We ship worldwide — Singapore, Australia, Malaysia, Indonesia, Philippines, India, Middle East & more

Image not available
CBMHVAC & Refrigeration

CBM Leak Lock teflon 39 ml

CBM Leak Lock Gold is a teflon-based sealant for air conditioning systems, supplied in 39 ml cartridges with a density of 1.2 g/cm³. Designed for sealing refrigerant leaks in HVAC equipment and mobile cooling…

SKU 3G-CBM-01052

Also listed as: CLI 05204 · CLI-05204

Brand
CBM
Item
Leak Lock teflon 39 ml
Category
HVAC & Refrigeration
UNSPSC
40101701 — Air conditioners
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

CBM
type
Sealant
volume ml
39
product name
Leak Lock Gold
density g cm3
1.2
vapor pressure hpa
59

Datasheet Content

Page 1/12 Safety Data Sheet according to 1907/2006/EC (REACH), 1272/2008/EC (CLP), and GHS Printing date 09.04.2013 Revision: 04.04.2013 1 Identification of the substance/mixture and of the company/undertaking · 1.1 Product identifier · Trade name: LEAK LOCK GOLD · Article number: 11001,11004,11016,11128,11550 · 1.2 Relevant identified uses of the substance or mixture and uses advised against No further relevant information available. · Application of the substance / the preparation Sealant · 1.3 Details of the supplier of the Safety Data Sheet · Manufacturer/Supplier: Highside Chemicals, Inc. 11114 Reichold Road Gulfport, MS 39503 USA Phone: (228) 896-9220 · 1.4 Emergency telephone number: ChemTel Inc. (800)255-3924, +1 (813)248-0585 2 Hazards identification · 2.1 Classification of the substance or mixture · Classification according to Regulation (EC) No 1272/2008 GHS02 flame Flam. Liq. 2 H225 Highly flammable liquid and vapour. GHS07 STOT SE 3 H336 May cause drowsiness or dizziness. · Classification according to Directive 67/548/EEC or Directive 1999/45/EC F; Highly flammable R11: Highly flammable. R67: Vapours may cause drowsiness and dizziness. · Information concerning particular hazards for human and environment: The product has to be labelled due to the calculation procedure of the "General Classification guideline for preparations of the EU" in the latest valid version. · Classification system: The classification is according to the latest editions of the EU-lists, and extended by company and literature data. The classification is in accordance with the latest editions of international substances lists, and is supplemented by information from technical literature and by information provided by the company. · 2.2 Label elements · Labelling according to Regulation (EC) No 1272/2008 The product is classified and labelled according to the CLP regulation. (Contd. on page 2) 36.0.22 Page 2/12 Safety Data Sheet according to 1907/2006/EC (REACH), 1272/2008/EC (CLP), and GHS Printing date 09.04.2013 Revision: 04.04.2013 Trade name: LEAK LOCK GOLD (Contd. of page 1) · Hazard pictograms GHS02 GHS07 · Signal word Danger · Hazard statements H225 Highly flammable liquid and vapour. H336 May cause drowsiness or dizziness. · Precautionary statements P101 If medical advice is needed, have product container or label at hand. P102 Keep out of reach of children. P103 Read label before use. P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking. P280 Wear protective gloves and eye protection. P233 Keep container tightly closed. P261 Avoid breathing mist/vapours/spray. P303+P361+P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. P370+P378 In case of fire: Use for extinction: CO2, powder or water spray. P403+P235 Store in a well-ventilated place. Keep cool. · Hazard description: · WHMIS-symbols: B2 - Flammable liquid D2B - Toxic material causing other toxic effects · NFPA ratings (scale 0 - 4) Health = 1 3 Fire = 3 1 0 Reactivity = 0 · HMIS-ratings (scale 0 - 4) HEALTH 1 Health = 1 FIRE 3 Fire = 3 REACTIVITY 0 Reactivity = 0 · HMIS Long Term Health Hazard Substances 64-17-5 ethanol · 2.3 Other hazards · Results of PBT and vPvB assessment · PBT: Not applicable. (Contd. on page 3) 36.0.22 Page 3/12 Safety Data Sheet according to 1907/2006/EC (REACH), 1272/2008/EC (CLP), and GHS Printing date 09.04.2013 Revision: 04.04.2013 Trade name: LEAK LOCK GOLD (Contd. of page 2) · vPvB: Not applicable. 3 Composition/information on ingredients · 3.2 Mixtures · Description: Mixture of substances listed below with nonhazardous additions. · Dangerous components: CAS: 64-17-5 ethanol 25-50% EINECS: 200-578-6 F R11 Index number: 603-002-00-5 Flam. Liq. 2, H225 CAS: 14807-96-6 Talc (Mg3H2(SiO3)4) 25-50% EINECS: 238-877-9 CAS: 67-63-0 propan-2-ol <10% EINECS: 200-661-7 Xi R36; F R11 Index number: 603-117-00-0 R67 Flam. Liq. 2, H225 Eye Irrit. 2, H319; STOT SE 3, H336 · Additional information: For the wording of the listed risk phrases refer to section 16. Dried product contains substances which are considered nuisance dusts which require a NIOSH Breathing airborne particles or dust from mixing, spraying, sanding, grinding, etc. may cause irritation to respiratory tract. 4 First aid measures · 4.1 Description of first aid measures · General information: Symptoms of poisoning may even occur after several hours; therefore medical observation for at least 48 hours after the accident. Take affected persons out into the fresh air. · After inhalation: Supply fresh air. Seek medical treatment in case of complaints. · After skin contact: Immediately rinse with water. Clean with water and soap. If skin irritation continues, consult a doctor. · After eye contact: Remove contact lenses if worn. Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor. · After swallowing: Rinse out mouth and then drink plenty of water. Do not induce vomiting; call for medical help immediately. · 4.2 Most important symptoms and effects, both acute and delayed Dizziness (Contd. on page 4) 36.0.22 Page 4/12 Safety Data Sheet according to 1907/2006/EC (REACH), 1272/2008/EC (CLP), and GHS Printing date 09.04.2013 Revision: 04.04.2013 Trade name: LEAK LOCK GOLD (Contd. of page 3) Headache Nausea Thirst Disorientation · Hazards Condition may deteriorate with alcohol consumption. · 4.3 Indication of any immediate medical attention and special treatment needed Monitor circulation. If necessary oxygen respiration treatment. Medical supervision for at least 48 hours. Contains ethanol and isopropanol. 5 Firefighting measures · 5.1 Extinguishing media · Suitable extinguishing agents: Use fire extinguishing methods suitable to surrounding conditions. · For safety reasons unsuitable extinguishing agents: None. · 5.2 Special hazards arising from the substance or mixture In case of fire, the following can be released: Carbon monoxide (CO) · 5.3 Advice for firefighters · Protective equipment: Wear self-contained respiratory protective device. Wear fully protective suit. · Additional information Eliminate all ignition sources if safe to do so. Cool endangered receptacles with water spray. 6 Accidental release measures · 6.1 Personal precautions, protective equipment and emergency procedures Use respiratory protective device against the effects of fumes/dust/aerosol. Wear protective equipment. Keep unprotected persons away. Ensure adequate ventilation Keep away from ignition sources. Protect from heat. · 6.2 Environmental precautions: Dilute with plenty of water. Suppress gases/fumes/haze with water haze or fog. · 6.3 Methods and material for containment and cleaning up: Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust). Dilute with plenty of water. Dispose contaminated material as waste according to item 13. · 6.4 Reference to other sections See Section 7 for information on safe handling. See Section 8 for information on personal protection equipment. (Contd. on page 5) 36.0.22 Page 5/12 Safety Data Sheet according to 1907/2006/EC (REACH), 1272/2008/EC (CLP), and…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CBM Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

CBM Leak Lock Gold is a teflon-based sealant for air conditioning systems, supplied in 39 ml cartridges with a density of 1.2 g/cm³. Designed for sealing refrigerant leaks in HVAC equipment and mobile cooling applications.

Frequently Asked Questions

Where can I buy CBM Leak Lock Gold teflon sealant worldwide?

3G Electric is an authorized distributor of CBM Leak Lock Gold. We handle worldwide delivery and manage all logistics and customs documentation for seamless ordering across regions.

What is the lead time for CBM CLI05204 teflon sealant?

Lead time on request. 3G Electric sources this 39 ml cartridge to order. Contact our team with your quantity and delivery location for a precise delivery schedule.

What is the density and vapor pressure of CBM Leak Lock Gold sealant?

CBM Leak Lock Gold has a density of 1.2 g/cm³ and a vapor pressure of 59 hPa. These properties ensure reliable sealing performance in refrigerant HVAC and mobile cooling applications.

Used in

Common applications for CBM
Industrial boilers — CBM circulation pumps (mod. CM 30W) and solenoid valves (ELV series) for heating-loop control and pump staging.
Burner systems — CBM oil nozzles (FLU atomizer types), electrodes (ELC 200 mm), and solenoid coils (ELV 230V AC) for combustion ignition and flame supervision.
Plant maintenance and retrofit — CBM cable glands (CLI M25), motor couplings (ACC type D), and small-radius fittings (RAC 90°) for equipment reconfiguration and sensor integration.
Boiler water treatment — CBM chlorine test kits (DET free+combined) for feedwater and circulating-water quality monitoring in closed-loop systems.
Pump and motor assembly — CBM couplings, fittings, and cable glands for assembly and rewinding of industrial motors, circulation pumps, and auxiliary equipment.

CBM Products

3G Electric supplies CBM hvac & refrigeration. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
CBM
CBM
Leak Lock regulator 39 ml
Siphon
CBM
Siphon
CBM
CBM
Blue hose
Service valve seal kit 1/4"
CBM
Service valve seal kit 1/4"
CBM
CBM
Tip 35mm
C21-013 reservoir
CBM
C21-013 reservoir

More from CBM

View all CBM parts
Shock absorber support 700
CBM
Shock absorber support 700
CBM
CBM
Black coupling 80mm
CBM
CBM
Tube cutter 1/8 - 3/4
CBM
CBM
Vacuum pump pressure gauge vertical
CBM
CBM
Cable gland M20 for proximity switch
CBM
CBM
Set of 4 extensions 130 mm
CBM
CBM
71L/min battery vacuum pump
CBM
CBM
Black vertical right angle 80mm