We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR FNDP 70/2 TC SI - Burners & Combustion
FBRBurners & Combustion

FBR FNDP 70/2 TC SI

FBR FNDP 70/2 TC SI is a two-stage heavy oil burner delivering 35–70 kg/h fuel flow across a 399–798 kW thermal power range. The unit operates on 3-phase 400 V power with IP 40 protection, making it suitable for…

SKU 3G-FBR-00273

Brand
FBR
Item
FNDP 70/2 TC SI
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
Weight
41 kg
stage
2 stages
fuel type
Heavy oil
nozzle mm
250
fan motor w
1.5
power kw max
798
power kw min
399
flow kg h max
70
flow kg h min
35
ip protection
IP 40
noisiness dba
77-78
pump motor kw
0.55
electrical supply
3
power supply info
3~400V,
current absorption a
4.35
thermal power mcal h
343-686
nominal electric power w
14
max combustion air temp c
60

Datasheet Content

HEAVY-OIL BURNERS TWO STAGES SK072005_C_en FNDP 25/2 - FNDP 45/2 - FNDP 70/2 Burners for heavy-oil two stages. Composed by: die-cast aluminum body, fan at high pressurisation, combustion head with adjustment at high efficiency and high flame stability and hydraulic system of regulation combustive air on the two stages of flame. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for operations of setting and maintenance. Complete of nozzles holder with integrated valves group and additional antigas valve, multistage preheating tank with flanged heating elements, cylindrical metal mesh filter, preheating thermostat, antismoke thermostat, gasket for installation on generator, nozzles, flexible hoses, line filter with heating resistance controlled by thermostat. Fig. FNDP 70/2 FNDP 25/2 - FNDP 45/2 - FNDP 70/2 HEAVY-OIL BURNERS TWO STAGES SK072005_C_en TECHNICAL DATA FNDP 25/2 - FNDP 45/2 - FNDP 70/2 MODEL FNDP 25/2 FNDP 45/2 FNDP 70/2 Flow min. - max. * [kg/h] 12-25 20-45 35-70 Thermal power min. - max. * [Mcal/h] 118-245 196-441 343-686 Thermal power min. - max. * [kW] 137-284 227-512 398-796 Fuel: HEAVY-OIL MAX 20°E at 50°C Intermitted working operation (min. 1 stop every 24 hours) two stages Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Fan motor [kW] 0.73 1.1 1.5 Resistances [kW] 3 4 7.4 Power supply: 3~400V, 1N~230V - 50Hz Electric protection degree: IP 40 Noisiness ** min-max [dBA] / / 77-78 Burner weight [kg] 35 36 41 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level). ** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746). OPERATING RANGE DIAGRAM [mbar] 13 11 9 7 5 3 1 -1 0 100 200 300 400 500 600 700 800 900 1000 [kW] Fig. X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. FNDP 25/2 - FNDP 45/2 - FNDP 70/2 HEAVY-OIL BURNERS TWO STAGES SK072005_C_en DIMENSIONS [MM] I O F H D H G E A B TC-TL C1 - C2 * * Overall dimension with the burner out in position of maintenance. Fig. Dimensions FNDP 25/2 - FNDP 45/2 - FNDP 70/2 MODEL A B C1 C2 * D E F G H I H FNDP 25/2 282 320 640 1150 133 325 155 18 280 / / FNDP 45/2 282 320 640 1150 150 325 155 18 280 / / FNDP 70/2 285 325 655 1165 164 357 170 18 300 10 144 BOILER PLATE ** Suggested dimension of connection between burner and generator. Fig. Boiler plate MODEL L min L max M N** FNDP 25/2 mm 283 340 M12 145 FNDP 45/2 mm 283 340 M12 160 FNDP 70/2 mm 340 368 M12 180 FLAME TUBE LENGTH Flame tube length must be selected based on the specifications supplied by boiler manufacturer and, in any case, it must be greater than the thickness of the boiler door included its insulation. In case of boilers with flame inversion or front flue combustion chambers, it is necessary to insulate the area between the flame tube and front door with refractory material. This protection material must not impede flame tube extraction. MODEL TC TL *** *** For different flame lengths, please 170 350 contact our Technical-Sales Department. FNDP 25/2 mm FNDP 45/2 mm 170 350 FNDP 70/2 mm 250 350 FNDP 25/2 - FNDP 45/2 - FNDP 70/2 HEAVY-OIL BURNERS TWO STAGES SK072005_C_en PRODUCT SPECIFICATION SHORT DESCRIPTION Heavy-oil burners two stages. DETAILED SPECIFICATION Heavy-oil burner two stages composed by: • Die-cast aluminum body; • Fan at high pressurisation; • Combustion head with adjustment at high performance and elevated flame stability; • Flange and insulating gasket for fixing at boiler; • Three-phase with neutral power supply; • Photodiode for flame detection; • IP 40 electric protection level; • Supports and tierods for burner extraction; • Easy extraction of combustion head without get off the burners by bolier. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2006/42/CE - 2006/42/EG - 2006/42/EC Directive MAC; • 2014/68/EU (art.4, par.3) Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter electrically heated and equipped with a thermostat; • Isomart gasket; • Nozzles; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Noise protection. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. FNDP 25/2 - FNDP 45/2 - FNDP 70/2
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR FNDP 70/2 TC SI is a two-stage heavy oil burner delivering 35–70 kg/h fuel flow across a 399–798 kW thermal power range. The unit operates on 3-phase 400 V power with IP 40 protection, making it suitable for industrial heating and power generation applications.

Frequently Asked Questions

Where can I buy the FBR FNDP 70/2 TC SI heavy oil burner?

3G Electric is an authorized distributor of FBR burners worldwide. We source the FNDP 70/2 TC SI to order with full logistics and customs handling. Lead time on request — contact us for availability and delivery terms.

What is the thermal output range of the FBR FNDP 70/2 TC SI?

The FNDP 70/2 TC SI delivers 399–798 kW thermal power with a fuel flow of 35–70 kg/h across two modulating stages. It operates on 3-phase 400 V supply with 4.35 A current absorption.

Is the FBR FNDP 70/2 TC SI suitable for power generation applications?

Yes. The FNDP 70/2 TC SI is designed for industrial heating and power generation. It provides two-stage modulation for load matching, IP 40 protection, and 77–78 dBA noise output, meeting typical plant requirements.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FNDP 70/2 TL SI
FBR
FNDP 70/2 TL SI
FNDP 45/2 TC SI
FBR
FNDP 45/2 TC SI
FNDP 100/2 TC SI
FBR
FNDP 100/2 TC SI
FNDP 70/M TC SA
FBR
FNDP 70/M TC SA
FNDP 25/2 TC SI
FBR
FNDP 25/2 TC SI
FNDP 70/M TL SA
FBR
FNDP 70/M TL SA

More from FBR

View all FBR parts
FNDP 100/2 TC
FBR
FNDP 100/2 TC
FBR
FBR
FNDP 750/M TL MEC
FBR
FBR
FNDP 250/M TL MEC
FBR
FBR
FNDP 450/M TL MEC
FBR
FBR
FNDP 350/M TL MEC
FBR
FBR
FNDP 150/M TL
FNDP 125/2 TC
FBR
FNDP 125/2 TC
FBR
FBR
FNDP 190/M TL MEC