CBM electronic thermometer with K-type thermocouple sensor for industrial temperature measurement and monitoring. Alkaline battery provides 200 hours of operation, compliant with JIS 006P and IEC BF22 standards…

SKU 3G-CBM-04561

Also listed as: MES 05050 · MES-05050

Brand
CBM
Item
Electronic thermometer & kit
Category
Measurement & Detection
UNSPSC
41112412 — Pressure gauge
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

CBM
type
digital thermometer
sensor
K-type thermocouple
battery type
alkaline
battery life hours
200
temperature standard
JIS 006P or IEC BF22

Datasheet Content

DIGITAL THERMOMETER INSTRUCTION MANUAL THERMONETER | WK Gg Hl i | ||_28 | Unit and Sign Display : « Decimal point *F: Fahrenheit temperature scaie C : Celsius temperature scale : Low Battery — : Negative polarity [HOLD] : Data hold MAX : Max hold Over Range Indication : "OL" appears on the display. Low Battery Indication: The Luk is displayed when the battery voltage drops below the operating voltage. Display Rate : Approximately 2.5 times per second. Power Requirement : 9-Volt battery , NEDA 1604 or JIS OO6P or IECBF22 Battery Life ( typical ): 200hours ( Alkaline Batiery ) Dimensions: 135 (L) x 72(W) x 31(H)mm 5.3 (L) x 2.8(W) x 1.2(H)inches Weight: Approx. 235g with battery Accessories: Battery, Instruction Manual. Holster ( option } I. INTRODUCTION : This instrument is a digital thermometer’ for use with any k-type thermocouple as temperature sensor. Temperature indication follows National Bureau of Standards and 1EC584 temperature / voltage tables for K-type thermocouples. I. SPECIFICATIONS ; 2-1 Electrical Specifications Measurement Range : -50°C to 1300°C /-50°F to 1999°F Resolution: 0.1°C ,1C ,0:0F ,1°F Maximum Voltage at Thermocouple Input :60V de jor 24Vrms-ac RF Field Derating :Strong RF fields and low-frequency adversely affect accurate measurement . Environmental : Operating Temperature and Humidity: OC to 50°C (32°F to 122°F ) 40 - 8096RH Storage Temperature and Humidity: 10°C to60C (14°F to 140°F ) 10 - 709%6RH Basic Accuracy: {@23+ 5°C Calibration ) Accuracy aret (...% of reading + ..degree ) at 18°C to 28°C with relative humidity up to 80% 1 | | UL NAME OF PARTS AND POSITIONS <> see im 8 a For single thermocouple measurements Function .| Resolution Range Accuracy | Output Signal O17 | 50°C ~199.9 [z (0.3% +1C) [F (0.3964+2mv) 50C~1000C [+ (0.596+1C) | 1001°C ~1300% J+ (0.75% +1'C) -50F~| 0.1°F |-50°F~199.9°F |£ (0.396+2°F) | (0.596+5mv) 1999F | 1F | -S0°F~1999°F [+ (0.596+2°F) [# (0.75% +0.5mV) 50°C ~ 1300°C 1C c jt (0.75% +0.2mv) NOTE The basic accuracy specification does not include the error of the probe. please refer to the probe accuracy specification for additional details. Temperature Coefficient: For ambient temperatures from 0°C to 18°C and 28°C to 50° (32°F to 64°F and 82°F to 122°F ) Foreach ( °F ) ambient below 18°C (64°F ) or above 28°C ( 82°F ), add to the accuracy specifications: 0.01% of reading + 0.03°C (0.01% of réading + 0.06°F ) 2-2 General Specifications Numerical Display : 3 1/2 digital liquid crystal display (LCD ) 44mm height. maximum reading 1999. 2 @ LCD Display: 3.1/2 digits with a maximum reading of 1999, and indications or minus sign “—”, Data hold } » MAX HOLD “MAX”. “71”, “T2", “T1- T2”, F”, low battery etc. @ ON/OFF Switch: The ON/OFF Key tums the thermometer on or off. @ MAX HOLD Button : A Push Button (Push on/push off, push on :LCD appear MAX sign) @ HOLD: Pressing the HOLD key selects DATA HOLD mode. and "HOLD " symbol appears on the display. Pressing the HOLD key again cancels HOLD mode, and causes the thermometer to resume taking measurements. © Thermocoupie Input Connector. © 0.1" :Pressing the 0.1 key selects 0.1 degree resolution. Range from > to 199.9°C: or.-50°F to 199.9°F 7° cPressing the 1’ key selects 1 degree resolution Range from -50.0°C to. 1300°C or -50'F to 1999°F @ Fc. The FC key switches between the Celsius (‘C) and Fahrenheit (F)'scales on the display. T: The OFFSET controls allow you adjust offset value io optimize measurement accuracy for a particular ihermecouple at a particular. The OFFSET Controls are adjusted using a small screwdriver. 5 --- PAGE BREAK --- SD OUTPUTS: OUTPUTS from standard 3 pole 3.5ram Coaxial socket with DC+ on pin, and intermediate. {Internal Connector Pin and intermediate }, Ground on Sleeve. [Fig2} AmVde/ C CF). at 01 /0.1F resolution. OQimVde/ °C (CF). wat 1C/ 14°F. resolution. Output Impedance 502 DB Tilt stand GROUND DC+ OUTPUT [Fig 2} 6 TP-K01: Available for general condition, especially for complex and any piace hard to reach. TP-KO3: Available for flat or curved surface measurement. = = \ IVY. TEMPERATURE MEASUREMENT | 1. Turn on the thermometer. 2. Plug the thermocouple inte the thermocouple input connector. 3. Set the thermometer to desired function ¢ C or F scate & 0.1" or 1 resolution ) 4, Perform measurements by contacting the object being measured with the probe sensor. 5. Read the temperature on the display. WARNING Toavoid electrical shock,do not use this instrument when voltages exceeding 24V AC or 60V DC are present. The probe tip is electrically connected to the output terminals. Vv. ERROR INDICATION The “OL" is display if any of the following conditions occurs: 1. lf no thermocouple is plugged into the thermocouple input connector. 2. If the thermocouple connected to the input is broken or open circuited. [VL RECALIBRATION PROCEDURE: | The thermometer should be calibrated once a year fo ensure its accuracy is within specifications. The required equipmentis listed below : D0.0C: adjust VR1 @00F adjust VR2 @165.0F adjust VRS @ 952°F adjust VR4 @ 511°C adjust VR3 © OUTPUTS 0.0mVBC adjust VR7 (at 0:0°C) VIL OPTIONAL ACCESSORY K {CA ) type thermocouple. [ Model [Range [Tolerances [Description | ith Tefion tape insulation. laximum insulating 60T

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CBM Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

CBM electronic thermometer with K-type thermocouple sensor for industrial temperature measurement and monitoring. Alkaline battery provides 200 hours of operation, compliant with JIS 006P and IEC BF22 standards. Suitable for process control and equipment diagnostics.

Frequently Asked Questions

Where can I buy the CBM MES05050 electronic thermometer in your region?

3G Electric supplies the CBM MES05050 thermometer with delivery to your location. We handle all customs documentation and logistics. Contact us for pricing and availability to order.

What is the battery life of the CBM MES05050 thermometer?

The CBM MES05050 features an alkaline battery with 200 hours of continuous operation. It complies with JIS 006P and IEC BF22 standards for reliable industrial use.

What sensor type does the CBM MES05050 use?

The CBM MES05050 is equipped with a K-type thermocouple sensor, ideal for process control and equipment diagnostics across food processing and packaging applications in your region.

Used in

Common applications for CBM
Industrial boilers — CBM circulation pumps (mod. CM 30W) and solenoid valves (ELV series) for heating-loop control and pump staging.
Burner systems — CBM oil nozzles (FLU atomizer types), electrodes (ELC 200 mm), and solenoid coils (ELV 230V AC) for combustion ignition and flame supervision.
Plant maintenance and retrofit — CBM cable glands (CLI M25), motor couplings (ACC type D), and small-radius fittings (RAC 90°) for equipment reconfiguration and sensor integration.
Boiler water treatment — CBM chlorine test kits (DET free+combined) for feedwater and circulating-water quality monitoring in closed-loop systems.
Pump and motor assembly — CBM couplings, fittings, and cable glands for assembly and rewinding of industrial motors, circulation pumps, and auxiliary equipment.

CBM Products

3G Electric supplies CBM measurement & detection. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
CBM
CBM
Infrared thermometer 12:1
CBM
CBM
Multimeter DM 23
Type K thermocouple for infrared thermometer
CBM
Type K thermocouple for infrared thermometer
Temperature limiter SafetyM STB/STW
CBM
Temperature limiter SafetyM STB/STW
Type K thermocouple high temperature for infrared thermometer
CBM
Type K thermocouple high temperature for infrared thermometer
CBM
CBM
Type K thermocouple clamp for infrared thermometer

More from CBM

View all CBM parts
CBM
CBM
Infrared thermometer with type K input
CBM
CBM
Multimeter case
CBM
CBM
Continuity tester
CBM
CBM
Phase indicator
CBM
CBM
Automatic TRMS multimeter MM720 (replaces MM2000)
CBM
CBM
Pump for expansion tank
CBM
CBM
Multifunction inflator battery 2500 mAH
CBM
CBM
Automatic multimeter MM420