We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Image not available
DTekGazGas Detection

DTekGaz Probe for gas R407

DTekGaz HCF100 is a gas detection probe for refrigerant gases including R407C, R410A, and R32, featuring IP55 rating and semi-conductor sensing technology. Measurement range reaches 999 ppm with automatic…

SKU 3G-CBM-02038

Also listed as: DTK 16006 · DTK-16006

Brand
DTekGaz
Item
Probe for gas R407
Category
Gas Detection
UNSPSC
41113117 — Single gas monitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

DTekGaz
model
HCF100
ip rating
IP55
calibration
automatic
sensor type
semi-conductor
detection gases
R134a, R404A, R407C, R410A, R32, 507
housing material
self-extinguishing polypropylene VDE 0471
measurement range
999 ppm
temperature range
-20 to +60°C

Datasheet Content

Sonde conventionnelle de détection gaz HCF100 V. 4 DTK16002/16004/16006/16008/16010 Réfrigérant FREON R134a, R404A, R407C, R410, R32, 507 La nouvelle HCF100 est née de l'élégance et du prestige qui ont toujours distingué la DTEKGaz et du concept de home fitness La sonde HCF100 est une unité de détection de gaz à technologia semi-conducteur avec degré de protection IP55 qui, associée à l'une de nos centrales de type industriel permet de détecter les gaz toxiques tels que le Réfrigérant FREON R134a, R404A, R407C, R410A, R32, 507. La sonde est gérée par un microprocesseur que en plus de fournir un signal d’alarme à la centrale à laquelle elle est reliée, elle est capable de faire un auto diagnostic et donc un ETALONNAGE AUTOMATIQUE de manière à avoir constamment la plus grande précision de détection. L’étalonnage automatique permet à la sonde de s’adapter aux environnements difficiles et à des températures variables en évitant ainsi des fausses alarmes dues à des évènements anomaux. La sonde est dotée d’une sortie linéaires 0 ÷s 999 ppms et conforme au standard 4 ÷s 20mA. Instrument indispensable pour le contrôle annuel des sondes Instrument d’Essai TS1008 Pour faciliter la lecture des paramètres fonctionnels de la sonde ainsi que le contrôle de fonctionnement annuel conseillés par la DTEKGaz, il a été conçu le Tester portable TS1008. Le tester permet de lire toutes les données qui se trouvent dans la mémoire des sondes et grace à la transmission en série il est possible imprimer le rapport de contrôle des données. Important: Les opérations de montage/entretien de l'appareil doivent être effectuées par un personnel qualifié conformément aux lois et les normes en vigueur. Le constructeur n'assume aucune responsabilité quant à l'utilisation des produits qui doivent se conformer aux normes environnementales. Note importante Avant de brancher l'appareil, il est recommandé de lire attentivement la notice technique et de la conserver pour une utilisation ultérieure. Il est également recommandé d'effectuer correctement les branchements électriques selon les schémas inclus en respectant les consignes de sécurité et les normes. N.B. Consulter la notice technique dans tous les cas où le symbole à côté est présent CONFORMITÉ Notice technique EN 50194 EN 50270 Conforme EN 60079-29-1 installation/emploi Installation EN 60079-29-2 Guide connexion électrique aussi sur Précautions S’assurer de l’intégrité de la sonde après l’avoir retirée de sa confection. Vérifiez que les descriptions sur la boîte soient correspondantes au type de gaz et de la tension électrique utilisée. Suivre attentivement le schéma lorsqu’on effectue le branchement électrique. Nous déclinons toute responsabilité pour des dommages causés à des personnes, animaux ou choses pour n’importe quel usage inapproprié pour laquelle la sonde a été projetée. Termes et Fiabilité: l’installation de la sonde, son entretien ordinaire et extraordinaire qui doivent s’effectuer une (1) fois par an et la mise au rebut à la fin de la période de fonctionnement garantie par le constructeur ne doivent être effectués que par un personnel autorisé et spécialisé. Installation: Il est absolument interdit de trouer le boitier de la sonde au risque de la perte du degré de protection. Ne pas mettre en contact avec de l’eau. La sonde n’est pas imperméable et elle ne doit pas entrer en contact avec de l’eau en se rappelant que le degré de protection IP55 Ne pas faire tomber. Des forts coups ou des chutes pendant le transport ou l’installation peuvent endommager l’appareil. Évitez des brusques baisses de température. Des brusques variations de température peuvent provoquer la formation de condense et la centrale pourrait ne pas bien fonctionner. Nettoyage. Ne jamais nettoyer l’appareil avec des produits chimiques, des diluants, alcool et détergents. Si nécessaire utilisez un chiffon humide. Caractéristiques Techniques Alimentation ......................................................................................................... 12÷24 VDC ± 10% Absorption ...............................................................90 mA en fonction, 110 mA en alarme Max @ 13,8VDC signaux Leds......................................................................... Vert: régulier, Jaune: défaut, Rouge: alarme Relais d'alarme / Défaut ...................................................................................... 5A SELV 30 VDC Capteur................................................................................................................... Semi-conducteur Détection............................................................................................................................... FREON Seuil d'alarme:.............................................................................................. Linéaire de 0 à 300 ppm Plage de mesure ........................................................................................................... 0 ÷ 999 ppm Signal de sortie analogique .........................................................4 ÷ 20 mA sur 220 Ohm tolérance de série Prise de test USB ................................................................................................................... TS1008 Précision du détecteur .................................................................................................... +/1 % FS Dérive à long terme en air propre ...................................................................................... < + 3% LIE Procédure d’auto zéro ................................................................. Compris dans les algorithmes du logiciel Temps de réponse .......................................................................................................................< 10” Temps d’attente .....................................................................................................................1 minute Contrôle de la température ambiante ............................................................compensé par micro processeur Humidité de fonctionnement ........................................................................................ 0-90% non condensée Température de fonctionnement ................................................................................. de -10°C à + 60°C Centrales compatibles ....BX150, BX180, BX280, BX444-Mc, BX449F, GS100M, GS300M, GS300-Mc, BX308xp, BX316xp Distance max. entre la sonde et la centrale ................................................................................... 100 m Diamètre de câbles de branchement de la sonde ........................................................................... 1 mm2 Connexion: les câbles de connexion de la sonde ne doivent pas être posées ensemble avec ceux de la puissance. Si on pose ensemble les câbles de connexion et ceux de puissance, il faut utiliser un câble blindé. Boitier de la sonde ...................................................................... Polipropilene autoestinguente VDE 0471 Degré de protection ....................................................................................................................... IP55 Dimension du boîtier ..................................................................................................... 78x114x58 mm Caractéristiques techniques HCF100 Code Type de Gaz Capteur Plage de mesure Température HCF100fre1 Freon R134a Semi-conducteur 999 ppm -20+60°C HCF100fre2 Freon R404A Semi-conducteur 999 ppm -20+60°C HCF100fre3 Freon R407C Semi-conducteur 999 ppm -20+60°C HCF100fre4 Freon R410A Semi-conducteur 999 ppm -20+60°C HCF100fre5 Freon R32 Semi-conducteur 999 ppm -20+60°C HCF100fre6 Freon 507 Semi-conducteur 999 ppm -20+60°C HCF100fre5 Freon R32 Semi-conducteur 999 ppm -20+60°C HCF100fre6 Freon R507 Semi-conducteur 999 ppm -20+60°C ATTENTION ! Le capteur semi-conducteur a une durée qui peut varier de 5 à 6 ans. (en air propre) La température de fonctionnement de - 10°C à + 60°C. Chaque bouffée instantanée de gaz au-delà de 100% de la L.I.E réduit la durée de vie du capteur. Faire l’essai du détecteur en simulant une fuite de gaz en émettant du gaz par un pulvérisateur précalibré. Remarque Le test de fonctionnement et l'éventuel étalonnage doivent être effectués au moins une fois par an par un professionnel qualifié. Page 2 Centrales compatibiles CENTRALE FIXATION SONDES Max. DEGRÉ PRÉ ALARMES SÉCURITÉ PLAGE Protect. Alarmes Positive de mesure GS100M centrale 1 zone Mur/tableau 1 IP44 2 1 OUI NON GS300M centrale 1 zone Mur/tableau 3 IP44 2 1 OUI NON BX444-MC centrale 1 zone Mur/tableau 4 IP44 2 1 OUI NON BX150 centrale 1 zone Au panneau 1 IP42 1 1 OUI NON BX180 centrale 1 zone Rail Din Omega 1 IP20 1 1 OUI NON BX280 centrale 1 zone Rail Din Omega 2 IP20 1 1 OUI NON BX449F centrale 1 zone Rail Din Omega 4 IP20 1 1 OUI NON BX308 centrale 1 zone Rail Din Omega 8 IP20 1 1 OUI OUI BX308/Box centrale 1 zone Au mur 8 IP65 1 1 OUI OUI BX316 centrale 2 zones Rail Din Omega 16 IP20 1 2 OUI OUI BX316/Box centrale 2 zones Au mur 16 IP65 1 2 OUI OUI TAKITJ8 * Centralisateur Au mur 8 IP65 - - - - ENTRETIEN •L'utilisateur périodiquement (tous les 6 mois), doit procéder à une vérification du fonctionnement du détecteur en pulvérisant du gaz de test dans les fentes frontales jusqu'à déclencher l'alarme. • Au moins une fois par an, faire un contrôle plus précis…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DTekGaz Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

DTekGaz HCF100 is a gas detection probe for refrigerant gases including R407C, R410A, and R32, featuring IP55 rating and semi-conductor sensing technology. Measurement range reaches 999 ppm with automatic calibration. Operates from −20 to +60°C in HVAC and refrigeration systems.

Frequently Asked Questions

Where can I buy the DTekGaz HCF100 gas detection probe?

Order the DTekGaz HCF100 through 3G Electric, an authorised distributor. We handle worldwide delivery, customs clearance, and logistics. Lead time on request — contact our procurement team for availability and quotation.

What is the lead time and shipping process for this gas detection probe?

Lead time varies by destination and current supply. 3G Electric manages global logistics for all orders. We arrange customs handling and delivery to your facility worldwide. Request a quote for specific lead-time details.

Which refrigerant gases does the DTekGaz HCF100 detect?

The HCF100 detects R134a, R404A, R407C, R410A, R32, and 507 refrigerant gases. It features a 999 ppm measurement range with automatic calibration, IP55 housing, and semi-conductor sensing technology for HVAC and refrigeration systems.

Used in

Common applications for DTekGaz
Petrochemical plants — DTekGaz ATEX SG895 catalytic sensor probes monitor explosive gas concentrations in confined tanks and process vessels
Refrigeration and HVAC maintenance — DTekGaz HCF100 semiconductor probe detects R407C, R410A, and R32 leaks during service and commissioning
Industrial hazardous areas — DTekGaz extension card relay outputs interface with plant PLC/DCS systems to trigger alarms and emergency shutdowns
Portable field detection — DTekGaz 12 V rechargeable battery and metal-housed hydrogen/butane probes support temporary site surveys and confined-space entry
Fixed control room installations — DTekGaz 24 VDC audible alarm and extension modules provide centralized monitoring of multiple distributed sensor probes
Water treatment and biogas plants — DTekGaz catalytic and semiconductor probes detect methane, hydrogen sulfide, and other hazardous gas byproducts

DTekGaz Products

3G Electric supplies DTekGaz gas detection. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Probe for gas R410
DTekGaz
Probe for gas R410
DTekGaz
DTekGaz
Probe for R513A gas
DTekGaz
DTekGaz
Probe for R290 gas
Probe tester
DTekGaz
Probe tester
3S hydrogen probe
DTekGaz
3S hydrogen probe
DTekGaz
DTekGaz
3S GN Probe

More from DTekGaz

View all DTekGaz parts
"Natural Gas Detection Test Kit" case (with TS1008+printer)
DTekGaz
"Natural Gas Detection Test Kit" case (with TS1008+printer)
DTekGaz
DTekGaz
R134A gas probe
DTekGaz
DTekGaz
Battery 12V - 2.2Ah
DTekGaz
DTekGaz
CO2 probe metal housing IP66
DTekGaz
DTekGaz
Probe for R32 gas
DTekGaz
DTekGaz
Probe for R404 gas
DTekGaz
DTekGaz
Central detection box DIN rail small IP 65
DTekGaz
DTekGaz
Valve for 1liter bottle