SatronicBurner Controls

Satronic Relay G22 S09

Satronic Relay G22 S09 is a burner control module for fuel-fired heating systems. It features external fuse rating of 4.0 A fast and internal fuse rating of 6.3 A slow blow, with ignition safety times of 10 seconds…

SKU 3G-CBM-05975

Also listed as: REL 40109 · REL-40109

Brand
Satronic
Item
Relay G22 S09
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Satronic
external fuse rating
4.0 A fast
internal fuse rating
6.3 A slow blow
max heat input 30kg h
ignition safety time 10 seconds
max heat input 100kg h
ignition safety time 5 seconds

Datasheet Content

EURO-OIL SERIES TYPE G22 series 09 AUTOMATIC OIL BURNER CONTROL APPLICATION SYSTEMS This range of electronic oil burner controls has been specifically designed for oil burners for non permanent operation. The automatic burner controls of this series are suitable for: − monobloc oil burners − warm air generators − steam boilers − power washers − kilns Due to the technical and structural characteristics and to the variety of models they can be used for the automation of cookers and oil burner operated appliances for domestic and industrial applications. FEATURES The G22 series 09 oil burner controls, simple wiring and installation. The main features of this series are following: − for non permanent operation; − for one-stage oil burners (single flame); − prearranged for appliances with pre-heater (see “CONNECTION DIAGRAMS”); − maximum heat input according to the European standard EN 267:1999-09: - ≤ 30 kg/h (max. ignition safety time 10 seconds) - > 30 ≤ 100 kg/h (max. ignition safety time 5 seconds) the pre-purge time has to be set in compliance with nominal fuel throughput of the burner; − in accordance with the European standard DIN EN 230:1991-05 concerning monobloc oil burners, safety control and regulation devices. The DIN registration number relevant to this series of devices is the following: 5F165/04 − in compliance with the standard DIN 4794 part 2, edition December 1980 regarding warm air generators WLE (only version with TV = 20s and TS = 5s); − operation with flame detector type FC7/FC8; − two independent safety contacts for oil valve(s) control; − electrical service life at max load >250.000 operations; − simple wiring and installation. 5779_r00 1/4 TECHNICAL DATA and reliable connection. To fix the socket it is advisable to Supply Voltage: 220/240V 50/60Hz use screws type M4. To fix the control to the socket use the on request: 110/120V 50/60Hz pin supplied with the control box. Operating temperature range: -20°C +60°C Ambient humidity: 95% max at 40°C Protection degree: IP 40 Times - Pre-purge time (TV) 1,5/10/20/30/40 s - Ignition safety time (TS) 5/10 s - Dropout time on running flame failure: < 1s The times given on the burner control label correspond to the values guaranteed. The actual values slightly differ from the values given, as prepurge time can be longer and safety time shorter than their nominal values. Power consumption: 8 VA Contact rating: I max - Thermostat: 6.0 A cosϕ > 0,4 - Motor: 2.0 A cosϕ > 0,4 - Ignition transformer: 2.0 A cosϕ > 0,4 - EV1: 0.5 A cosϕ > 0,4 - EV2: 0.5 A cosϕ > 0,4 - Pre-heater: 0.5 A cosϕ = 1,0 - Alarm: 1.0 A cosϕ = 1,0 Internal fuse rating: 6.3 A slow blow External fuse rating: 4.0 A fast Weight (including socket): 132 g Fig.2 CONTROLS FOR SPECIAL APPLICATIONS On request it is possible to meet special requirements For the electrical connection of the external devices see concerning times and operating cycles. “CONNECTION DIAGRAMS”. CONSTRUCTION ACCESSORIES The particular construction and the use of the surface The following data are useful to choose the most suitable mounted components allow to have reduced overall flame detector for the appliance and the control box used: dimensions. • for traditional burners (yellow flame burners) the The enclosure made of plastic material protects the control following photocells are suitable: from possible damages resulting from crashes, incautious FC8/R 1,5..5,5 lux opening, dust and contact with the external environment. frontal side FC8/A 1,5..3,0 lux A varistor protects the control from voltage transients on the FC8/V 3,0..5,5 lux electric network. An inbuilt fuse protects the internal relays of the control box FC7/R 1,5..5,5 lux in case of short circuit on the outputs (valves, ignition lateral side FC7/A 1,5..3,0 lux transformer, motor and lockout signal). FC7/V 3,0..5,5 lux The suffix indicates the colour of the photocell enclosure: OVERALL DIMENSIONS /R red The following figure (Fig.1) shows the overall dimensions of /A blue the control. /V green Drilling plane FC7 FC8 FC8 FC7 Fig.3 Fig.1 CONNECTION The figures (Fig.3) show the types and fixing systems of the For the connection of the external components the control available flame detectors. box is delivered with socket type N (see Fig. 2). The socket is To fix the flame detector screws diameter 4 are suggested. provided with a screw terminal board which allows a simple 2/4 5779_r00 Cable holders and core hitches can be fitted on the sides of OPERATION the enclosure and the connecting sockets. These At every start the control unit supplies the burner motor and accessories can be supplied upon request (see Fig.4). the ignition transformer and proceeds to a self-checking of its own components. During the pre-purge time TV the internal circuit makes a test of the flame signal amplifier circuit. Extraneous light or a fault in the amplifier cause the lockout of the control within 10 seconds. At the end of pre-purge time the oil valve output is supplied; if a flame signal is detected at the end of safety time, the control unit deenergizes the Fig.4 ignition transformer and goes to running position. If no flame signal is detected during safety time, the control goes to DIRECTIONS FOR USE lockout, the control outputs of the valve, the ignition transformer and the burner motor are switched off while the − Automatic controls are safety devices and must not be lockout signal output is supplied. The controls prearranged opened. The manufacturer’s responsibility and guarantee are invalidated if the control is incautiously opened. for the use of an oil pre-heater supply the pre-heater when the room thermostat and/or the boiler one switch off. In this − For safety reasons a regulation shutdown must occur way the starting sequence begins. The thermostat opening every 24 hours (systems for non permanent operation). causes the repetition of the starting sequence after the − The control has to be connected and disconnected only heating stage (RISC) of the pre-heater. The attached without the mains power. diagrams are useful to understand how each control − The control can be mounted in any position. operates. − Avoid exposing the control unit to dripping water. − Ventilation and the lowest temperature ensure the Abnormal operation - Extraneous light longest life of the control. All control boxes of this series perform a lockout within 10 − Make sure that the type (code and times) you are using is seconds. correct before installing or replacing the control. RESET OF THE CONTROL ELECTRICAL INSTALLATION When a control has gone to lockout, a delay of 5 seconds − The applicable national and European standards (e.g. EN should be considered before attempting to reset the control 60335-1/EN 50165) regarding electrical safety must be unit; if this time is not observed the control may not reset. respected. − Phase and Neutral should be connected correctly; a TESTING THE FLAME SIGNAL mistake could cause a dangerous situation, as the It is extremely important to test the flame signal level before internal safety devices can be ineffective in case the having the burner operate. connecting wires of thermostats and valves are not Arrange one cable connected to terminal…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Satronic Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Satronic Relay G22 S09 is a burner control module for fuel-fired heating systems. It features external fuse rating of 4.0 A fast and internal fuse rating of 6.3 A slow blow, with ignition safety times of 10 seconds at 30 kg/h and 5 seconds at 100 kg/h. Suitable for industrial combustion applications requiring reliable ignition control.

Frequently Asked Questions

Where can I buy a Satronic Relay G22 S09 burner control in your region?

3G Electric supplies the Satronic Relay G22 S09 for delivery to your location. We handle all customs documentation and logistics. Contact us for availability and USD invoicing.

What is the lead time for the Satronic Relay G22 S09 (REL40109)?

Lead time on request. 3G Electric sources this burner control module and arranges delivery to your region. We manage customs clearance and provide full documentation support for your procurement.

What are the fuse ratings and ignition safety times for the Satronic Relay G22 S09?

External fuse rating is 4.0 A fast, internal fuse is 6.3 A slow blow. Ignition safety time is 10 seconds at 30 kg/h and 5 seconds at 100 kg/h fuel input. Suitable for industrial fuel-fired heating systems.

Used in

Common applications for Satronic
Steam boiler systems — Satronic MZ770S photocell and ZT870 transformer for flame detection and ignition control.
Industrial gas furnaces — Satronic IRD820 infrared photocell and control modules for continuous flame supervision during high-temperature processes.
Oil and gas burner retrofit — Satronic replacement photocell connectors and transformers for upgrading legacy burner safety systems.
Commercial heating equipment — Satronic burner control assemblies in air heaters and unit heaters for building HVAC systems.
Process heater automation — Satronic flame-fail relays and photocell harnesses in thermal-oil and hot-water heating loops.
Preventive maintenance programs — Satronic spare-parts kits stocked for scheduled photocell and transformer replacement in high-availability industrial facilities.

Satronic Products

3G Electric supplies Satronic burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Satronic
Satronic
Relay GF2 S10
Satronic
Satronic
Relay CM391.2 10.5
Satronic
Satronic
Relay TF 844
Satronic
Satronic
Relay SM 152.2
Satronic
Satronic
Relay TF 974
Satronic
Satronic
Relay LME 41 054C2

More from Satronic

View all Satronic parts
Satronic
Satronic
Relay CM 391-2 Frisquet
High sensitivity UV bulb
Satronic
High sensitivity UV bulb
Satronic
Satronic
IRD 1020 cell axial blue (oil and gas)
Relay RMO 8853 C2
Satronic
Relay RMO 8853 C2
Satronic
Satronic
Relay DMG 970-N MOD.03
Satronic
Satronic
Relay SM 592.2 TW1.5/TS5
Satronic
Satronic
Relay CM 381N.4 TW5/TS5
Satronic
Satronic
Relay MG569-BWZG (replaces 568 SE)