The Brahma Relay CM 11F TW1.5/TS10 is an electronic gas burner control system from the MICROFLA T Series, designed for atmospheric burners in intermittent operation. It features a completely solid and high-efficient…

SKU 3G-CBM-06038

Also listed as: REL 45160 · REL-45160

Brand
Brahma
Item
Relay CM 11F TW1.5/TS10
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Brahma
series
MICROFLA T Series
application
Atmospheric burners for intermittent operation, with or without fan in combustion circuit
control type
Electronic gas burner control system
lockout type
Non-volatile lockout with manual reset required
series types
CM.. F, SM.. F, MM.. F, TM.. F
suitable for
Combi boilers, heating boilers, warm air generators, radiant heaters, water heaters, ovens, cookers, gas firing installations with atmospheric burner
operation type
Intermittent (non-permanent)
ignition device
Completely solid and high efficient inbuilt ignition device with built-in E.M. filter
safety contacts
Two independent safety contacts in series on gas valve output
certification ce
CE Reg. N° 63AQ0625
flame monitoring
Ionization (rectification property of the flame)
auxiliary contact
For low power ignition or main gas valve control for intermittent pilot systems
fan compatibility
With or without fan
standards compliance
EN 298 (European standard for automatic gas burner control systems and flame detectors)
anti emissions filter
Built-in
compliance directives
Gas Appliance Directives 90/396 and 93/68
valve output resistor option
0–220 ohm
lockout signal resistor option
0–470 kohm

Datasheet Content

MICROFLA T SERIES TYPES CM.. F SM.. F MM.. F TM.. F AUTOMATIC CONTROL SYSTEMS FOR Application GAS BURNERS AND GAS BURNING This range of electronic gas burner control systems has APPLIANCES WITH OR WITHOUT FAN been specifically designed for atn:iospheric burners for intermittent opE:ration (systems for non-permanent AND WITH BUILT-IN ANTI-EMISSIONS operation), with or without fan in the combustion circuit. FILTER Ali these.controls are provided with non-volatile lockout, i.e. a restart from the safety shutdown condition can only be accomplished by a manual reset of the system. The automatic burner control units of this series are suîtable for: -combi boilers; -heating boilers; -warm air generators; -radiant heaters; -water heaters. Thanks to their design and variety of models, they can also be used for the automation of ovens, cookers and in gas firing installations with atmospheric burner in general. Features Table 1 shows the main features of this series. Other important features are: - EC certification (CE Reg. N ° 63AQ0625) in accordance with Gas Appliance Directives 90/396 and 93/68; - in accordance with EN 298 (European standard for automatic gas burner control systems and flame detectors); - completely solid and high efficient inbuilt ignition device with built-in E.M. filter; - possibility of mounting a resistor (0 + 220 ohm) in series to the valve output. in case the valves operate with direct current obtained through the rectification of the supply alternate current by means of one or more diodes; - possibility of mounting a resistor (0 + 470 Kohm) in series to the lockout signal output, to avoid possible damages to the control in case the connections of the reset button and the connections of the lockout signal are inverted; - two independent safety contacts in series on the gas valve output; - auxiliary contact for low power ignition or main gas valve contrai for intermittent pilot systems; this contact is not isolated from the main supply voltage by reinforced isolation, therefore the relay contact is not suitable to supply SELV circuits - Safety Extra Low Voltage, e.g.24V; - flame monitoring by the rectification property of the flame: ionization. .!,f r-:-t ...- . . . - .: - -������L-,,t'-.- � .........i....., ·--=.:. . .·- -"'....

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Brahma Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Brahma Relay CM 11F TW1.5/TS10 is an electronic gas burner control system from the MICROFLA T Series, designed for atmospheric burners in intermittent operation. It features a completely solid and high-efficient built-in ignition device with integrated E.M. filter, ionization-based flame monitoring, two independent safety contacts in series on the gas valve output, and non-volatile lockout with manual reset. Suitable for combi boilers, heating boilers, warm air generators, radiant heaters, water heaters, ovens, cookers, and gas firing installations, it operates with or without fan in the combustion circuit and complies with EN 298, Gas Appliance Directives 90/396 and 93/68, and carries CE certification (Reg. N° 63AQ0625). 3G Electric sources and supplies this control system for SE Asia and Singapore markets with full DDP delivery.

Frequently Asked Questions

Where can I buy the Brahma Relay CM 11F burner control in your region?

3G Electric supplies the Brahma Relay CM 11F (part REL45160) with delivery to your location. We handle all customs import clearance, logistics, and USD invoicing. Contact us for lead times and quotation.

What is the lead time for the Brahma Relay CM 11F TW1.5/TS10?

Lead time varies by availability. The Brahma Relay CM 11F is available to order through 3G Electric. Delivery to your location is arranged with full customs clearance handled by our logistics team.

What applications is the Brahma Relay CM 11F suitable for?

The Brahma Relay CM 11F is designed for atmospheric burners in intermittent operation, with or without fan in the combustion circuit. It supports combi boilers, heating boilers, warm air generators, radiant heaters, and water heaters with ionization-based flame monitoring.

Used in

Common applications for Brahma
Italian light-oil burner ignition — T11 transformer as scheduled-maintenance replacement
Heavy-duty industrial burner racks — T15 / T18 / T36 for high-spark-energy applications
Combustion control-card swaps — CM31N / CM32N / CM391 onto existing Brahma-equipped burners
UV flame-detection retrofits — upgrading older photocell-based detection to solid-state UV
Safety-relay scheduled replacement — SRE / SM / FDB series on commercial gas / oil burners

Brahma Products

3G Electric supplies Brahma burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Brahma
Brahma
Relay CM 11F TW1.5/TS5
Relay CM 31 F TW1.5/TS10
Brahma
Relay CM 31 F TW1.5/TS10
Relay CM 31 TW1.5/TS10
Brahma
Relay CM 31 TW1.5/TS10
Relay CM 31F TW10/TS5
Brahma
Relay CM 31F TW10/TS5
Relay TM 11 TW1,5/TS10
Brahma
Relay TM 11 TW1,5/TS10
Relay CM 32 TW1.5/TS10
Brahma
Relay CM 32 TW1.5/TS10

More from Brahma

View all Brahma parts
Relay MM 192.4 TW5/TS10
Brahma
Relay MM 192.4 TW5/TS10
Relay G 22 S03N TV15/TS10
Brahma
Relay G 22 S03N TV15/TS10
Relay CM 31 F TW10/TS5
Brahma
Relay CM 31 F TW10/TS5
Relay RE3 SP
Brahma
Relay RE3 SP
Relay CM 31 TW30/TS10
Brahma
Relay CM 31 TW30/TS10
Brahma
Brahma
FC 7/R cell
Brahma
Brahma
Relay GE 733
Brahma
Brahma
Relay GE 735