We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Sit control box 0537501 - Burner Controls
SITBurner Controls

Sit control box 0537501

Sit control box 0537501 is a burner control unit for industrial combustion systems featuring a 2-4 mm spark gap and 25 Hz repetition rate. With IP 40 protection and 2 m maximum cable length, it integrates flame…

SKU 3G-CBM-06067

Also listed as: REL 55008 · REL-55008

Brand
SIT
Item
control box 0537501
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

SIT
spark gap
2-4 mm
power factor
cosϕ=1
alarm current
1 A
alarm voltage
230 Vac
repetition rate
25 Hz
max cable length
2 m
protection degree
IP 40
high voltage probe
male fast-on connector 2.8 mm X 0.5 mm
flame detection probe
male fast-on connector 4.8 mm X 0.8 mm

Datasheet Content

SIT Group 537 ABC Subject to change without notice 537 ABC - ELECTRONIC FLAME CONTROL DEVICE FOR INTEGRAL MOUNTING ON SIT SIGMA MULTIFUNCTIONAL CONTROLS 9.955.486 108 w w w . s i t g r o u p . i t 537 ABC DESCRIPTION The 537 ABC is an electronic flame safety device for controlling a gas appliance using the principles of flame rectification. The 537 ABC automatic device has been designed for domestic gas appliances with or without a fan in the combustion circuit; with direct ignition or ignition by means of an intermittent pilot in applications which require either non-volatile or volatile lockout. The 537 ABC family of products has been specifically designed for fixing on SIT 840, 845 and 848 SIGMA multifunctional controls by means of an exclusive plastic container which integrates itself with the valve body and simplifies connection of the solenoid valves. APPLICATIONS The 537 ABC is an automatic ignition control for applications with intermittent operation in accordance with EN298 for: - boilers with natural draught - boilers with forced draught including dynamic control of the air pressure switch. NORMATIVE REFERENCE EN 298 Automatic gas burner control systems for gas burners and gas-burning appliances with or without fans. BASIC FEATURES - Compact design - Direct assembly on the gas control - Incorporated igniter - Direct burner ignition (DBI) or by intermittent pilot (IP) - Manual reset function and remote signalling of the non-volatile lockout state - Multiple plug-in connectors - Utilises well established electronic technology for high reliability of operation - Precise and repeatable timing - Flame detection by ionization - EC approval according to EN 298 standard - Repetition of the cycle after loss off flame during operation - Permanent lock-out visualization, a without thermostat input being present - Suitable for applications at low ambient temperatures Options available - Fan and air pressure switch control - Volatile lockout version for specific applications - Possibility to connect an automatic safety thermostat in series with the solenoid valve with manual lockout following its operation - Different flame current sensitivity options may be specified - Protection rating IP44 - Several pre-purge and safety timings can be tailored to the application. 2 537 ABC OPERATION Normal operation (natural draught or fan assisted) BOILERS WITH During the waiting or purge time, Tw or Tp, the unit verifies that there is NATURAL DRAUGHT DBI version no parasitic flame signal present, and that the internal circuitry is operating correctly. If the unit is used on a fan-assisted application, the air pressure switch is verified to be in the N.C. (normally closed) or MV “no flow” position. VN Upon powering the fan, the unit will not begin the operating sequence until the N.O. (normally open) or “flow” position is activated on the air pressure switch. After the scheduled waiting time Tw, or purge time Tp, the built-in igniter and the gas valve are energized. This commences the TW TW TS safety time, Ts. The ignition spark will ignite the gas and the flame will be sensed by the HV electrode. BOILERS WITH Upon sensing the flame, the HV spark will be suppressed and the gas NATURAL DRAUGHT valve will remain energized. When the thermostat is satisfied, the valve IP version and fan are de-energized and the control returns to the stand-by mode. The safety time of the 537 ABC has a constant duration in all operating EV1 conditions and, in particular, does not depend on the moment the pressure switch is switched over. EV2 VN Resetting the unit To reset the unit the reset switch is depressed. If a first reset is not TW TW TS successful, wait at least 10 seconds before the next attempt. FAN ASSISTED BOILERS DBI version WIRING DIAGRAM EV VN P TP TP TS 3 537 ABC TECHNICAL DATA AMBIENT WORKING TEMPERATURE -20 TO + 60 °C HUMIDITY 95 % max at 40 °C SUPPLY VOLTAGE 230 Vac - 15 %, + 10 %, 50-60 Hz POWER CONSUMPTION 10 VA ELECTRICAL RATINGS Gas valves: 230 Vac, 0.5 A, cosϕ≥0.4 Fan: 230 Vac, 1 A, cosϕ≥0.4 (optional) Allarm: 230 Vac, 1 A, cosϕ=1 ELECTRICAL CONNECTIONS High voltage probe: male fast-on connector 2.8 mm X 0.5 mm Flame detection probe: male fast-on connector 4.8 mm X 0.8 mm Other connections: male Molex series 2599 suitable for female Molex series 3001 and 3002 or compatible. PROTECTION DEGREE Standard IP 40 IP 44 with gaskets TIMING Minimum waiting time Tw or purge time Tp: 1.5 ... 40 sec. Maximum safety time Ts: 3 ... 60 sec. FLAME SENSING Minimum flame current: 0.5µA Recommended flame current: > 3 times the minimum current FUSING Internal: 4 A fast. External: 3.15 A fast or less depending on the electrical loads. This fuse protects the device in the event of overloading or short circuits and prevents the intervention of the internal fuse. IGNITION Ignition voltage: 15 KV at 30 pF load Repetition rate: 25 Hz standard (1 : 25 Hz) Max. length of the cable: 2 m Spark gap recommended: 2-4 mm MOUNTING Integrated on SIT SIGMA multifunctional gas controls. DIMENSIONS- 537 ABC with 845 SIGMA VERSION G3/4 ISO 228 4

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

SIT Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Sit control box 0537501 is a burner control unit for industrial combustion systems featuring a 2-4 mm spark gap and 25 Hz repetition rate. With IP 40 protection and 2 m maximum cable length, it integrates flame detection and high-voltage probe monitoring for reliable burner operation.

Frequently Asked Questions

Where can I buy the SIT 0537501 burner control box in your region?

3G Electric supplies the SIT 0537501 control box with delivery to your location. We handle all customs customs clearance and logistics. Contact us for availability and lead-time quotes.

What is the lead time and delivery timeframe for the SIT 0537501?

Lead time depends on stock location and customs processing. 3G Electric sources from our European network and arranges direct delivery to your facility in your region. Request a quote for current lead time on this model.

What flame detection specifications does the SIT 0537501 provide?

The SIT 0537501 features a 25 Hz repetition rate with 2–4 mm spark gap, IP 40 protection, and dual flame-detection probes: male fast-on connectors (4.8 mm × 0.8 mm for flame; 2.8 mm × 0.5 mm for high-voltage probe). Maximum cable length is 2 m.

Used in

Common applications for SIT
Commercial boiler gas-control replacement — Sigma 845 / 848 on hot-water and steam boilers
Catering and commercial kitchen equipment — Eurosit 630 thermostatic valves on fryers, ovens, and steamers
Residential heating appliance service — NOVA 820 / 822 / 824 as OEM-replacement gas-control valves
Standing-pilot gas appliance refurbishment — Eurosit 630 and Minisit thermostatic controls
Industrial gas-fired process equipment — Sigma 848 modulating gas valves for burner integration

SIT Products

3G Electric supplies SIT burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
SIT
SIT
Sit control box 0536007
SIT
SIT
Control box Sit 0537002
Satronic
Satronic
Relay CM391.2 10.5
Satronic
Satronic
Relay SM 152.2

More from SIT

View all SIT parts
Sit 0577211 control box
SIT
Sit 0577211 control box
SIT
SIT
Sit 0503501 control box
SIT
SIT
Sit control box 0537201
Sit 0577710 NO FAN DBI control box
SIT
Sit 0577710 NO FAN DBI control box
SIT
SIT
Sit control box 0503902
SIT
SIT
Sit 0579308 control box (replaces 0577308)
SIT
SIT
Sit control box 0537403
Control box Sit 0579311 replaces 0577311
SIT
Control box Sit 0579311 replaces 0577311