gas or biogas. Gas train completely assembled and tested; complete of one-block valve A class (1st stage slow opening + safety), minimum gas pressure switch and filter stabilizer. Complete of flange and gasket for installation on generator. Fig. 1 GAS X2/MCE Fig. 2 GAS X3/MCE Fig. 3 GAS X4/MCE GAS X2/MCE - GAS X3/MCE - GAS X4/MCE GAS BURNERS TWO STAGES PROGRESSIVE OR SK073030_B_en MODULATING TECHNICAL DATA GAS X2/MCE - GAS X3/MCE - GAS X4/MCE MODEL GAS X2/MCE GAS X3/MCE GAS X4/MCE Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [Mcal/h] 15/35-80 30/60-150 40/100-200 Thermal power min. 1°st. / min. 2°st. - max. 2°st. * [kW] 17/41-93 35/70-174 46/116-232 Gas flow G20 (NATURAL GAS) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 1.7/4.1-9.4 3.5/7-17.4 4.6/11.6-23.2 Gas flow G31 (L.P.G.) min. 1°st. / min. 2°st. - max. 2°st. * [Nm³/h] 0.7/1.6-3.6 1.3/2.7-6.5 1.8/4.5-9 Fuel: NATURAL GAS (second family) - L.P.G. (third family) Fuel category: I2R,I2H,I2L,I2E,I2E+,I2Er,I2ELL, I2E(R) I3B/P,I3+,I3P,I3B,I3R Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Environmental conditions operation / storage: -15...+40°C / -20...+70°C, umidità rel. max. 80% Max. temperature combustion air [°C] 60 60 60 Minimum pressure gas train D3/4"-S NATURAL GAS/L.P.G. ** [mbar] 18/24 -/- -/- Minimum pressure gas train D1"-S NATURAL GAS/L.P.G. ** [mbar] -/- 14/31 14/21 Minimum pressure gas train D1"1/4-S NATURAL GAS/L.P.G. ** [mbar] -/- 11/29.5 11/19 Minimum pressure gas train D1"1/2-S NATURAL GAS/L.P.G. ** [mbar] -/- 10/28 8/17 Maximum pressure at the entry of valves (Pe. max) [mbar] 360 360 360 Nominal electric power [W] 130 200 226 Fan motor [W] 75 110 200 Nominal current absorption [A] 0.6 0.9 1.1 Power supply: 1N~230V - 50Hz Electric protection degree: IP 40 IP 40 IP 40 Noisiness *** min. - max. [dBA] 61-62 66-71 66-71 Burner weight [kg] 13 18 20 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Minimal feeding-gas pressure to the gas train to get the maximum power of the burner, considering counter-pressure in combustion chamber of value 0 (zero). *** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law - method of control Class 3 - The tollerance of the measured pressure can be taken equal to ± 1 [dB(A)]). OPERATING RANGE DIAGRAM Fig. 4 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. GAS X2/MCE - GAS X3/MCE - GAS X4/MCE GAS BURNERS TWO STAGES PROGRESSIVE OR SK073030_B_en MODULATING DIMENSIONS [MM] Fig. 5 Dimensions GAS X2/MCE - GAS X3/MCE - GAS X4/MCE MODEL A B C D E F G H Q S U V R1 R2 R3 R4 RD Gas train weight GAS X2/MCE - D3/4"-S 15 162 200 90 43 305 215 65 170 211 150 150 178 220 262 346 Rp 3/4 2 kg GAS X3/MCE - D1"-S 20 185 224 107 56 344 268 70 193 248 202 162 212 280 338 300 Rp 1 5,6 kg GAS X3/MCE - D1"1/4-S 20 185 224 107 56 344 268 70 193 248 202 162 212 280 338 300 Rp 1 1/4 5,6 kg GAS X3/MCE - D1"1/2-S 20 185 224 107 56 344 292 70 193 248 202 162 212 280 338 443 Rp 1 1/2 8 kg GAS X4/MCE - D1"-S 20 185 224 125 80 371 274 70 193 248 206 200 218 280 338 323 Rp 1 5,6 kg GAS X4/MCE - D1"1/4-S 20 185 224 125 80 371 274 70 193 248 206 200 218 280 338 323 Rp 1 1/4 5,6 kg GAS X4/MCE - D1"1/2-S 20 185 224 125 80 371 298 70 193 248 206 200 218 280 338 467 Rp 1 1/2 8 kg **TC-TL: see "flame tube length" BOILER PLATE * Suggested dimension of connection between burner and generator. Fig. 6 Boiler plate MODEL L min L* L max M N min N* N max GAS X2/MCE mm 100 110 130 M8 130 150 170 GAS X3/MCE mm 120 130 140 M8 150 170 170 GAS X4/MCE mm 130 140 160 M10 170 205 226 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL ** GAS X2/MCE mm 90 150 GAS X3/MCE mm 130 250 GAS X4/MCE mm 160 280 ** For different flame lengths, please contact our Technical-Sales Department. GAS X2/MCE - GAS X3/MCE - GAS X4/MCE GAS BURNERS TWO STAGES PROGRESSIVE OR SK073030_B_en MODULATING PRODUCT SPECIFICATION SHORT DESCRIPTION Burners for gas two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. DETAILED SPECIFICATION Burner for gas two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe; composed by: • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and steel flame disc; • Protection cover with noise reduction plate; • Flange and insulating gasket for fixing at boiler; • Single phase power supply; • Safety air pressure switch to stop the burner in lock-out in case of failed or anomalous fan operation; • Gas train completely assembled and tested; complete of one-block valve A class (1st stage slow opening + safety), minimum gas pressure switch and filter stabilizer; • Ionisation probe for flame detection; • IP 40 electric protection level; • Spherical gas valve servo-controlled; progressive start and free way passage with total opening; • Servomotor for air shutter and for the spherical gas valve; • Set up for the additional specific kit that transforms burner operation as modulating i.e. the modulating kit allows to supply any power between the minimun and the maximum value based on instantaneous loading request. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive M.D.; • GAS 2016/426/UE Regulation; • Reference rules: EN676 (gas) – EN 746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Isomart gasket; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Power…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS X3/M CE TC is a two-stage gas burner delivering 34.9–174 kW thermal power with progressive or modulating flame control. Operating at 66–71 dB with 110 W fan motor and 1N~230V 50Hz supply, it suits industrial heating applications requiring flexible load management.

Frequently Asked Questions

Where can I buy the FBR GAS X3/M CE TC gas burner with worldwide delivery?

3G Electric is an authorized distributor of FBR gas burners. We handle procurement, logistics, and customs for delivery worldwide. Request a quote on the GAS X3/M CE TC—lead time available on request.

What is the thermal power output of the FBR GAS X3/M CE TC?

The FBR GAS X3/M CE TC delivers a range of 34.9 kW minimum to 174 kW maximum thermal power, with two-stage sliding or full modulating control via optional PID kit and probe.

Is the FBR GAS X3/M CE TC suitable for modulating operation?

Yes. The burner is equipped for two-stage progressive (hi-low flame) or fully modulating (PID) operation with the addition of an optional modulation kit and probe for flexible load management.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS X3/M CE TL | Variant: GPL | Subgroup: Burner
FBR
GAS X3/M CE TL | Variant: GPL | Subgroup: Burner
GAS X2/M CE TC | Variant: GPL | Subgroup: Burner
FBR
GAS X2/M CE TC | Variant: GPL | Subgroup: Burner
X GAS X3 CE TC | Variant: variant_2 | Subgroup: Burner
FBR
X GAS X3 CE TC | Variant: variant_2 | Subgroup: Burner
GAS X4/M CE TC | Variant: GPL | Subgroup: Burner
FBR
GAS X4/M CE TC | Variant: GPL | Subgroup: Burner
X GAS X3 CE TL | Variant: variant_2 | Subgroup: Burner
FBR
X GAS X3 CE TL | Variant: variant_2 | Subgroup: Burner
GAS X2/M CE TL | Variant: GPL | Subgroup: Burner
FBR
GAS X2/M CE TL | Variant: GPL | Subgroup: Burner

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL