We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Brahma Relay G 22 S03N TV15/TS10 - Burner Controls
BrahmaBurner Controls

Brahma Relay G 22 S03N TV15/TS10

Brahma Relay G 22 S03N TV15/TS10 is an oil burner control unit operating at 220V, 110V, 24V, or 12V supply voltages. It features a 10 A fast-blow fuse for 24V/12V circuits and 4 A fast-blow fuse for 220V/110V…

SKU 3G-CBM-05970

Also listed as: REL 40102 · REL-40102

Brand
Brahma
Item
Relay G 22 S03N TV15/TS10
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Brahma
application
oil burner control
fuse 24V 12V
10 A fast-blow
motor rating
2.0 A cosφ > 0.4
fuse 220V 110V
4 A fast-blow
supply voltage
220V, 110V, 24V, 12V
thermostat rating
6.0 A cosφ > 0.4
weight including base
240 g
ignition transformer rating
2.0 A cosφ > 0.4

Datasheet Content

CONTROLLERS TYPES G.. OR.. Series 03N AUTOMATIC CONTROL SYSTEMS FOR OIL BURNERS APPLICATION The electro-mechanical controllers of this series are designed to control oil burners in non-permanent applications. These controllers are suitable for : − monoblock burners − power washers − hot air generators − steam boilers − furnaces Due to the models technical and constructive features and to their variety they can be used also for the automation of cookers, and of plants employing oil burners generally, whether in domestic or industrial applications. These controllers replace integrally the 03 electro-mechanical series FEATURES Table 1 shows the main features of this series. Other important features are: − two independent safety contacts for valve driving − electrical service life at max. declared load > 250.000 operations; − Easy installation and connection. TABLE 1 Lockout due to extraneous light (2) Thermal range< 30kg/h Thermal range> 30kg/h FC7/. FC8/ photocells FC11/. FC13/.photocells Single flame Dual flame preheater (1) Pre-ignition G22 * * * * * * GF2 * * * * * GF3 * * * * * OR1 * * * * * * OR2 * * * * * OR3 * * * * * (1) Application is possible with appropriate connection (2) Function is available only in controllers with 12V and 24V supply voltage and GF2 220V and 110V 13697_r00 1/5 CONNECTION TECHNICAL DATA The connection bases type B and N can be provided to connect the external components to the controller (see Fig. Power supply : 220V 50/60Hz 2). Both bases are provided with screw terminals which Upon request: 110V 50/60Hz allow a safe and easy connection. It’s advisable to use M4 24V dc and ac 50/60Hz screw for fastening purpose. 12V dc and ac 50/60Hz Operating temperature -10°C ÷ +60°C Protection degree (with base) IP 40 Times – Pre-purge time (TV @ 20°C): 15/20 s – Safety time (TS @ 20°C): 5/10 s – Response time in case of flame failure: <1s Power consumption (@220V-50Hz): 6,5 VA (@12V/24V ): 1VA Internal Fuse – For 220V e 110V supply voltage: 6,3 A time-delay – For 24V e 12V supply voltage: 10 A time-delay External fuse – For 220V e 110V supply voltage: 4 A fast-blow – For 24V e 12V supply voltage: 10 A fast-blow Weight including connection base: about 240 g Max. contacts rating (@220V): Imax Fig.2 – Thermostat: 6,0 A cosϕ > 0,4 – Motor: 2,0 A cosϕ > 0,4 ACCESSORIES – Ignition transformer: 2,0 A cosϕ > 0,4 The following indications must be considered in order to – EV1: 0,5 A cosϕ > 0,4 choose the suitable flame detector for the controller and the application type: – EV2: 0,5 A cosϕ > 0,4 – Preheater: 0,5 A cosϕ = 1,0 Controller Type Photocell – Lockout signal: 1,0 A cosϕ = 1,0 - G22, GF2, GF3 Max. contacts rating (@12V e 24V): Imax FC8/R 1,5..5,5 lux – Thermostat: 10 A cosϕ > 0,4 Frontal side FC8/A 1,5..3,0 lux – Motor: 4,0 A cosϕ > 0,4 FC8/V 5,5.. 10 lux – Ignition transformer: 3,0 A cosϕ > 0,4 – EV1: 1,5 A cosϕ > 0,4 FC7/R 1,5..5,5 lux – EV2: 1,5 A cosϕ > 0,4 Lateral side FC7/A 1,5..3,0 lux – Lockout signal: 1,0 A cosϕ = 1,0 FC7/V 5,5…10 lux - OR1, OR2, OR3 CONSTRUCTION Frontal and lateral side FC11/R* 1,5..6,5 lux The plastic enclosure protects the controller against mechanical damage caused by crash, tempering , dust and Frontal and lateral side FC13/R 1,5..6,5 lux dirt of external ambient. An inbuilt fuse protects the FC13/A 1,5..3,0 lux controller internal relays in case of short circuit on the outputs (valves, fan and lockout signal); * The FC11/R is provided with a black plastic enclosure only The suffix indicates the colour of the photocell enclosure: /R red OVERALL DIMENSIONS /A blue Fig1 shows the controller overall dimensions /V green FC7 FC8 drilling plane FC13 drilling plane FC11 drilling plane Base type dimensions h B 99 N 98.3 Fig.1 Fig. 3 Fig. 4 2/5 13697_r00 The figures (Fig.3) show the types and fixing systems of CHECKING AT START the available flame detectors. Before any ignition attempt make sure that the combustion 4 mm diameter screws are suggested To fix the flame chamber is free from oil, then make sure that: detector. − if the starting attempt occurs with the flame detector Core hitches and Strain relieves can be fitted on the sides obscured the controller performs a lockout at the end of of the controllers enclosures and the connecting bases. safety time; These accessories can be supplied upon request (see − if start up attempt occurs with extraneous light, the Fig.5). controller proceeds to lockout within the time equivalent to safety time (only in versions where this option is available) ; − when the flame detector is obscured in running position the oil valve(s) is/are de-energized within 1 second, and the controller goes to lockout after a recycle; The intervention of regulators, limiters or safety devices causes a shut down of the controller according to the Fig.5 application type; − Operating times and cycle are in compliance with the INSTALLATION DIRECTIONS ones declared for the used controller type. − The controllers are safety devices; guarantee and responsibility of the manufacturer will be debarred if the products are tempered with by the user;. OPERATION − Make sure that a regulation shutdown occurs every 24 Once the thermostats are closed, the controller energizes hours to allow the controller self-checking its efficiency the burner motor; in this phase the device proceeds to a (non permanent operation systems). self-checking process of the flame detection and safety − The controller must be connected and disconnected circuit. At the end of pre-purge time the output of the first oil without power supply. valve is powered. If flame is detected, at the end of safety − The controller can be mounted in any position. time, the controller de-energizes the ignition transformer − Avoid exposure to dripping water. and goes to running position. − A ventilated installation ambient and a quite low At the end of safety time, in the double stage controllers, temperature ensure the longest life of the controller…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Brahma Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Brahma Relay G 22 S03N TV15/TS10 is an oil burner control unit operating at 220V, 110V, 24V, or 12V supply voltages. It features a 10 A fast-blow fuse for 24V/12V circuits and 4 A fast-blow fuse for 220V/110V circuits, with thermostat rating of 6.0 A. The complete unit weighs 240 g and integrates ignition control for industrial heating applications.

Frequently Asked Questions

Where can I buy the Brahma Relay G 22 S03N TV15/TS10 burner control in your region?

3G Electric supplies the Brahma Relay G 22 S03N TV15/TS10 for delivery to your location. We handle all customs documentation and logistics. Contact us for availability and to obtain a formal quotation with USD invoicing.

What is the lead time for the Brahma Relay G 22 S03N TV15/TS10?

Lead time is available on request. 3G Electric sources this Brahma control relay to order and manages full customs clearance for delivery throughout your region. Confirm your project timeline when requesting a quote.

What supply voltages does the Brahma Relay G 22 S03N support?

The Brahma Relay G 22 S03N TV15/TS10 operates at 220V, 110V, 24V, or 12V supply voltages. It includes a 10A fast-blow fuse for 24V/12V circuits and a 4A fast-blow fuse for 220V/110V circuits. The thermostat rating is 6.0A cosφ > 0.4.

Used in

Common applications for Brahma
Italian light-oil burner ignition — T11 transformer as scheduled-maintenance replacement
Heavy-duty industrial burner racks — T15 / T18 / T36 for high-spark-energy applications
Combustion control-card swaps — CM31N / CM32N / CM391 onto existing Brahma-equipped burners
UV flame-detection retrofits — upgrading older photocell-based detection to solid-state UV
Safety-relay scheduled replacement — SRE / SM / FDB series on commercial gas / oil burners

Brahma Products

3G Electric supplies Brahma burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Relay G22/Z S10
Brahma
Relay G22/Z S10
Relay VM44G TV20 TS3
Brahma
Relay VM44G TV20 TS3
Relay VM 42 TV20 TS3
Brahma
Relay VM 42 TV20 TS3
Relay G 22 S10 220V
Brahma
Relay G 22 S10 220V
Relay VM44G TV5 TS3
Brahma
Relay VM44G TV5 TS3
Relay GF 2/03
Brahma
Relay GF 2/03

More from Brahma

View all Brahma parts
Relay MM 192.4 TW5/TS10
Brahma
Relay MM 192.4 TW5/TS10
Relay CM 31 F TW10/TS5
Brahma
Relay CM 31 F TW10/TS5
Relay RE3 SP
Brahma
Relay RE3 SP
Relay CM 31 TW30/TS10
Brahma
Relay CM 31 TW30/TS10
Brahma
Brahma
FC 7/R cell
Brahma
Brahma
Relay GE 733
Brahma
Brahma
Relay GE 735
Brahma
Brahma
Relay GR1 10.10