DTekGaz Atex ethanol probe - Gas Detection
DTekGazGas Detection

DTekGaz Atex ethanol probe

DTekGaz SG895 is an ATEX-certified gas detection probe for monitoring explosive and toxic gases in hazardous environments. The catalytic sensor features microprocessor control with auto-calibration and…

SKU 3G-CBM-02053

Also listed as: DTK 18022 · DTK-18022

Brand
DTekGaz
Item
Atex ethanol probe
Category
Gas Detection
UNSPSC
41113117 — Single gas monitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

DTekGaz
model
SG895
features
Microprocessor-controlled, auto-calibration, auto-diagnostics
detection
Explosive and toxic gases
sensor type
Catalytic
certification
ATEX EX II2 GD

Datasheet Content

Sonde de détection gaz Atex EX II2 GD SG895 De l’élégance et du prestige qui ont toujours distingué la DTEKGaz , naît la sonde de détection gaz Certifié ATEX, cette sonde a la prérogative de pouvoir contrôler grâce à des capteurs à technologie Catalytique la présence de gaz explosifs et toxiques (voir tableau à page. 4) Grâce à plus de technologies innovées comme le logiciel de contrôle, la sonde est apte pour des emplois industriels, des emplois civils, station de compression, usines chimiques, depot de gaz naturel et gpl, ateliers, galeries, distributeurs de carburants, raffineries et garages. La sonde est gérée par un microprocesseur qu’en plus de fournir un signal d’alarme à l’unité de contrôle à laquelle elle est reliée, elle est capable de se faire un auto diagnostic et donc un ETALONNAGE AUTOMATIQUE de manière à avoir constamment la plus grande précision de détection. Le réglage automatique permet au détecteur de s’adapter dans les milieux difficiles et à température variable, en évitant des fausses alarmes dues à des évènements anomaux. La sonde est dotée d’une sortie linéaire de 4 à 20 mA et donc elle peut être connectée à une unité de contrôle de type industriel de la DTEKGaz Instrument indispensable pour le contrôle annuel des sondes Instrument d’Essai T S 1 0 0 7 Pour pouvoir faciliter la lecture des paramètres fonctionnels de la sonde ainsi que le contrôle de fonctionnement annuel conseillé par la DTEKGaz, il a été construit le Tester portable TS1007. Le tester permet de lire toutes les données qui se trouvent dans la mémoire des sondes et grace à la transmission série il est possible imprimer le rapport de contrôle qui confime les données testées. Manuel NORMES MARQUAGE Version de sécurité anti-déflagrant d’utilisation BEINAT S.r.l d’installation EN 60079-0 0477 II2GD EN 60079-1 d’entretien Ex d IIC T6 (85°C) EN 61241-0 EN 61241-1 Ex tD A21 IP66 85° C EN 50270 EUM1 10 ATEX 0169 Ne pas ouvrir sous tension Attendre 60 secondes avant l’ouverture N° matricule: voir la déclration de Firmware Version 0.0 conformité jointe. Nota Importante. Prima di Utilizzare, Leggere attentamente Le Istruzioni Di Uso e Manutenzione Le presenti istruzioni devono essere lette e comprese da tutte le persone incaricate all’uso ed alla manutenzione ed alle riparazione dell’impianto innerente alla rilevazione di Gas. Avant de connecter l'appareil il faut lire attentivement le manuel d'instructions e conservarlo per le future consultazioni. Il est conseillé de faire ces interventions par un personnel autorisé et / ou spécialisé en conformité avec les recommandations de la DTEKGaz Précautions S’ASSURER de l’intégrité de la sonde après l’avoir retirée de sa confection. Vérifiez que les descriptions sur le produit soient correspondantes au type de gaz utilisé et à la tension requise LIMITES DE RESPONSABILITÉ * Tous usages divers de la sonde pour laquelle elle a été conçue sont considérés non conformes soit à l’installation que la conservation de la sonde. Les usages non conformes signifient tous usages différents de ceux qui sont mentionnés dans le manuel d’utilisation et du non respect des normes en vigueur. DTEKGaz décline toute responsabilité pour tous les dommages causés aux personnes, aux animaux et objets y compris les blessures, la mort des personnes et / ou des utilisateurs * DTEKGaz ne prend pas en charge ni autorise aucune entreprise, personne ou entité à assumer la responsabilité envers elle, même si elles sont engagées dans la vente de ses produits. * Dans le cas de choix du produit non approprié pour superviser l’installation de gaz, la DTEKGaz n’est pas responsable de tous les dommages directs ou indirects causés par ce fait et elle ne sera pas tenu de verser aucune indemnité. À MOINS QUE CE PRODUIT N’AIT PAS ÉTÉ DEFINI ET CHOISI PAR LA DTEKGaz POUR UTILISATION REQUISE. INSTALLATION Il est A S B S O L U M E N T I N T E R D I T de trouer le boîtier anti-déflagrant au risque de la perte du degré de protection et donc il ne sera plus à norme. M O D A L I T É S D E C E S S I O N S: l’installation de la sonde S G 8 9 5, son entretien ordinaire et extraordinaire, la mise au rebut à la fin de son cycle de vie garantie par le constructeur doivent être effectués par un personnel autorisé et spécialisé Ne pas le baigner . La sonde n’est pas imperméable et il faut se rappeler qu’elle a un degré de protection I P 6 6 / 6 7 Ne pas le laissez tomber. Les forts coups ou des chutes pendant le transport ou l’installation peuvent endommager l’appareil. Évitez des brusques baisses de température. Les variations soudaines de température peuvent provoquer la formation de condense et la sonde pourrait ne pas bien fonctionner . Nettoyage. Ne nettoyer l’appareil avec des produits chimiques. Si nécessaire utilisez un chiffon mouillé d’eau. Ne jamais approcher un chiffon imbibé de diluant à peinture, d'alcool, de détergents et de produits chimiques. Caractéristiques Techniques Alimentation ........................................................................................................... 12÷24 VDC ± 10% Absorption ...................................................................90 mA en fonction, 110 mA en alarme Max @ 13,8V Capteur de détection ............................................................................... Catalytique,cellule électrochimique Plage de travail de l’élément sensible référé au gaz explosif....................................................100% des LIE Plage de travail de l’élément sensible référé au gaz toxique.................................................................1000ppm Plage de mesure détection selon le type de gaz ......................................................... Voir tableau page 4 Précision de la sonde ................................................................................................................. 1% FS Dérivé à long terme en air propre ................................................................................... < 3% des L.I.E. Temps de réponse ............................................................................................................... < 10 secondes Procédure d’auto zéro ................................................................. Compris dans les algorithmes du logiciel Temps de préchauffage (warm-up time) ..................................................................................... 4 minutes Signal de sortie analogique ........................................................................... 4 ÷20 mA tolérance de série Température de fonctionnement pour gaz explosifs ........................................................de -20°C à +60°C Température de fonctionnement pour gaz toxiques ....................................................... de -20°C à +50°C Température de stockage .......................................................................................... de -25°C à +70°C Unités de contrôle compatibles ...... BX444-M, BX449F, GS100M, BX180, BX280, BX150, GS300M, BX3,BX30816 Distance max. entre la sonde et l’unité de contrôle......................................................................... 100 m Diamètre de câbles de branchement de la sonde ............................................................................. 1 mm Connexion : les câbles de connexion de la sonde ne doivent pas être posées ensemble avec ceux de la puissance Si on pose ensemble les câbles de connexion et ceux de puissance, il faut utiliser un câble blindé. Compatibilité Électromagnétique Norme de référence ................................................................ EN 50270 Boîtier ................................................................................................................................ Antidéflagrant Boîtier ............................................... ..................................................................................... Aluminium Dimension (diamètre du boîtier) ............................................................................................... 100 mm Degré de protection ............... .................................................................................................IP66/67 Carte expansion relais CARD03 (en option) à Greffe rapide Page 2 Détails Particuliers pour l’emploi en Atmosphère Explosive conformément à la Directive Européenne ATEX 94/9/CE. Les sondes SG895 de la DTEKGaz sont conformes aux dispositions de la Directive Européenne ATEX 94/9/CE relative aux atmosphères explosives. Les sondes étant des dispositifs de sécurité conformément à la directive ATEX 94/9/CE, elles ne peuvent pas être utilisées pour la mesure des gaz explosifs. Les informations rapportées dans les paragraphes suivants doivent être prises en considération et respectées par le responsable des lieux de l’installation du matériel. Faire référence à la Directive Européenne ATEX 1999/92/CE relative à l’amélioration de la protection en matière de sécurité et de santé des travailleurs exposés aux risques des atmosphères explosives. Spécifications pour les installations mécaniques et électriques dans la zone classée ATEX. L'installation doit être effectuée conformément aux normes en vigueur, notamment les normes: EN 60079-1, EN 60079-, EN 61241-0, EN 61241-1 Sondes antidéflagrants (d) - Ces appareils ont été spécialement conçus pour les industries de superficie II, Catégorie 2, zone 1 et 2 (Gaz) et pour zone 21 ou 22 (Poussières). - Les appareils doivent être équipés d'une entrée de câbles ATEX avec le marquage Ex d IIC - Les températures des lieux d’utilisation sont comprises entre - 10°C et + 60°C dans la classe de température T6. - Les câbles doivent être protégés mécaniquement. - Le corps du capteur sera connecté à la borne de masse interne ou externe qui doit être protégé contre la corrosion.. - L'utilisateur doit régulièrement nettoyer le matériel afin d'éviter les dépôts de poussières. - Les sondes doivent être installées mécaniquement de telle sorte que la cellule de détection soit orientée vers le bas. - Si les connexions sont situés dans une zone classée ATEX, elles doivent être effectués en boîtier de type certifié. Dimensions Vue arrière Vue latérale 100 mm M 5x1,5 65 mm Vi s 77 de m m 100 mm fix at io n 37 mm 123456789012345 123456789012345 123456789012345 Filetage 3/4 gaz 123456789012345 123456789012345…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DTekGaz Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

DTekGaz SG895 is an ATEX-certified gas detection probe for monitoring explosive and toxic gases in hazardous environments. The catalytic sensor features microprocessor control with auto-calibration and auto-diagnostic capabilities, meeting EX II2 GD standards for industrial safety applications.

Frequently Asked Questions

Where can I buy the DTekGaz SG895 ATEX ethanol probe worldwide?

3G Electric is an authorized distributor of DTekGaz gas detection equipment. We handle worldwide delivery, logistics, and customs clearance for the SG895 ATEX ethanol probe. Contact us for lead times and quotations on hazardous area monitoring solutions.

What is the lead time for the DTekGaz SG895 probe?

Lead time for the DTekGaz SG895 ATEX ethanol probe varies by region and stock availability. 3G Electric coordinates delivery worldwide and manages all logistics. Request a quote for your specific location and delivery schedule.

Is the DTekGaz SG895 certified for explosive gas environments?

Yes. The DTekGaz SG895 is ATEX EX II2 GD certified for use in explosive and toxic gas hazardous areas. The catalytic sensor features microprocessor-controlled auto-calibration and auto-diagnostics for reliable industrial safety compliance.

Used in

Common applications for DTekGaz
Petrochemical plants — DTekGaz ATEX SG895 catalytic sensor probes monitor explosive gas concentrations in confined tanks and process vessels
Refrigeration and HVAC maintenance — DTekGaz HCF100 semiconductor probe detects R407C, R410A, and R32 leaks during service and commissioning
Industrial hazardous areas — DTekGaz extension card relay outputs interface with plant PLC/DCS systems to trigger alarms and emergency shutdowns
Portable field detection — DTekGaz 12 V rechargeable battery and metal-housed hydrogen/butane probes support temporary site surveys and confined-space entry
Fixed control room installations — DTekGaz 24 VDC audible alarm and extension modules provide centralized monitoring of multiple distributed sensor probes
Water treatment and biogas plants — DTekGaz catalytic and semiconductor probes detect methane, hydrogen sulfide, and other hazardous gas byproducts

DTekGaz Products

3G Electric supplies DTekGaz gas detection. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Atex methanol probe
DTekGaz
Atex methanol probe
Atex acetone probe
DTekGaz
Atex acetone probe
Atex hydrogen probe
DTekGaz
Atex hydrogen probe
DTekGaz
DTekGaz
Atex probe NG
Atex white spirit probe
DTekGaz
Atex white spirit probe
DTekGaz
DTekGaz
Atex CO2 probe

More from DTekGaz

View all DTekGaz parts
"Natural Gas Detection Test Kit" case (with TS1008+printer)
DTekGaz
"Natural Gas Detection Test Kit" case (with TS1008+printer)
DTekGaz
DTekGaz
R134A gas probe
DTekGaz
DTekGaz
Battery 12V - 2.2Ah
DTekGaz
DTekGaz
CO2 probe metal housing IP66
DTekGaz
DTekGaz
Probe for R32 gas
DTekGaz
DTekGaz
Probe for R404 gas
DTekGaz
DTekGaz
Central detection box DIN rail small IP 65
DTekGaz
DTekGaz
Valve for 1liter bottle