FBR GAS/M CE-CT D2" FS50 is a progressive and modulating gas burner for industrial heating applications. It delivers thermal power up to 6500 Mcal/h with a 22 W fan motor and 500 mbar gas pressure. Suited for…

SKU 3G-FBR-00595

Also listed as: 0537502 · 053750 2 · 053750-2

Brand
FBR
Item
variant_1
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
315 kg
stage
Progressive and modulating
fuel type
Gas
nozzle mm
495
fan motor w
22
gas pressure
500
power kw max
1915
ip protection
IP54/IP40
noisiness dba
88-92
gas consumption
117/351-760
electrical supply
3
power supply info
3~400V, 1N~230V - 50Hz
current absorption a
43
thermal power mcal h
1000/3000-6500
nominal electric power w
22.5
max combustion air temp c
60

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR GAS/M CE-CT D2" FS50 is a progressive and modulating gas burner for industrial heating applications. It delivers thermal power up to 6500 Mcal/h with a 22 W fan motor and 500 mbar gas pressure. Suited for mid-to-large capacity combustion systems requiring staged control.

Frequently Asked Questions

Where can I buy the FBR GAS/M CE-CT D2 FS50 gas burner worldwide?

Order the FBR GAS/M CE-CT D2 FS50 from 3G Electric. We are an authorised distributor handling worldwide delivery, customs clearance, and logistics for industrial gas burners and combustion equipment.

What is the lead time and delivery timeline for the FBR gas burner?

Lead times vary by region and stock status. Contact 3G Electric for a quote and confirmed lead time on the FBR GAS/M CE-CT D2 FS50. We manage international logistics and can arrange delivery to your facility.

What is the maximum thermal output and control capability of the FBR GAS/M CE-CT D2 FS50?

The FBR GAS/M CE-CT D2 FS50 delivers 1915 kW maximum power with progressive and modulating control. It operates at 500 mbar gas pressure with a 22 W fan motor, suited for mid-to-large industrial heating applications requiring staged combustion control.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS/M CE-CT D2" S | Variant: variant_2 | Subgroup: Gas trains
FBR
GAS/M CE-CT D2" S | Variant: variant_2 | Subgroup: Gas trains
GAS/M CE-CT D1"1/2-S | Variant: variant_2 | Subgroup: Gas trains
FBR
GAS/M CE-CT D1"1/2-S | Variant: variant_2 | Subgroup: Gas trains
GAS/2 CE-CT D1"1/2-S | Variant: variant_2 | Subgroup: Gas trains
FBR
GAS/2 CE-CT D1"1/2-S | Variant: variant_2 | Subgroup: Gas trains
GAS/2 CE-CT D2" S | Variant: variant_1 | Subgroup: Gas trains
FBR
GAS/2 CE-CT D2" S | Variant: variant_1 | Subgroup: Gas trains
GAS/M CE D2" FS50 | Variant: metano | Subgroup: Gas trains (1)
FBR
GAS/M CE D2" FS50 | Variant: metano | Subgroup: Gas trains (1)
GAS/M CE D2" -S-F50 | Variant: variant_1 | Subgroup: Gas trains (1)
FBR
GAS/M CE D2" -S-F50 | Variant: variant_1 | Subgroup: Gas trains (1)

More from FBR

View all FBR parts
FBR
FBR
GAS X1 CE TL
FBR
FBR
GAS P 130/M CE-LX4 EL EVO TL
GAS P 550/M CE-LX TL EL EVO
FBR
GAS P 550/M CE-LX TL EL EVO
FBR
FBR
GAS X 0 CE THLS
GAS XP 40/M CE TC
FBR
GAS XP 40/M CE TC
FBR
FBR
GAS P 190/M CE-LX TL MEC
FBR
FBR
GAS P 450/M CE-LX TL EL EVO
FBR
FBR
GAS X 3/2 CE-LX TL