We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

DTekGaz Detection center 16 probes - Gas Detection
DTekGazGas Detection

DTekGaz Detection center 16 probes

DTekGaz detection center accommodates 16 conventional probes for multi-point gas monitoring across industrial facilities. Features pre-alarm thresholds from 5–9% LEL and general alarms at 10–50% LEL, with probe…

SKU 3G-CBM-02005

Also listed as: DTK 08008 · DTK-08008

Brand
DTekGaz
Item
Detection center 16 probes
Category
Gas Detection
UNSPSC
41113117 — Single gas monitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

DTekGaz
probe capacity
16 conventional probes
pre alarm range
5% to 9% LEL or 75 to 135 ppm
oxygen alarm low
<18.5%
oxygen alarm high
>23.5%
probe distance max
100 m
datalogger capacity
50 episodes
general alarm range
10% to 50% LEL or 150 to 300 ppm
operating temperature
-10°C to +60°C

Datasheet Content

Centrale gaz 1 - 16 sondes conventionnelles BX316xp Rev. 4 Avec programme d'entretien CARACTÉRISTIQUES PRINCIPAUX > Mot de passe pour accéder aux fonctions > Datalogger stocke 50 épisodes. > Programme d'entretien ordinaire. > Signalisation source d'alarmes. > Lecture automatique du type de gaz > Niveau de pré-alarme réglable pour chaque sonde. > Niveau d'alarme réglable pour chaque sonde. > Possibilité de diviser les zones max. 2 > Vérification de défaut de toutes les sondes Les années d'expérience dans l'industrie et la > Fonction de sécurité positive connaissance du marché combiné avec le prestige > Plage de fonctionnement de 20 à 100% qui a toujours distingué DTEKGaz, ont permis > Possibilité d'insérer 1 carte d'extension de relais la création d'une nouvelle Unité de contrôle de > Réinitialisation d'usine > Connexion d'une imprimante gaz; la BX316xp qui a la prérogative de pouvoir > Connexion du bouton d'alarme manuelle contrôler, par les sondes qui y sont connectés, la > Affichage de: présence de gaz; - Nom de marque Toxiques, Explosifs, et Oxygène - Numéro de série Les sondes conventionnelles - Date et heure On peut connecter de façon conventionnelle 16 - Sondes sous surveillance sondes, 8 par zone de 4 à 20 mA. - Graphique de gaz détecté La concentration de gaz détectée par chaque sonde à rotation est affichée. La centrale a deux niveaux de danger qui sont: I NIVEAU, pré-alarme. Cette donnée est variable. Le niveau est sélectionnable de 5% à 9% de la L.I.E. ou de 75 à 135 ppm II NIVEAU, alarme générale. Cette donnée aussi est variable de 10% à 50% de la LIE pour le gaz explosif et de 150 à 300 ppm pour le Gas Tox ic. La centrale a deux relais d'alarme générale avec ou sans la sécurité positive, afin qu'ils puissent également contrôler aussi deux électrovannes séparément. Enfin, la centrale peut contrôler le fonctionnement éffectif des sondes liées. ALARME OXYGÈNE pour <carence (en oxygène à 18,5%) et >excès (en oxygène à 23,5) Cartes d'extension CARTD-RLS4 Carte relais: chaque carte a 4 relais et on peut connecter jusqu'à 16 cartes CARD-BMS16 Convertisseur courant-tension Important: Les opérations de montage/entretien de l'appareil doivent être effectuées par un personnel qualifié conformément aux lois et les normes en vigueur. Le constructeur n'assume aucune responsabilité quant à l'utilisation des produits qui doivent se conformer aux normes environnementales. Note importante Avant de brancher l'appareil, il est recommandé de lire attentivement la notice technique et de la conserver pour une utilisation ultérieure. Il est également recommandé d'effectuer correctement les branchements électriques selon les schémas inclus en respectant les consignes de sécurité et les normes. N.B. Consulter la notice technique dans tous les cas où le symbole à côté est présent CONFORMITÉ  Notice technique I N S TA LLE R EN ZON E EN 45544-1-3 EN 50270 EN 61010-1 Conforme EN 60079-29-1-2 installation/emploi SÉCURISÉE NO ATEX Rapports délivrés par TUV Italia Guide branchement électrique aussi sur Chaine: Beinat gas solutions Caractéristiques principales Mot de passe: Pour accéder au menu des paramètres Configurer: La date et l’heure Sélectionner: Le sondes activation/désactivation Sélectionner: Le type de gaz à détecter: (toxique, explosif, oxygène) Configurer: Le niveau de pré-alarme pour chaque sonde de 3% à 9% de la LIE Configurer: Le niveau de l’alarme pour chaque sonde de 10% à 50% de la LIE Sélectionner: Nombre de zones, 1 ou 2, divisible avec 8 sondes par zone Sélectionner: Le fonctionnement du relais en impulsions ou en continu BX316xp Sélectionner: La Plage de travail des sondes de 0-20% ou de 0-100 de la L.I.E Sélectionner: La fonction de la sécurité positive Sélectionner: La plage de fonctionnement: 20 ou 100% de la L.I.E. Configurer: La fonction de la mémorisation de l’alarme (réservée aux gaz toxiques) Configurer: L'activation/désactivation de la sirène externe. Configurer: L'activation/désactivation du buzzer interne. Lire: Les événements d’alarme (data logger), jusqu’à un max. de 50 épisodes. Connexion: D'une imprimante portable via le port USB; Quadro di Carte d'extension de relais; Convertisseur courant-tension cortesia ECRAN LCD en état de fonctionnement normal Affichage : marque et numéro de série Affichage : date et heure Affichage : sonde sous surveillance Affichage : automatique du gaz explosif L.I.E ou du gaz toxique ppm Affichage : graphique de la quantité de gaz détecté Affichage : le count-down (compte à rebours) en fase du Warm up (chauffage) Panneau Frontale Boutons de navigation, bouton de test pour vérifier le fonctionnement de la centrale et bouton de reset pour réinitialiser les mémoires d'alarme. Led d'affichage de sirène externe silencieuse; Pour ce faire, entrer le mot de passe Led de service (voir page 3) Led de visualisation de l’état de charge de la Batterie tampon. Caractéristiques Techniques Alimentation Primaire VERSION RAIL DIN ...................................................................... 12/15 VDC ± 10% Alimentation secondaire PAR BATTERIE Max 2.2 Ah (non fornie) ............................................... 12,7 VDC ± 10% Charge Batterie Max 2,2 Ah ................................................................................................ controllata Consommation avec alimentation 15 VDC ............................................ ...................... 25W Max @ 15 VDC Capacité des contacts sur relais.......................................................................................10A 250V resistivi ALARMES Pré Alarme réglable pour chaque sonde de ..................................... 5% à 9% de la LIE avec un pas de 1% Alarme générale, réglable pour chaque sonde .. de 10% à 20% LIE avec pas de 1% (par défaut 20% LIE) N.B. EN SAISISSANT LE MOT DE PASSE (PUK) il est possible de régler cette alarme de 10% à 50%, avec un pas 5% Alarme OXYGENE .......................... <Carence oxygène,> Excès oxygène .............................. voir page 12 VOYANTS Voyants: ..............................réseau connecté, alarmes, fonction batterie, surcharge sonde e batterie, défaut Voyant d’alarme manuelle ............................................................................................... affiché (BTN) Voyant de la sirène activée ................................................................................... Indiqué par LED rouge Durée de la phase du préchauffage grace au count-down..................................................... 90 secondes Test manuel ........................................................................................................................... incorporé Exclusion de la sirène externe et du vibreur interne ................................................................... via logiciel ZONES D'ALARME ET SONDES Nombre de zones ............................................... ..................................................................... max. 2 Nombre de sondes connectables ..................................................................................................... 16 Inclusion/exclusion des sondes ....................................................................................... par menu approprié Sondes compatibles ..... Semi-conducteur, catalytique, cellule électrochimique, Pellistor, fluorescence optique Pannes détectées par le circuit de défaut ........................................ Interruption, court circuit ou décadence Signal d’entrée ................................................................................................ 4 ÷ 20 mA sur 150 Ohm Plage de fonctionnement uniquement pour gaz explosifs .......................................... 0-20% ou 0-100 del LIE Actualisation des données ............................................................................................. ............... 2 ms Précision de l’appareil............................................................................................................... 1% FS CONNECTIONS Imprimante ...................................................................................................................... Via USB port CARD-RLS4 carte d'extension de relais ...........................................................Chaque carte inclut 4 rélais CARD-BMS16 convertisseur tension-courant ............................... chaque carte connecte jusqu'à 16 sondes INFORMATIONS GÉNÉRALES Température de fonctionnement ................................................................................... -10°C ÷ + 60°C Distance entre les sondes et la centrale ........................................................................................ 100 m Distance max entre la batterie et la centrale .................................................................................. 0,5 m Diamètre des câbles de branchement aux sondes .......................................................................... 1 mm2 Connexion: les câbles de connexion de la sonde ne doivent pas être posées ensemble avec ceux de la puissance. SI ON POSE ENSEMBLE LES CÂBLES DE CONNEXION ET CEUX DE LA PUISSANCE, IL FAUT UTILISER UN CÂBLE BLINDÉ. BX316xp - Dimensions rail DIN/Oméga EN 50092 9 modules .............................................. 158x90x58 mm Degré de protection ............................................................................................................ en air IP20 Boîte en option pour BX316xp, Degré de protection: IP65 composition: a) Rail DIN/Oméga pour…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DTekGaz Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

DTekGaz detection center accommodates 16 conventional probes for multi-point gas monitoring across industrial facilities. Features pre-alarm thresholds from 5–9% LEL and general alarms at 10–50% LEL, with probe coverage extending to 100 m. Operates reliably from −10°C to +60°C for demanding safety applications.

Frequently Asked Questions

Where can I buy the DTekGaz DTK08008 detection center worldwide?

3G Electric is an authorised DTekGaz distributor offering worldwide delivery. We handle logistics, customs clearance, and supply chain coordination for the DTK08008 16-probe detection center to industrial facilities globally. Lead time on request.

What is the lead time and delivery schedule for the DTK08008?

Lead time varies by region and inventory availability. 3G Electric manages sourcing and logistics for worldwide delivery of the DTK08008. Contact us for a custom quote and estimated delivery timeframe based on your location and order volume.

What is the maximum probe distance for the DTekGaz DTK08008 detection center?

The DTK08008 supports up to 16 conventional probes with maximum coverage extending to 100 m per probe run. Operating range is −10°C to +60°C, with pre-alarm thresholds at 5–9% LEL and general alarm at 10–50% LEL for reliable multi-point gas monitoring.

Used in

Common applications for DTekGaz
Petrochemical plants — DTekGaz ATEX SG895 catalytic sensor probes monitor explosive gas concentrations in confined tanks and process vessels
Refrigeration and HVAC maintenance — DTekGaz HCF100 semiconductor probe detects R407C, R410A, and R32 leaks during service and commissioning
Industrial hazardous areas — DTekGaz extension card relay outputs interface with plant PLC/DCS systems to trigger alarms and emergency shutdowns
Portable field detection — DTekGaz 12 V rechargeable battery and metal-housed hydrogen/butane probes support temporary site surveys and confined-space entry
Fixed control room installations — DTekGaz 24 VDC audible alarm and extension modules provide centralized monitoring of multiple distributed sensor probes
Water treatment and biogas plants — DTekGaz catalytic and semiconductor probes detect methane, hydrogen sulfide, and other hazardous gas byproducts

DTekGaz Products

3G Electric supplies DTekGaz gas detection. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Detection unit 3 probes
DTekGaz
Detection unit 3 probes
Detection unit 4 probes
DTekGaz
Detection unit 4 probes
DTekGaz
DTekGaz
Gas detection center Din rail 8 probes - 12V
DTekGaz
DTekGaz
Gas detection center Din rail 4 probes
Detection unit 1 probe
DTekGaz
Detection unit 1 probe
DTekGaz
DTekGaz
Gas detection central rail DIN 16 probes - 12V

More from DTekGaz

View all DTekGaz parts
"Natural Gas Detection Test Kit" case (with TS1008+printer)
DTekGaz
"Natural Gas Detection Test Kit" case (with TS1008+printer)
DTekGaz
DTekGaz
R134A gas probe
DTekGaz
DTekGaz
Battery 12V - 2.2Ah
DTekGaz
DTekGaz
CO2 probe metal housing IP66
DTekGaz
DTekGaz
Probe for R32 gas
DTekGaz
DTekGaz
Probe for R404 gas
DTekGaz
DTekGaz
Central detection box DIN rail small IP 65
DTekGaz
DTekGaz
Valve for 1liter bottle