Datasheet Content
TYPE B
Regulators
DOMESTIC GAS REGULATORS
TYPE B Regulators
Domestic gas regulators
e APPLICATIONS
Residential
houses
810
825 8CH 30
840
86
810
Commercial utilities,
Municipal buildings
810
825
840
8CH 30 850 8CH 60
lndustrial
8 75 8CH 90
appliances
8100 8CH 120
The type B regulators provide
economical pressure reducing contrai in
a variety of residential, commercial and Use of 2, 3 or 4 regulators
industrial applications. The regulator can be used mounted parallel (battery)
for a variety of gaseous fluids. lt will be utilized in a
distribution network, with inlet pressure varying from 5 to
0, 1 bar. The outlet pressure can be set between 9 and 400
mbar, with a flow capacity of O to 48 m3/h. The regulator can
be installed in pressure reducing cabinets or reducing and
metering cabinets in a compact design above ground or in
underground modules.
TYPE B Regulators
Domestic gas regulators
e DESCRIPTION OPTIONS
• The type B regulator is a direct acting spring /oaded • ln/et and out/et connections adaptable on demand.
regulator, with high performance and safety features. • Law in/et pressure possibilities (O. 1 to 0.5 bar).
• 2 stages of reduction produce a constant out/et pres· • Option for different out/et pressure settings (standard and
sure, which is insensitive to changes in in/et pressure. The specific).
regulator is factory pre-set. • Options for manua/ pressure setting.
• The slam shut cuts the flow in case of excessive f/ow or • Factory pre-set relief valve.
when the out/et pressure drop be/ow set point (high gas • Vent connectable to the exterior.
demand or broken line), or in case the in/et pressure drop • Vent connection adaptable on demand.
below the set point (network pressure drops or pipe • Underground modules are supplied with corrosion protec
damage). A manua/ reset allows for restarting the regulator tion.
after clearing failure. • Option for parai/el mounting of regulators to forma "battery",
• The regulator is equipped with an internai relief valve. which give a flow capacity of 2,3 or 4 times the flow of one
• A strainer protects the regulator at the in/et side. regulator, with the same high regulating performances.
e PRINCIPLE OF OPERATION
REGULATING
p
The pressure reduction is done in
two stages:
The first stage reduction is taken
over the inlet plug 10 and the seat
ring 11. Tightness is ensured
through the plug dise seat 10
which closes on the seat ring
11. Pressure regulation is
controlled by the 1 st
stage diaphragm 20,
which sen ses
intermediate pressure
on one side and on the
other side the set
pressure of the spring
21.
The second stage
reduction is taken over
the regulating plug 12
and the seat ring 13.
Pressure reduction is
controlled by the 2"d stage
diaphragm, which senses
outlet pressure on one side and
on the other the set pressure of 20 13
the spring 22. This spring is factory
pre-set. Finally on modules other than
the BCH, the trip set lever functions also
as trip lever, which closes the second stage regulating plug 12.
8 Regulators
e 1NSTALLATION The regulator can be mounted in any position.
lnstall using schema C14 (example).
B6
Pressure sensing is internai and the regulator does not
require external sensing lines.
Use the torque indicated on the inlet connection.
CONNECTIONS
Pe Pa lnlet Sphero-conical or fiat joint connection
Outlet Flat meter joint connection
Vent 10 mm or customised size
•
C14
Pe Pa
e DIMENSIONS & WEIGHT DIMENSIONS 810, 825, 840, 8CH30
60 85
r21-
DIMENSIONS 86
___
10_3____
1
I
0
<D
0
<D
WEIGHT
86 1 kg
B 10 2 kg
B 25 2 kg Characteristics, dimensions and diagrams
B 40 2 kg can bind FRANCEL only after confirmation.
BCH 30 2 kg
REQUIRED OROER INFORMATION
STANDARD REGULATORS
SPECIAL REGULATORS
Select the type
Specify
Standard characteristics:
• lnlet pressure maxi mini:
see table C02
� 86 B10 B 25 B 40 BCH 30 • Outlet pressure:
see table C03
•c ._.
Pe min (bar) 0.5 0.5 0.5 0.7 0.8 • Maximum flow:
Pe max (bar) 4 4 4 4 4 see table C02
Pa (mbar) 21 21 21 21 300 • lnlet connections:
specify
Flow (m'/h(n)) 7.2 12 30 48 36 • Outlet connections:
lnlet * 3/4" use the available information on commercial meters
Outlet ** 1"1/4 • Vent connection
C16a
• Relief valve setting
• Sphero-conical connection, •• Flat joint connetction
• Option underground module
• Option manual pressure setting
Standard protection • Option special pain!
86 : unpainted
Others : vinyl finish
Batteries and Underground modules : polyurethane paint
<D
I
0
z