DSZH R32 refrigerant bottle delivers 1 kg of hydrofluoroolefin refrigerant for HVAC system charging and maintenance. With a boiling point of -51.7 °C and molecular weight of 52 g/mole, it supports modern air…

SKU 3G-CBM-01460

Also listed as: COR 30014 · COR-30014

Brand
DSZH
Item
R32 refrigerant bottle 1kg
Category
HVAC Tools
UNSPSC
41112509 — Air velocity and temperature monitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

DSZH
product
R32 refrigerant
boiling point
-51.7 °C
melting point
-136 °C
chemical formula
CH2F2
molecular weight
52 g/mole
water solubility
280 g/l (15°C, 1.013 bar)
flammability limits
13.1% - 28.4%
relative density liquid
1.1

Datasheet Content

Safety Data Sheet According to Regulation (EU) No. 2015/830 1907/2006 (REACH), Annex II Version: 1.0/EN Revision date: 12/2015 26/12/2010 Trade name: R32 Printing date: 26/12/2010 Section 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifier Trade name: HFC R32 Substance name: Difluoromethane REACH Reg. No.: The substance has been pre-registered. The transition time according to REACH Regulation, Article 23 is still not expired. Pre-reg. No.: 17-2119445508-34-0000 CAS No.: 75-10-5 EC No.: 200-839-4 1.2 Relevant identified uses of the substance or mixture and uses advised against Identified uses: Used as refrigerant, an important component of R22's replacement. Uses advised against: No uses advised against. 1.3 Details of the supplier of the SDS Only Representative: REACH COMPLIANCE SERVICES LIMITED Address: 306 The Capel Building, Mary's Abbey, Dublin 7, Ireland E-mail: [email protected] Manufacturer: JINHUA YONGHE FLUOROCHEMICAL CO., LTD. Address: Mariel JINXI srl DEVELOPMENT AREA, JINHUA, ZHEJIANG, CHINA Via Olubi, 5 - 28013 GATTICO (NO) ITALY E-mail: [email protected] [email protected] Telephone: +86+39 Tel. 5790322 83186711 838319 Fax: +86 579 83186717 Importer: Address: E-mail: Telephone: Fax: 1.4 Emergency telephone number +86 +39579 660119(China) 0322 838319 Section 2: Hazards identification 2.1 Classification of the substance or mixture Classification according to Regulation (EC) No 1272/2008[CLP] Flammable gases, category 1; H220 Gases under pressure (Liquefied gases); H280 -- Page 1 / 11 -- Safety Data Sheet According to Regulation (EU) No. 2015/830 1907/2006 (REACH), Annex II Version: 1.0/EN Revision date: 12/2015 26/12/2010 Trade name: R32 Printing date: 26/12/2010 Classification according to Council Directive 67/548/EEC [DSD] F+; R12 Additional information Full text of R-phrase(s) and H-statement(s): see section 16. 2.2 Label elements Labelling according to Regulation (EC) No 1272/2008 [CLP] Substance name: Difluoromethane Hazard pictogram(s): GHS02 GHS04 Signal word: Danger Hazard statements: H220 Extremely flammable gas. H280 Contains gas under pressure; may explode if heated. Precautionary statements: Prevention: P210 Keep away from heat/sparks/open flames/hot surfaces.-No smoking. Response: P377 Leaking gas fire: Do not extinguish, unless leak can be stopped safely. P381 Eliminate all ignition sources if safe to do so. Storage: P410 + P403 Protect from sunlight. Store in a well-ventilated place. Supplemental Hazard information (EUH): No information available. 2.3 Other hazards Low acute toxicity. Very high atmospheric concentrations may cause anaesthetic effects and asphyxiation. Liquid splashes or spray may cause freeze burns to skin and eyes. Fluorinated greenhouse gases, which has climatic warming potential. Section 3: Composition/information on ingredients 3.1 Substance information Molecular Classification according Substance name Synonyms CAS No. EC No. % (w/w) formula to DSD Difluoromethane HFC 32 75-10-5 200-839-4 CH2F2 F+; R12 ≥99.8 Molecular Classification according Substance name Synonyms CAS No. EC No. % (w/w) formula to CLP Flam. Gas 1; H220 Difluoromethane HFC 32 75-10-5 200-839-4 CH2F2 ≥99.8 Press. Gas (Liq. gas); H280 Remark: The rest unspecified ingredients are impurities, and they are not hazard. Full text of R-phrase(s) and H-statement(s): see section 16. -- Page 2 / 11 -- Safety Data Sheet According to Regulation (EU) No. 2015/830 1907/2006 (REACH), Annex II Version: 1.0/EN Revision date: 12/2015 26/12/2010 Trade name: R32 Printing date: 26/12/2010 Section 4: First aid measures 4.1 Description of first aid measures General notes: In all cases of doubt, or when symptoms persist, seek medical attention. Following inhalation: Remove patient from exposure, keep warm and at rest. Administer oxygen if necessary. Apply artificial respiration if breathing has ceased or shows signs of failing. In the event of cardiac arrest apply external cardiac massage. Obtain immediate medical attention. Following skin contact: Thaw affected areas with water. Remove contaminated clothing. Caution: clothing may adhere to the skin in the case of freeze burns. After contact with skin, wash immediately with plenty of warm water. If irritation or blistering occur, obtain medical attention. Following eye contact: Immediately irrigate with eyewash solution or clean water, holding the eyelids apart, for at least 10 minutes. Obtain immediate medical attention. Following ingestion: Unlikely route of exposure. Do not induce vomiting. Provided the patient is conscious, wash out mouth with water and give 200-300 ml (half a pint) of water to drink. Obtain immediate medical attention. Notes for the doctor: Treat symptomatically and supportively. Treatment may vary with condition of victim and specifics of incident. 4.2 Most important symptoms and effects, both acute and delayed Inhalation Very high atmospheric concentrations may cause anaesthetic effects and asphyxiation. An inhalation study in dogs has shown that HFC 32, unlike analogous substances, does not cause cardiac sensitization at concentrations up to 35% v/v. Skin Contact Liquid splashes or spray may cause freeze burns. Unlikely to be hazardous by skin absorption. Eye Contact Liquid splashes or spray may cause freeze burns. Ingestion Highly unlikely - but should this occur freeze burns will result. 4.3 Indication of the immediate medical attention and special treatment needed Persons with pre-existing skin, eye, or respiratory disease may be at increased risk from the irritant or allergic properties of this material. Attending physician should treat exposed patients symptomatically. Section 5: Fire-fighting measures 5.1 Extinguishing media Suitable extinguishing media: -- Page 3 / 11 -- Safety Data Sheet According to Regulation (EU) No. 2015/830 1907/2006 (REACH), Annex II Version: 1.0/EN Revision date: 12/2015 26/12/2010 Trade name: R32 Printing date: 26/12/2010 In case of fire in the surroundings: use appropriate extinguishing media. Unsuitable extinguishing media: For this substance/mixture no limitations of extinguishing agents are given. 5.2 Special hazards arising from the substance or mixture Substance is combustible. Containers may burst if overheated. Decomposition products may include the following materials: carbon dioxide, carbon monoxide, halogenated compounds(hydrogen fluoride). 5.3 Advice for fire-fighters Shut off gas supply if this can be done safely. If possible, take container out of dangerous zone. Cool cylinders with water spray. Self-contained breathing apparatus (SCBA) may be required if cylinders rupture or release under fire conditions. Section 6: Accidental release measures 6.1 Personal precautions, protective equipment and emergency procedures Immediately contact emergency personnel. Keep unnecessary personnel away. Use suitable protective equipment (section 8). Shut off gas supply if this can be done safely. Isolate area until gas has dispersed. 6.2 Environmental precautions Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided. 6.3 Methods and material for containment and cleaning up Allow small spillages to evaporate provided there is adequate ventilation. Large spillages: Ventilate area. Contain spillages with sand, earth or any suitable adsorbent material. Prevent liquid from entering drains, sewers, basements and work pits since the vapour may create an explosive or suffocating atmosphere. 6.4 Reference to other sections See Section 7 for information on safe handling. See section 8 for information on personal protection equipment. See Section 13 for information on disposal. Section 7: Handling and storage 7.1 Precautions for safe handling Keep away from sources of ignition - No Smoking. Take precautionary measures against static discharges. -- Page 4 / 11 -- Safety Data Sheet According to Regulation (EU) No. 2015/830 1907/2006 (REACH), Annex II Version: 1.0/EN Revision date: 12/2015 26/12/2010 Trade name: R32 Printing date: 26/12/2010 Avoid inhalation of high concentrations of vapours. Atmospheric levels should be controlled in compliance with the occupational exposure limit. Atmospheric concentrations well below the occupational exposure limit can be achieved by good occupational hygiene practice. The vapour is heavier than air, high concentrations may be produced at low levels where general ventilation is poor, in such cases provide adequate ventilation or wear suitable respiratory protective equipment with positive air supply. Avoid contact between the liquid and skin and eyes. 7.2 Conditions for safe storage, including any incompatibilities Keep in a well ventilated place. Keep in a cool place away from fire risk,…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DSZH Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

DSZH R32 refrigerant bottle delivers 1 kg of hydrofluoroolefin refrigerant for HVAC system charging and maintenance. With a boiling point of -51.7 °C and molecular weight of 52 g/mole, it supports modern air conditioning applications requiring low-GWP alternatives.

Frequently Asked Questions

Where can I order the DSZH R32 1kg refrigerant bottle worldwide?

Order directly from 3G Electric, an authorised HVAC refrigerant distributor. We handle worldwide delivery, logistics, and customs clearance. Lead time on request — contact our procurement team for availability and pricing.

What are the key specifications of DSZH R32 refrigerant?

DSZH R32 contains 1 kg of hydrofluoroolefin refrigerant with a boiling point of -51.7°C, molecular weight of 52 g/mole, and relative liquid density of 1.1. Flammability range is 13.1%–28.4%. Ideal for modern low-GWP air conditioning systems.

Is R32 suitable for my HVAC system?

R32 is a low-GWP hydrofluoroolefin designed for modern air conditioning applications requiring environmental compliance. Verify compatibility with your system's specifications and charging procedure before use. Consult equipment documentation or contact our technical support team.

Used in

Common applications for DSZH
Split-system air-conditioner service: DSZH manifold bases and SAE/NPT reducers integrate with technician gauge sets for pressure monitoring and refrigerant charge.
Rooftop packaged unit maintenance: Flare connector caps, hose tips, and union fittings expedite field replacement of damaged lines and adapters on commercial cooling systems.
Refrigerant recovery and recycling: DSZH bottle adapters (R600A-rated) connect recovery cylinders to hose lines, enabling safe extraction of flammable and standard refrigerants.
Process-cooling loop installation: SAE straight male/female unions and reducers support temporary or permanent manifold assembly on industrial water-chilled equipment.
Heat-pump seasonal service: DSZH dudgeon extensions and adapter kits allow technicians to connect diagnostic gauges to restricted or recessed access ports on reversing-valve manifolds.
Field emergency repairs: Individual DSZH fittings stocked in stock allow technicians to repair or modify hose connections on-site without returning to the shop for components.

DSZH Products

3G Electric supplies DSZH hvac tools. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
DSZH
DSZH
Refrigerant bottle R1234YF 900gr (including deposit)
DSZH
DSZH
Refrigerant bottle R410A 800 GR (including deposit)
DSZH
DSZH
Refrigerant bottle R134A 900 GR (incl. deposit)
DSZH
DSZH
Isobutane refrigerant bottle R600 420 GR (including deposit)
DSZH
DSZH
Refrigerant bottle 422b 850 GR (including deposit)
DSZH
DSZH
Refrigerant bottle R407C 900 GR (including deposit)

More from DSZH

View all DSZH parts
Transfer bottle 12kg gray CBM DO NOT RECOVER FULL BOTTLES
DSZH
Transfer bottle 12kg gray CBM DO NOT RECOVER FULL BOTTLES
DSZH
DSZH
Refrigerant bottle R404 800 GR (including deposit)
DSZH
DSZH
Dehydrating liquid 28.3G Thawzone
DSZH
DSZH
Heat strip for spring bottle
DSZH
DSZH
Dye cleaner 29028004
DSZH
DSZH
Tube cutter D.4X16 imperial 21004005
DSZH
DSZH
Torque wrench kit 1/4 3/8 1/2 TA771FC
DSZH
DSZH
Refrigerant bottle R290 370gr (including deposit)