L03B..
ON/OFF - P.I.D. thermostats with 1 or 2 outputs with
temperature alarm management
For 1- or 2-outlet heating or cooling systems with 1 probe.
61 71
Dimensions (mm)
98
Sensor Pwr. Num Measuring Resolution Probe accuracy Degree of
Supply outputs range protection
°C °C
1 NTC 10K* probe LS130
L03BI1A included 12Vac/dc 1 -40 - 105 0.1(-19.9-99.9), 1 <±0.3°C(-40-100), ±1°C IP40 (back panel)
1 NTC 10K* probe LS130
L03BI2A included 2 -40 - 105 0.1(-19.9-99.9), 1 <±0.3°C(-40-100), ±1°C IP40 (back panel)
1 NTC 10K* probe LS130
L03BM1B included 230V~ 1 -40 - 105 0.1(-19.9-99.9), 1 <±0.3°C(-50-150), ±1°C IP40 (back panel)
1 NTC 10K* probe LS130
L03BM2B included 2 -40 - 105 0.1(-19.9-99.9), 1 <±0.3°C(-50-150), ±1°C IP40 (back panel)
* A PTC1000 (LS120, not included) can also be connected instead of the NTC10K
ELECTRICAL CHARACTERISTICS
Output on single-pole relay in deviation.
Contact rating 16(4)A 240 Va.c. for each output (L03BI1A-L03BI2A).
Contact rating 12(3.6)A 240 Va.c. for each output (L03BM1B-L03BM2B).
Power consumption 3W.
REGULATIONS AND APPROVALS
Compliant with EN60730-1; EN60730-2-9; EN55022 (Class B); EN50082-1.
INSTALLATION
DIN rail mounting.
OPERATION
Type of control: can operate in ON/OFF or PID mode. Temperature alarm management for output 2 (models L03BI2A and L03BM2B
only).).
ON/OFF control: in ON/OFF mode, the output is ON or OFF depending on the input temperature, setpoint (1SP) and hysteresis value
(1HY).
Hysteresis indicates the magnitude of the setpoint temperature deviation to reactivate the output.
PID control: in PID mode the output is ON for a fraction of cycle time 1CT.
The cycle time characterises the dynamics of the system to be controlled and influences the accuracy of the control.
Proportional control.
Integrative proportional control.
10
HEATING ON/OFF CONTROL ON/OFF CONTROL IN COOLING
The heating output switches off when the The heating output switches on when the
temperature is above the setpoint temperature is above the setpoint
TEMPERATURE TEMPERATURE
SP
SP
HY
The output is
ON when the The output is
temperature is OFF when the
below the setpoint temperature
OUTPUT OUTPUT
+ hysteresis is below the
setpoint +
hysteresis
TIME TIME
PROPORTIONAL CONTROL (P) PROPORTIONAL-INTEGRATIVE CONTROL (PI)
IN HEATING IN HEATING
Overshoot
Overshoot
steady-state error
SP SP
TEMPERATURE
TEMPERATURE
proportional band integral control
proportional band
band
process process
temperature temperature
TIME
TIME
PROPORTIONAL-INTEGRATIVE-DERIVATIVE (PID) HEATING CONTROL
Overshoot
L
SP
TEMPERATURE
proportional band
process
temperature
TIME
FEATURES
NTC10k inputs.
Configurable parameters:
cooling or heating function by assigning positive or negative sign to the differential or proportional band respectively;
minimum or maximum setpoint limits;
ON or OFF status of the output in the event of a defective probe;
minimum ON/ OFF time of the output independent of the temperature value
absolute or relative temperature alarms of output 2 (models with two outputs only).
Operating temperature -10 to 50°C.
Degree of frontal protection IP40 if correctly installed on back of panel.
ON/OFF button on the front.
ACCESSORIES
LS130 LT312U
NTC10k probe, Transformer
scale range from -40 to 105°C, 230/12V 50-60Hz 3VA
2 wires
11
L04BM2A
2-output ON/OFF thermostats, wall mounting
For heating or refrigeration systems with 2 outlets and 1 probe.
53 110
75 96
Dimensions (mm)
Sensor Power supply Num Measuring Resolution Probe accuracy Degree of
Out- range protection
puts K
°C °C
1 probe NTC 10K LS130
L04BM2A including 230Vac 2 -40 - 105 0.1 (-19.9-99.9), 1 <±0.3°C(-40-100), ±1°C IP55
LT312U Power transformer, primary 230Vac, secondary 12Vac
* On this model it is also possible to connect a PTC1000 (LS120, not included) instead of the NTC10K.
ELECTRICAL CHARACTERISTICS
Output on single-pole relay in deviation.
Contact rating 8(3)A 240Vac per output.
Power consumption 2W.
REGULATIONS AND APPROVALS
Compliant with EN60730-2-9, EN60730-1, EN55022 (CLASS B), EN50082-1.
12
INSTALLATION
Wall mounting.
OPERATION
Type of control: can operate in ON/OFF or PID mode.
Temperature alarm management for output 2.
ON/OFF control: in ON/OFF mode, the output is ON or OFF depending on the input temperature, setpoint (1SP) and hysteresis value
(1HY).
Hysteresis indicates the magnitude of the setpoint temperature deviation to reactivate the output.
PID control: in PID mode the output is ON for a fraction of cycle time 1CT.
The cycle time characterises the dynamics of the system to be controlled and influences the accuracy of the control.
Proportional control.
Integrative proportional control.
FEATURES
NTC10k inputs.
Configurable parameters:
cooling or heating function by assigning positive or negative sign to the differential or proportional band respectively;
minimum or maximum setpoint limits;
ON or OFF status of the output in the event of a defective probe;
minimum ON/ OFF time of the output independent of the temperature value
absolute or relative temperature alarms of output 2 (models with two outputs only).
Operating temperature -10 to 50°C.
IP55 degree of protection.
ON/OFF button on the front.
L
ACCESSORIES
LS130
NTC10k probe,
scale range from -40 to 105°C,
2 wires.
13