We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

FBR FGP 650/M TL EL - Burners & Combustion
FBRBurners & Combustion

FBR FGP 650/M TL EL

FBR FGP 650/M TL EL is a light-oil diesel burner delivering 986–7558 kW thermal power with progressive two-stage or modulating flame control. Operating at 3~400V, it achieves 84–88 dBA noise levels and suits…

SKU 3G-FBR-00762

Also listed as: FGP650MTLEL · FGP 650 M TL EL · FGP-650-M-TL-EL

Brand
FBR
Item
FGP 650/M TL EL
Category
Burners & Combustion
UNSPSC
40101834 — Burners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Authorized Distributor
Direct from OEM
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

FBR
stage
Progressive and modulating
fuel type
Light oil
nozzle mm
721
fan motor w
22
power kw max
7558
power kw min
986
flow kg h max
637
flow kg h min
85
ip protection
IP40
noisiness dba
84-88
pump motor kw
3
electrical supply
3
power supply info
3~400V 1/N~230V-50Hz
thermal power mcal h
968/3400-7500
nominal electric power w
27
max combustion air temp c
60

Datasheet Content

LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR SK070071_B_en MODULATING LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR MODULATING FGP 650/M Burners for light-oil two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. They are composed by: fan at high pressurisation and combustion head with adjustment at high efficiency and high flame stability. Compact overall dimensions and disposition rationalized of the components with accessibility facilitated for the operations of setting and maintenance. The adoption of strong metal components makes the burner durable also in heavy duty conditions. Complete of nozzle, flexible pipes and line filter. Complete of flange and gasket for installation on generator. Available with mechanical cam or with electronic cam. Fig. 1 Fig. 2 Fig. 3 Fig. 4 FGP 650/M LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR SK070071_B_en MODULATING TECHNICAL DATA MODEL FGP 650/M Thermal power min.1°st. / min.2°st. - max.2°st. * [Mcal/h] 847/3000-6500 Thermal power min.1°st. / min.2°st. - max.2°st. * [kW] 986/3488-7558 Light-oil flow min.1°st. / min.2°st. - max.2°st. * [kg/h] 85/294-637 Fuel: Light-oil 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1 Intermitted working operation (min. 1 stop every 24 hours) two stages progressive or modulating Enviromental conditions operation / storage: -15...+40°C / -20...+70°C, rel. humidity max. 80% Max. temperature combustion air [°C] 60 Nominal electric power [kW] 21 Fan motor [kW] 18.5 Pump motor [kW] 2.2 Fan motor absorption [A] 36.2 Pump motor absorption [A] 5.4 Nominal absorption burner auxiliary [A] 4 Power supply 3~400V - 1/N~230V-50Hz Degree of electric protection IP40 Noiseness ** max. [dB(A)] 85 Burner weight [kg] 540 * Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level) ** Measured sonorous pressure in the laboratory combustion, with functional burner on beta boiler to 1 metre of distance (UNI EN ISO 3746 law). OPERATING RANGE DIAGRAM [mbar] [kW] [Mcal/h] Fig. 5 X = Thermal power Y = Pression in the combustion chamber The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler. For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance, contact the manufacturer. FGP 650/M LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR SK070071_B_en MODULATING BURNER DIMENSIONS [MM] Fig. 6 Burner dimensions MODEL A B C D E F H TL FGP 650/M 600 654 845 439 833 1453 22 721 BOILER PLATE The dimensions of the boiler plate (threaded holes or studs) must be as indicated in the drawing. Fig. 7 Boiler plate MODEL M N min N* N Max L min L max FGP 650/M mm M16 707 778 778 460 540 * Suggested dimension. FGP 650/M LIGHT-OIL BURNERS TWO STAGES PROGRESSIVE OR SK070071_B_en MODULATING PRODUCT SPECIFICATION SHORT DESCRIPTION Light-oil burners two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe. DETAILED SPECIFICATION Light-oil burner two stages progressive (hi-low flame) or modulating (PID fully modulating) if equipped with addition of optional modulation kit and probe; composed by: • Frame made of steel; • Centrifugal fan at high pressurization with reverse curved blades at low noisiness; • Combustion head with adjustment at high performance and elevated flame stability equipped with inox steel blast tube and steel flame disc; • Easy extraction of combustion head without get off the burners by bolier; • Flange and insulating gasket for fixing at boiler/furnace; • Control box for control and supervision of burner; • Photoresistance for flame detection; • Three-phase power supply; • Fan motor start-up made by delta/star system; • IP40 electric protection level; • Safety air pressure switch to stop the fuel pump in case of failed or anomalous fan operation, causing the lockout of the burner; • Servomotor for air shutter and for the fuel pressure regulator; • Mobile shutter with total closure when idle for minimize the energetic losses related at boiler cooling; • Light-oil gear pump operated by specific electric motor; • Nozzle assembly with magnet to control inlet/return needle nozzle; • Maximum light-oil pressure switch to stop the burner in case of the light-oil pressure on the return is higher then the set point value; • Set up for the additional specific kit that transforms burner operation as modulating i.e.the modulating kit allows to supply any power between the minimum and maximum value based on instantaneous loading request. CONFORMING TO: • CE rules; • 2014/30/UE Directive E.M.C.; • 2014/35/UE Directive L.V.; • 2014/68/EU Directive M.D.; • 97/23/CE Directive P.E.D.; • Reference rules: EN267 (liquid fuel) - EN746-2 (industrial thermoprocessing equipment). STANDARD EQUIPMENT • Flexible hoses for connection; • Line filter; • Isomart gasket; • Nozzle; • Flange with insulating gasket; • Burner nameplate; • Warranty; • Instruction handbook for installation, use and maintenance. OPTIONAL • Power modulating kits for temperatures; • Power modulating kits for pressures; • Temperature probe 0°C-400°C (PT 100 a 0° C); • Temperature probe 0°C-1200°C (K probe); • Pressure probe 0-3 bar, 0-6 bar. 0-16 bar, 0-20 bar, 0-30 bar; • Noise protection. The illustrations and data here shown are indicative. F.B.R. Bruciatori S.r.l. reserves the right to bring, without any obligation of warning, any changes that would be appropriate to the continuing development of their products. FGP 650/M
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

FBR Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

FBR FGP 650/M TL EL is a light-oil diesel burner delivering 986–7558 kW thermal power with progressive two-stage or modulating flame control. Operating at 3~400V, it achieves 84–88 dBA noise levels and suits industrial heating and process applications requiring flexible combustion turndown.

Frequently Asked Questions

Where can I source the FBR FGP 650/M TL EL diesel burner in your region?

3G Electric supplies the FBR FGP 650/M TL EL burner with delivery to your location. We handle all customs import customs, USD invoicing, and logistics to your facility. Lead time on request.

What is the lead time and delivery process to your region?

Lead time varies by stock availability at origin. 3G Electric manages customs clearance, shipping coordination, and final delivery to your location, your location, and other your regionn locations. Contact us for a specific delivery estimate and freight costs.

What thermal power range and control options does the FGP 650/M TL EL offer?

The FBR FGP 650/M TL EL delivers 986 kW minimum to 7558 kW maximum thermal output. It features progressive two-stage hi-low flame control or optional fully modulating PID control with probe. Noise level is 84–88 dBA at 3~400V operation.

Used in

Common applications for FBR
Hospitality and commercial HVAC — cast-iron boiler plants in hotels and shopping complexes
Pharmaceutical and biotech process heat — gas-fired burners with ATEX gas trains for classified-zone requirements
Medical-waste and bio-hazard incineration — FGP progressive dual-fuel systems
Food and beverage steam boilers — single-stage G-series for continuous-duty cycles
Marine and offshore platforms — IP54-rated X-series for high-humidity marine operations

FBR Products

3G Electric supplies FBR burners & combustion. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
FGP 750/M TL EL
FBR
FGP 750/M TL EL
FGP 1800/M TL EL
FBR
FGP 1800/M TL EL
FGP 1500/M TL EL
FBR
FGP 1500/M TL EL
FGP 1000/M TL EL
FBR
FGP 1000/M TL EL
HI-FGP 650/M TL
FBR
HI-FGP 650/M TL
FGP 1300/M TL EL
FBR
FGP 1300/M TL EL

More from FBR

View all FBR parts
FBR
FBR
K 350/M TL
FBR
FBR
G 0S LX TC
FBR
FBR
G X5 F TL
FBR
FBR
G X4.22 LX TL
FBR
FBR
K X6/M EL EVO TL
FGP 1500/M TL MEC
FBR
FGP 1500/M TL MEC
FGP 75/2 LX TC
FBR
FGP 75/2 LX TC
FBR
FBR
K 250/M TL EL