We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Brahma Relay SM 192.2 - Burner Controls
BrahmaBurner Controls

Brahma Relay SM 192.2

Brahma Relay SM 192.2

SKU 3G-CBM-06011

Also listed as: REL 45131 · REL-45131

Brand
Brahma
Item
Relay SM 192.2
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Brahma
type
SM 192.2
application
automatic gas burner control

Datasheet Content

EUROBOX SERIES TYPES CM... SM... MM... Application AUTOMATIC GAS BURNER CONTROL This range of electronic gas burner contrai systems has SYSTEMS FOR GAS BURNERS AND GAS been designed specifically for atmospheric and fan assisted BURNING APPLIANCES WITH OR burners for intermittent operation (systems for non­ WITHOUT FAN permanent operation ). Ali these contrais are provided with non-volatile lock-out, which means that a restart from the safety shut-down condition can only be accomplished by a manual reset of the system. The automatic burner contrai units of this series are suitable for: -combi boilers -heating boilers -warm air generators -radiant heaters -water heaters Due to the design and the variety of models they can be used also for the automation of ovens, cookers and in general in gas firing installations with atmospheric burner. Features Table 1 shows the main features of this series. Other important features are: - EC - Type certification (CE Reg. N° 63AQ0625) in accordance with Gas Appliance Directives 90/396 and 93/68; - in accordance with EN298 (European standard for automatic gas burner contrai systems); - flame monitoring by the rectification property of the flame: ionization; - two independent safety contacts in series on the gas valve output; - electrical service lite at max. loading >250.000 operations; - inbuilt or remote reset facility; - inbuilt ignition device completely of solid state design and high efficiency; - auxiliary contact for low power ignition or main gas valve contrai for intermittent pilot systems (this contact is not isolated from the main supply voltage by reinforced isolation, therefore the relay contact is not suitable to supply SEL V circuits - Safety Extra Low Voltage, e.g. 24V); - different connections and fixings. TABLE 7 BORNER RESET CONNECTION c O N C 7 O ao L L V N O V ~ Û w d U U ~ ~ 'Ç ~ O O — E a L a L a ~ ~ m d ~ ô ~ O v c :~ a ~ z ~ î ~ d O O ~ ~ ~ O ~ ~n O Ÿ Ÿ Ÿ Ÿ ~ ~ ~ ~ ~ ~ X ~ ~ p û U U U U ~O LI O Q N d = U O N N tin (fin CM 197 (B) (A) AMCLXN SM 191 (A) AMCLXN SM 192 (B) (A) AMCLXN CM 381 (B) (A) FMCLXN CM 391 (A) FMCLXN SM 152 (B) (A) AMCLXN SM 592 (B) (A) AMCLXN MM 797 (B) (A) AMCLXN MM 192 ~ (B) (A) AMCLXN NOTE: (A) Box type xxxxx.1 - xxxxx.2 (1):This contact is not isolated from the main supply voltage by reinforced (B) Box type xxxxx.3 - xxxxx.4 isolation, therefore the relay contact is not suitable to supply SELV circuits - Safety Extra Low Voltage, e.g. 24V. (2) : Flame failure during TS causes spark restoration. TECHNICAL DATA -Minimum ionization current: 1.2E~A Supply Voltage: 230V-50/60Hz on request: 0.5µA on request: 110/120V-50/60Hz -Recommended ionization current: 3 = 5 times the Operating temperature range: -20°C +60°C minimum ionization current Amblent humidity: 95% max at 40°C -Max. length of the Gable: 1m Protection degree: -Minimum insulation resistance of Gable and flame detector socket NG: IP 40 (alter installation) device to Barth: z 50M52 socket P/R IP 00 -Max. parasitic capacitance of Times: detection probe: s 1 nF -Prepurge or waiting time (TW): 1,5/3/5/10/20/30/40 s -Max. short circuit current: < 200E~A AC -Safety time (TS): 3/5/8/10/20/30/40/50/60 s Ignition: -Drop out time on running flame failure: <1s -Ignition voltage: 8 KV at 30pF loading The times given on the burner control label correspond to -Repetition rate: 25 Hz the values guaranteed. The actual values differ slightly from -Max.length of the Gable: 2m the values given, pre-purge and waiting times are in fact -Spark gap recommended: 2-4 mm longer and safety time shorter than their nominal values. -Consumption: 2,5 VA Power cônsumption, at starting up: -Spark energy: 15 mJ atmospheric burner 10 VA Weight: atmospheric fan-assisted burner 12 VA -with socket P or R: 220 g Power consumption, running: -with socket NG or MG: 275 g atmospheric burner 7 VA Controls for special applications: atmospheric fan-assisted burner 9 VA On request it is possible to meet special requirements Contact rating: I max concerning times, repetition rate of the sparks, minimum -Thermostat: 4 A cos cp = 0.4 ionization current and operating cycle. -EV1: 0.5A coscp =0.4 CONSTRUCTION -EV2: 0.5 A cos cp = 0.4 The enclosure made of plastic material protects the control -EVG: 0.5 A cos cp = 0.4 from mechanical damage, dust and dirt from the conditions -Fan: 1 A cos cp = 0.4 of installation.The particular construction, consisting of four -Alarm: 0.5 A cos cp = 1 printed circuit boards in order to forma "box" structure, has -Auxiliary contact: 0.5 A cos cp = 0.4 allowed a reduction in the volume of the control unit. -Externat ignition: 1.5 A cos cp = 02 A varistor protects the control from voltage transients on the Max. length of the Gables of mains supply. An internat fuse protects the relays of the externat components: 1 m control box in case of short circuits on the outputs (valves, Fuse rating internat: 4 A Fast fan and lock-out signal). This is not an accessible fuse and Fuse rating externat: 3.15 A Fast the control must be protected with a fuse of the fast blow Flame control: type suitable to the Joad connected and never exceeding The ionization flame detector device makes use of the 3.15A. rectification property of the flame. Overall Dimensions The ionization flame detector device is not a safe to touch The control units of the EUROBOX series Gan be supplied output (no provision, with protective impedances). with different executions of the enclosure depending on the functions and the fixing system required. Enclosures are available with or without reset button and screw terminal suitable for the CM381 control unit. Socket can be provided or not with fixing brackets on the sides. type P differentiates from type R on positions 8…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Brahma Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Brahma Relay SM 192.2

Frequently Asked Questions

Where can I buy Brahma SM 192.2 relay in your region?

3G Electric supplies Brahma SM 192.2 relays with delivery to your location. We handle all customs clearance, customs documentation, and USD invoicing. Contact us for lead times and pricing.

What is the lead time for Brahma SM 192.2 relay?

Lead time on request. 3G Electric sources the SM 192.2 directly and manages import logistics to your region. Delivery timelines depend on current availability — contact our team for a quote.

What does the Brahma SM 192.2 relay control?

The SM 192.2 is a relay for automatic gas burner control applications. It integrates with gas burner systems requiring reliable on-off and modulation control. Verify compatibility with your burner model before ordering.

Used in

Common applications for Brahma
Italian light-oil burner ignition — T11 transformer as scheduled-maintenance replacement
Heavy-duty industrial burner racks — T15 / T18 / T36 for high-spark-energy applications
Combustion control-card swaps — CM31N / CM32N / CM391 onto existing Brahma-equipped burners
UV flame-detection retrofits — upgrading older photocell-based detection to solid-state UV
Safety-relay scheduled replacement — SRE / SM / FDB series on commercial gas / oil burners

Brahma Products

3G Electric supplies Brahma burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Relay SM 11
Brahma
Relay SM 11
Relay SM 192.2 TW1.5/TS5
Brahma
Relay SM 192.2 TW1.5/TS5
Relay CM 11
Brahma
Relay CM 11
Relay CM 11F
Brahma
Relay CM 11F
Relay CM 11F
Brahma
Relay CM 11F
Relay DTMN31 PR
Brahma
Relay DTMN31 PR

More from Brahma

View all Brahma parts
Relay MM 192.4 TW5/TS10
Brahma
Relay MM 192.4 TW5/TS10
Relay G 22 S03N TV15/TS10
Brahma
Relay G 22 S03N TV15/TS10
Relay CM 31 F TW10/TS5
Brahma
Relay CM 31 F TW10/TS5
Relay RE3 SP
Brahma
Relay RE3 SP
Relay CM 31 TW30/TS10
Brahma
Relay CM 31 TW30/TS10
Brahma
Brahma
FC 7/R cell
Brahma
Brahma
Relay GE 733
Brahma
Brahma
Relay GE 735