DSZH Isobutane refrigerant bottle R600 420 GR (including deposit)

DSZH R600a isobutane refrigerant bottle supplies 420 g of refrigerant for HVAC maintenance and charging applications. Features a flash point of -82°C at 1 bar and boiling point of -11.7°C at 1 bar, making it suitable…

SKU 3G-CBM-01459

Also listed as: COR 30012 · COR-30012

Brand
DSZH
Item
Isobutane refrigerant bottle R600 420 GR
Category
HVAC Tools
UNSPSC
41112509 — Air velocity and temperature monitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

DSZH
volume
< 1000 mL
product
R600a isobutane refrigerant
flash point
-82°C at 1 bar
boiling point
-11.7°C at 1 bar
contents mass
420 g
melting point
-159.6°C at 1 bar
molecular weight
58.1
auto ignition temperature
477°C

Datasheet Content

Material Safety Data Sheet according to directive (UE) 453/2010 Page 1 of 6 R600a < 1000 mL Code: TR600 1.IDENTIFICATION OF PREPARATION AND SOCIETY 1.1 Description trade: R600a < 1000 mL Code: TR600 1.2 Uses planned: Industry: Refrigerant and conditioning Type of use: Refrigerant Application: Professional 1.3 Society: MARIEL S.R.L. Via Olubi, 5 - 28013 - GATTICO (NO) - Italy Phone: +39 0322 838319 Fax: +39 0322 838813 e-mail: [email protected] 1.4 Emergency number: + 39 0322 838319 - 8.30-12.30 / 13.30-17.30 Medical Center (Italy) ( 24/24 h service) Pavia +39 0382 24444 (CAV IRCCS Fondazione Maugeri – Pavia - Italy) Milano +39 02 66101029 (CAV Ospedale Niguarda Ca’ Granda – Milano - Italy) Bergamo +39 800 883300 (CAV Ospedali Riuniti – Bergamo - Italy) Firenze +39 055 7947819 (CAV Ospedale Careggi – Firenze - Italy) Roma +39 06 3054343 (CAV Policlinico Gemelli – Roma - Italy) Roma +39 06 49978000 (CAV Policlinico Umberto I – Roma - Italy) Napoli +39 081 7472870 (CAV Ospedale Cardarelli – Napoli - Italy) 2. IDENTIFICATION OF DANGERS Reg. CE 1272/2008: H220 – Extremely flammable. H280 – Pressurised container; the container may burst with high temperature. P210 – Keep away from sources of ignition - No smoking. P377 - Take precautionary measures against static discharges. P381 – Eliminare ogni fonte di accensione se non c'è pericolo. P403 – Keep container in a well-ventilated place; 2.1 Hazards information: Liquefied gas. Extremely flammable. 2.2 Classification CE : F+;R12 Material Safety Data Sheet according to directive (UE) 453/2010 Page 2 of 6 R600a < 1000 mL Code: TR600 3. COMPOSITION AND INFORMATION ON INGREDIENTS 3.1 Description: Name of the chemical substance: Isobutane. 100% Isobutane EC 200-857-2 CAS 75-28-5 For more information on hazardous components, see sections 8, 11, 12 and 16. 4. FIRST AID MEASURES If inhaled, remove to fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. Get medical attention. Notes to physician: Do not give adrenaline or similar drugs. 4.1 Inhalation: In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation. In low concentrations may cause narcotic effects. Symptoms may include dizziness, headache, nausea and loss of co-ordination. Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Apply artificial respiration if breathing stopped. 4.2 Skin Contact: Dermal contact with rapidly evaporating liquid could result in freezing of the tissues or frostbite. In case of contact with liquid, warm frozen tissues with water and get medical attention. Remove contaminated clothing and shoes. Wash clothing before reuse. 4.3 Eye Contact: Immediately flush eyes with a large amount of water for at least 15 minutes. If symptoms exist and/or persist, get prompt medical attention. 4.4 Ingestion: As this product is a gas, refer to the inhalation section. Do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention. 5. FIRE FIGHTING MEASURES 5.1 Extinguishing Agents: Extremely flammable. All known extinguishants can be used. 5.2 Unusual Hazards: Exposure to fire may cause containers to rupture/explode. 5.3 Personal Protective Equipment: Fire-fighters should wear self-contained positive pressure breathing apparatus (SCBA) and full turnout gear. 5.4 Hazardous thermal decomposition products Special exposure hazards: Incomplete combustion may form carbon monoxide. Move away from the container and cool with water from a protected position. Do not extinguish a leaking gas flame unless absolutely necessary. Spontaneous. Material Safety Data Sheet according to directive (UE) 453/2010 Page 3 of 6 R600a < 1000 mL Code: TR600 6. ACCIDENTAL SPILL OR LEAK RELEASE INFORMATION 6.1 Personal Protection: Immediately contact emergency personnel. Keep unnecessary personnel away. Use suitable protective equipment (Section 8). Provide adequate ventilation. In case of insufficient ventilation, wear suitable respiratory equipment. 6.2 Procedures: Stop leak if without risk. Spillages may evaporate rapidly. 7. HANDLING AND STORAGE 7.1 FIRE AND EXPLOSIVE PROPERTIES: Keep container below 50°C in a well ventilated plac e. 7.2 Storage Conditions: Store in original container, protected from direct sunlight. Keep container tightly closed in a cool, well- ventilated place. - Handling Procedures: Segregate from oxidant gases and other oxidants in store. Ensure equipment is adequately earthed. Suck back of water into the container must be prevented. Purge air from system before introducing gas. Do not allow backfeed into the container. Use only properly specified equipment which is suitable for this product, its supply pressure and temperature. Contact your gas supplier if in doubt. Keep away from ignition sources (including static discharges). Refer to supplier's container handling instructions. 8. EXPOSURE CONTROLS AND PERSONAL PROTECTION 8.1 Exposure Limits (TLV) TLV-TWA TLV-STEL AGCIH 2001 ppm mg/m3 ppm mg/m3 Isobutane 800 1900 TLV - Threshold Limit Value, TWA - Time Weighted Average, STEL - Short Term Exposure Limit. 8.2 Ventilation: Provide adequate ventilation. Do not enter storage areas and confined spaces unless adequately ventilated. Respiratory Protection: In case of insufficient ventilation, wear suitable respiratory equipment. Recommended: supplied-air respirator. - Eye Protection: Recommended: safety glasses with side shields, splash goggles. Possible: face shield. - Hand Protection: Insulated gloves suitable for low temperatures. Recommended: butyl rubber Material Safety Data Sheet according to directive (UE) 453/2010 Page 4 of 6 R600a < 1000 mL Code: TR600 8.2.2 Other Protective Equipment: 9. TYPICAL PHYSICAL PROPERTIES: - State : liquefied gas - Color : incolor - Odor Characteristics : Inodor - Molecular weight : 58.1 - Solubility in Water : 0.03 g/100ml a 25°C a 1013 hPa - Melting point : -159.6 °C a 1 bar - Boiling Point : -11.7 °C a 1 bar - Flash point : -82 °C a 1 bar - Auto-ignition temperature : 477 °C - Relative density : 2.01 Air=1 - Critical temperature : 135 °C - Flammability limit : low 1.80-high 8.44 In air at 1 bar (% vol) 10. STABILITY AND REACTIVITY: 10.1 Chemical Stability: Stable under normal conditions. 10.2 Hazardous Decomposition products: These products carbon oxides (CO, CO2). 10.3 Incompatibility: May react violently with oxidants. Can form explosive mixture with air. 10.4 Conditions to Avoid: In a fire or if heated, a pressure increase will occur and the container may burst. Pressurised container: protect from sunlight and do not expose to temperature exceeding 50°C. Do not pierce or burn, even after use. 11. TOXICOLOGICAL INFORMATION Effects: No known toxicological effects from this product. Cancinogenic Effects: These effects are not identified. For more information on hazardous components, see sections 2 and 8. Material Safety Data Sheet according to directive (UE) 453/2010 Page 5 of 6 R600a < 1000 mL Code: TR600 12. ECOLOGICAL INFORMATION Persistence and Degradation: - ODP : 0 No known ecological damage caused by this product. 13. DISPOSAL INFORMATION Do not discharge into areas where there is a risk of forming an explosive mixture with air. Waste gas should be flared through a suitable burner with flash back arrestor. Do not discharge into any place where its accumulation could be dangerous. Contact supplier if guidance is required. Procedure: Disposal of aerosol containers must be in accordance with local and national regulations. 14. TRANSPORT INFORMATION 14.1 Transport on road, Regular 94/55/CE (ADR 2013): Class: 2 Shipping Isobutane Hazard Class 2.1 N. UN 1950 Aerosol description Code of classification: 5 Documents of transport: Documents of transport 14.2 Transport via sea (IMDG 32-04): Class: Shipping Isobutane Hazard 2.1 N. UN 1950 Aerosol description Class Documents of transport: Documents of boarding. 14.3 Air freight (ICAO/IATA): Classe: Shipping Isobutane Hazard Class 2.1 N. UN 1950 Aerosol description Documents of transport: Documents of aerial boarding. 15. REGULATORY INFORMATION Reg. CE 1272/2008: H220 – Extremely flammable. H280 – Pressurised container; the container may burst with high temperature. P210 – Keep away from sources of ignition - No smoking. P377 - Take precautionary measures against static discharges. P381 – Eliminare ogni fonte di accensione se non c'è pericolo. P403 – Keep container in a well-ventilated place; Material Safety Data Sheet according to directive (UE) 453/2010 Page 6 of 6 R600a < 1000 mL Code: TR600 16. OTHER INFORMATION Text of R phrases mentioned in section 2: Extremely flammable. Sure to read the safety information of Mariel. For more information contact the office or authorized distributors of Mariel. Legislations on MSDS: Safety Data Sheet agrees with the REACH directive. Version 3: Date of revision: 10/02/2014 All information, recommendations, and suggestions made by Mariel srl. (“Company”) appearing herein concerning our product are based upon tests and data believed to be reliable. However, because of the variable characteristics of analytical procedures and samples, and the inability to control its customers’ uses of…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DSZH Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

DSZH R600a isobutane refrigerant bottle supplies 420 g of refrigerant for HVAC maintenance and charging applications. Features a flash point of -82°C at 1 bar and boiling point of -11.7°C at 1 bar, making it suitable for low-temperature refrigeration systems requiring precise thermal control.

Frequently Asked Questions

Where can I buy DSZH R600 420g isobutane refrigerant worldwide?

Order the DSZH R600a refrigerant bottle from 3G Electric, an authorized supplier serving technicians globally. We manage logistics, customs clearance, and worldwide delivery. Lead time on request.

What is the flash point and boiling point of this R600a refrigerant?

The DSZH R600 420 g bottle has a flash point of -82°C at 1 bar and a boiling point of -11.7°C at 1 bar, making it suitable for low-temperature refrigeration system charging and maintenance.

What is the net refrigerant mass in the DSZH bottle?

This DSZH R600a bottle contains 420 g of isobutane refrigerant. The bottle volume is less than 1000 mL, and the melting point is -159.6°C at 1 bar, suitable for precision HVAC applications.

Used in

Common applications for DSZH
Split-system air-conditioner service: DSZH manifold bases and SAE/NPT reducers integrate with technician gauge sets for pressure monitoring and refrigerant charge.
Rooftop packaged unit maintenance: Flare connector caps, hose tips, and union fittings expedite field replacement of damaged lines and adapters on commercial cooling systems.
Refrigerant recovery and recycling: DSZH bottle adapters (R600A-rated) connect recovery cylinders to hose lines, enabling safe extraction of flammable and standard refrigerants.
Process-cooling loop installation: SAE straight male/female unions and reducers support temporary or permanent manifold assembly on industrial water-chilled equipment.
Heat-pump seasonal service: DSZH dudgeon extensions and adapter kits allow technicians to connect diagnostic gauges to restricted or recessed access ports on reversing-valve manifolds.
Field emergency repairs: Individual DSZH fittings stocked in stock allow technicians to repair or modify hose connections on-site without returning to the shop for components.

DSZH Products

3G Electric supplies DSZH hvac tools. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Related products

More from DSZH

View all DSZH parts
Transfer bottle 12kg gray CBM DO NOT RECOVER FULL BOTTLES
DSZH
Transfer bottle 12kg gray CBM DO NOT RECOVER FULL BOTTLES
DSZH
DSZH
Refrigerant bottle R404 800 GR (including deposit)
DSZH
DSZH
Dehydrating liquid 28.3G Thawzone
DSZH
DSZH
Heat strip for spring bottle
DSZH
DSZH
Dye cleaner 29028004
DSZH
DSZH
Tube cutter D.4X16 imperial 21004005
DSZH
DSZH
Torque wrench kit 1/4 3/8 1/2 TA771FC
DSZH
DSZH
Refrigerant bottle R290 370gr (including deposit)