CBM Transformer type T8 CM150 (replaces 15000001)

CBM Type T8 CM150 is an ignition transformer for industrial combustion systems, delivering dual 6.5 kV outputs at 460 VA with polyester resin isolation. Its compact two-pole design and 700 mm supply cable suit…

SKU 3G-CBM-06958

Also listed as: TRF 05108 · TRF-05108

Brand
CBM
Item
Transformer type T8 CM150
Category
Ignition & Transformers
UNSPSC
39121003 — Instrument transformers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

CBM
type
T8 CM150
isolation
polyester resin
number of poles
2
output voltage kv
2 x 6.5
power consumption va
460
supply cable length mm
700

Datasheet Content

IGNITION DESCRIPTION The ignition transformers type T8… - T16/D - T18… - T20 TRANSFORMERS have the same overall dimensions, but different electric features and fixing systems. TYPES T8.. T16/D T18.. T20.. These transformers are used in different applications depending on their electric features, i.e.: − The T8/… transformers are suitable for high thermal power burners or pressurised burners for light or heavy oil. − The T16/D transformers are suitable for fluid or gaseous fuel burners. − The T18/... transformers, which are designed for permanent operation, are suitable for the application on industrial machines (e.g. water cleaners). − The T20/... transformers are suitable to equip light or heavy oil burners designed for frequent and repeated starts (e.g. burners for steam boilers, cooking furnaces, and so on). FEATURES Followings are the main features of this series: - various connection and fixing systems; - high discharge power; - high efficiency and ignition powe r. TECHNICAL DATA - Supply voltage: 220V - 50Hz (different voltage and frequency values are available on request) - Operating temperature range: -10°C +60°C - Isolation: polyester resin - Recommended distance between the electrodes: 3÷5mm - Supply cable standard length: 700 mm T8/... T16/D T18/... T20/... Number of poles 2 2 2 2 Output peak 2 x 6.5 2x5 2 x 4.5 2x5 voltage (KV) Output effective 35 20 16 23 current (mA) (1) Input effective 2.1 1,1 0.77 1.3 current (A) Duty cycle 33% in 3 33% in 3 100% 66% in 3 minutes minutes minutes Power 460 240 170 285 consumption (VA) Weight (Kg) 3.5 30 3.7 3.2 (1) : short circuit secondary. CONSTRUCTION This series consists of column -type transformers, i.e. ignition transformers fitted with 2 primary windings and 2 secondary windings, except for type T16/D which is a shell -type transformer. All types are isolated by a special high isolation separator. High voltage isolation is achieved by means of a special kind of vacuum cast polyester resin. The housing is made of stove enamelled pressed metal. Each transformer is specified by the letter T (transformer), by one or more figures indicating the model and sometimes by some letters referring to the parti cular fixing system, i.e.: 3965_r00 1/2 TXX/X    → fixing system → model If the fixing system used is standard, the corresponding reference letter is not inserted in the part reference. For instance, the part reference T8 refers to a transformer with standard fixing system, whereas the part reference T8/B corresponds to a T8 transformer with different fixing system (see Fig.1, type B). The transformers of this series can have the same electric Fig.2 features but different fixing system s, or vice versa. OVERALL DIMENSIONS INSTALLATION Fig.1 shows the main overall dimensions and the various − Connect and disconnect the ignition transformer only after fixing systems of these transformers. switching off the power supply. − Respect the applicable national and European standards CONNECTION (e.g. EN 60355-1 / EN 50165) regarding electrical safety. The high voltage isolators employed in this series of − Make sure that the earth of the transformer and the earth transformers are of two different types (see Fig.2), accor ding of the electric system are well connected. as the connection with high voltage cables occurs by means − The device can be mounted in any position. of a screw or of a 6.3 diameter cylindrical terminal type Rajah. − Do not put high voltage cables next to other cables. If not expressly mentioned, the connection terminal used is a − Guarantee a protection degree suitable to the applica tion. screw terminal. Both isolators are made of ceramic. Fig.1 BRAHMA S.p.A. Via del Pontiere, 31 37045 Legnago (VR) Tel. +39 0442 635211 - Telefax +39 0442 25683 03/03/17 Subj ect to amendments without notice http://www.brahma.it E-mail : [email protected] 2/2 3965_r00

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CBM Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

CBM Type T8 CM150 is an ignition transformer for industrial combustion systems, delivering dual 6.5 kV outputs at 460 VA with polyester resin isolation. Its compact two-pole design and 700 mm supply cable suit retrofit and OEM integration applications.

Frequently Asked Questions

Where can I buy the CBM T8 CM150 ignition transformer in your region?

3G Electric sources the CBM T8 CM150 ignition transformer and arranges delivery to your location, your location, and nationwide locations. We handle all customs documentation and logistics. Contact us for availability and lead time on this model.

What is the lead time and delivery process for the CBM T8 CM150?

Lead time is on request depending on current stock and origin warehouse status. 3G Electric coordinates all import documentation, customs clearance, and final delivery to your site in your region. We invoice in USD and manage full logistics support.

What are the output specifications of the CBM T8 CM150 ignition transformer?

The CBM T8 CM150 delivers dual 6.5 kV outputs at 460 VA total power consumption. It features polyester resin isolation, a compact two-pole design, and includes a 700 mm supply cable for straightforward retrofit and OEM integration into industrial combustion equipment.

Used in

Common applications for CBM
Industrial boilers — CBM circulation pumps (mod. CM 30W) and solenoid valves (ELV series) for heating-loop control and pump staging.
Burner systems — CBM oil nozzles (FLU atomizer types), electrodes (ELC 200 mm), and solenoid coils (ELV 230V AC) for combustion ignition and flame supervision.
Plant maintenance and retrofit — CBM cable glands (CLI M25), motor couplings (ACC type D), and small-radius fittings (RAC 90°) for equipment reconfiguration and sensor integration.
Boiler water treatment — CBM chlorine test kits (DET free+combined) for feedwater and circulating-water quality monitoring in closed-loop systems.
Pump and motor assembly — CBM couplings, fittings, and cable glands for assembly and rewinding of industrial motors, circulation pumps, and auxiliary equipment.

CBM Products

3G Electric supplies CBM ignition & transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
COFI
COFI
Type T18 transformer
COFI
COFI
T16M type transformer
COFI
COFI
Transformer type T17M
COFI
COFI
Transformer type T14/T
Danfoss
Danfoss
Transformer type ZT930
Danfoss
Danfoss
Transformer type ZT931

More from CBM

View all CBM parts
Brahma T11/M Ignition Transformer
CBM
Brahma T11/M Ignition Transformer