NE
SIT Group
W
577 DBC
ELECTRONIC BURNER CONTROL DEVICE
WITH MICROPROCESSOR FOR INTEGRAL
MOUNTING ON SIT SIGMA
MULTIFUNCTIONAL CONTROLS
Field of application Main features
Home gas appliances such Gas burner ignition and
Subject to change without notice
as boilers (with natural or control functions integrated
forced draught including and managed by digital
dynamic control of the air technology (microprocessor).
pressure switch), water
heaters,hot air generators
Reference standards
and gas radiators.
EN 298 with reference to
9.955.841 117
the “Gas Appliance
Directive“ (GAD 90/396/EEC).
w w w . s i t g r o u p . i t
577 DBC
DESCRIPTION AND APPLICATION
The 577 Digital Burner Control is a family of electronic devices with integrated functions
for the safety and the control of combustion in home gas appliances and has the same
functions of 537 ABC family, with which it is interchangeable.
The 577 DBC is dedicated in particular to boilers, water heaters and hot air generators
with both natural draught and fan assisted burners.
All the functions are managed by a microprocessor and the product has obtained the
certification of conformity with the most severe safety requirements.
The microprocessor structure combines the traditional features of reliability with high
flexibility for the needs of the appliance and a wide range of possibilities for further
customisation with adds-on such as timers, multiple attempts and so on.
The 577 DBC family of products has been specifically designed for fixing on SIT 840,
845 and 848 SIGMA multifunctional controls by means of an exclusive plastic box
which integrates itself with the valve body and simplifies the connection of the solenoid
valves.
Further customisation is easy to achieve thanks to the digital technology.
All the hardware and software architecture has been designed by SIT and innovative
concepts and technologically advanced solutions have been implemented so as to
enhance the device’s reliability and performances.
BASIC FEATURES
- Compact design
- Direct assembly on the gas control
- Incorporated igniter with EMC filter
- Direct burner ignition (DBI) or by intermittent pilot (IP)
- Manual reset function and remote signalling of the non-volatile lockout state
- Multiple plug-in connectors
- Utilises well established electronic technology for high reliability of operations
- Precise and repeatable timings
- Multiple ignition attempts
- Flame detection by ionization
- CE approval according to EN 298 standard
- Repetition of the cycle after loss off flame during operation
- Permanent lock-out visualization, a without thermostat input being present
- Suitable for applications at wide ambient temperature range
Options available
- Fan and air pressure switch control
- Volatile lockout version for specific applications
- 230 VAC or optocoupled flame presence signal
- Possibility to connect an automatic safety thermostat in series with the
solenoid valve with manual lockout following its opening
- Different flame current sensitivity options may be specified
- Protection degree IP44
- Several pre-purge and safety timings can be tailored to the application.
- Different frequency of ignition
- Possibility of connection on phase-phase main supply power lines
2
577 DBC
OPERATION
Normal operation (natural draught or fan assisted)
BOILERS WITH
During the waiting or purge time, Tw or Tp, the unit verifies that there is NATURAL DRAUGHT
DBI version
no parasitic flame signal present, and that the internal circuitry is
operating correctly. If the unit is used on a fan-assisted application, the
air pressure switch is verified to be in the N.C. (normally closed) or MV
“no flow” position. VN
Upon powering the fan, the unit will not begin the operating sequence
until the N.O. (normally open) or “flow” position is activated on the air
pressure switch. After the scheduled waiting time Tw, or purge time Tp,
the built-in igniter and the gas valve are energized. This commences the TW TW TS
safety time, Ts. The ignition spark will ignite the gas and the flame will
be sensed by the electrode.
BOILERS WITH
If there is no flame the system repeats the ignition cycle, after a defined
NATURAL DRAUGHT
interpurge time, for a definite number of times and it goes definitively on IP version
lockout position in case there is no flame.
Upon sensing the flame, the HV spark will be suppressed and the gas
valve will remain energized. When the thermostat is open, the valve and EV1
fan are de-energized and the control returns to the stand-by mode. The EV2
safety time of the 577 DBC has a constant duration in all operating VN
conditions and, in particular, does not depend on the moment the
pressure switch is switched over.
Resetting the unit TW TW TS
To reset the unit the reset switch is depressed for one second at least and
then released. FAN ASSISTED BOILERS
DBI version
EV
WIRING DIAGRAM VN
P
TP TP TS
3
577 DBC
TECHNICAL DATA
AMBIENT WORKING TEMPERATURE
-20 °C to +60 °C
HUMIDITY
90 % max at 40 °C (not condensing)
SUPPLY VOLTAGE
230 Vac - 15 %, + 10 %, 50-60 Hz
POWER CONSUMPTION
20 VA
ELECTRICAL RATINGS
Gas valves: 230 Vac, 0.5 A, cosϕ≥0.4
Fan: 230 Vac, 1 A, cosϕ≥0.6
Alarm: 230 Vac, 1 A, cosϕ=1
ELECTRICAL CONNECTIONS
High voltage probe: male fast-on connector 2.8 x 0.5 mm
Flame detection probe: male fast-on connector 4.8 x 0.8 mm
Other connections: male Molex series 2599 suitable for female Molex series
3001 and 3002 or compatible.
PROTECTION DEGREE
Standard IP 40
IP 44 with gaskets
TIMING
Minimum waiting time Tw or purge time Tp: 1 ... 60 sec.
Maximum safety time Ts: 3 ... 120 sec.
Ignition attemps 1 ... 10
Relative interpurge time 0 ... 240 sec.
FLAME SENSING
Minimum flame current: 0.5 µA
Recommended flame current: > 3 times the minimum current
FUSING
Internal: 4 A fast.
External: maximum 3.15 A fast or less depending on the electrical loads. This
fuse protects the device in the event of overloading or short circuits and prevents
the intervention of the internal fuse.
IGNITION
Ignition voltage: 15 KV at 30 pF load
Repetition rate: 25 Hz standard (1 : 50 Hz)
Max. length of the cable: 1 m
Spark gap recommended: 2-4 mm
MOUNTING
Integrated on SIT SIGMA multifunctional gas controls.
DIMENSIONS- 577 DBC with 845 SIGMA VERSION G3/4 ISO 228
SIT GROUP
www.sitgroup.it - e-mail:
[email protected]
4