Datasheet Content
HEAVY-OIL BURNERS TWO STAGES SK072066_B_en
HEAVY-OILBURNERSTWOSTAGES
FNDP100/2-FNDP125/2-FNDP150/2
Burnersforheavy-oiltwostages.
Availableintwoversions:
-FNPforfluidheavyoilupto3,5°Eat50°C
-FNDPfordenseheavyoilupto20°Eat50°C
Theyarecomposedby:fanathighpressurisation,combustionheadwithadjustmentathighefficiencyandhighflame
stabilityandhydraulicsystemofregulationcombustiveaironthetwostagesofflame.
Compactoveralldimensionsanddispositionrationalizedofthecomponentswithaccessibilityfacilitatedforthe
operationsofsettingandmaintenance.
Completeofnozzles,flexiblepipesandlinefilter(forthemodelsFNDPthelinefilteriselectricallyheatedand
equippedwithathermostat).
Completeofflangeandgasketforinstallationongenerator.
FNDP100/2-FNDP125/2-FNDP150/2
HEAVY-OIL BURNERS TWO STAGES SK072066_B_en
TECHNICALDATAFNDP100/2-FNDP125/2-FNDP150/2
MODEL FNDP100/2 FNDP125/2 FNDP150/2
Flow min. - max. * [kg/h] 40-100 60-125 70-150
Thermal power min. - max. * [Mcal/h] 392-980 588-1225 687-1500
Thermal power min. - max. * [kW] 456-1139 684-1424 798-1744
Fuel: HEAVY-OIL MAX 20°E at 50°C
Intermitted working operation (min. 1 stop every 24 hours) two stages
Environmental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80%
Max. temperature combustion air [°C] 60
Fan motor [kW] 2.2 3 4
Resistances [kW] 9 11 12
Power supply: 3/N~400V,1N~230V-50Hz
Electric protection degree: IP40
Burner weight [kg] 100 130 136
*Referenceconditions:Environmenttemperature20°C-Barometricpressure1013mbars-Altitude0metre(sealevel).
OPERATINGRANGEDIAGRAM
[mbar] 13
11
9
7
5
3
1
FNDP 100/2 FNDP 125/2 FNDP 150/2
-1
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 [kW]
Fig. 1 X = Thermal power Y = Pression in the combustion chamber
The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler.
For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance,
contact the manufacturer.
FNDP100/2-FNDP125/2-FNDP150/2
HEAVY-OIL BURNERS TWO STAGES SK072066_B_en
DIMENSIONS [MM]
Fig. 2 DimensionsFNDP100/2-FNDP125/2-FNDP150/2
MODEL A A max. B C D ØE TC TL I ØL M N
FNDP100/2 656 1085 440 410 400 175 235 335 368 340 M12 190
FNDP125/2 820 1400 520 420 400 209 200 400 368 340 M14 230
FNDP150/2 820 1400 520 420 400 209 200 400 368 340 M14 230
FNDP100/2-FNDP125/2-FNDP150/2
HEAVY-OIL BURNERS TWO STAGES SK072066_B_en
PRODUCT SPECIFICATION
SHORT DESCRIPTION
Light-oil burners two stages available in two versions: FNP for fluid heavy oil up to 3,5°E at 50°C or FNDP for dense
heavy oil up tol 20°E at 50°C.
DETAILED SPECIFICATION
Light-oil burner two stages available in two versions: FNP for fluid heavy oil up to 3,5°E at 50°C or FNDP for dense
heavy oil up tol 20°E at 50°C composed by:
• Fanathighpressurisation;
• Combustionheadwithadjustmentathighperformanceandelevatedflamestability;
• Flangeandinsulatinggasketforfixingatboiler;
• Three-phasewithneutralpowersupply;
• Photodiodeforflamedetection;
• IP40electricprotectionlevel;
• Supportsandtierodsforburnerextraction;
• Easyextractionofcombustionheadwithoutgetofftheburnersbybolier.
CONFORMING TO:
• CE rules;
• 2014/30/UE Directive E.M.C.;
• 2014/35/UE Directive L.V.;
• 2006/42/CE - 2006/42/EG - 2006/42/EC Directive MAC;
• 2014/68/EU (art.4, par.3) Directive P.E.D.;
• Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment).
STANDARD EQUIPMENT
• Flexiblehosesforconnection;
• Linefilter (forthemodelsFNDPthelinefilteriselectricallyheatedandequippedwithathermostat);
• Isomartgasket;
• Nozzles;
• Flangewithinsulatinggasket;
• Burnernameplate;
• Warranty;
• Instructionhandbookforinstallation,useandmaintenance.
OPTIONAL
• Noiseprotection.
Theillustrationsanddatahereshownareindicative.F.B.R.BruciatoriS.r.l.reservestherighttobring,withoutanyobligationofwarning,anychangesthatwouldbeappropriatetothecontinuingdevelopmentoftheirproducts.
FNDP100/2-FNDP125/2-FNDP150/2