The Allanson 444-659 Ferromagnetic Service Replacement Transformer is an ignition transformer for industrial combustion oil burners. It features a 240V input at 60Hz, with a secondary voltage of 10,000 volts and a…

SKU 3G-OTH-03213

Also listed as: 444659 · 444 659

Brand
Allanson
Item
444-659 Ferromagnetic Service Replacement Transformer for Industrial Combustion
Part Number
444-659
Category
Ignition Transformers
UNSPSC
39121003 — Instrument transformers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support

Delivery
Worldwide DHL shipping from Singapore; 7–14 business days door-to-door for most destinations.
Payment
Invoicing in USD. Bank transfer (SWIFT) and corporate PO accepted.

Technical Specifications

Allanson
Current
23mA
Can Size
Large Can Series
Grounding
Mid Point Ground
Application
OIL
Burner Type
INDUSTRIAL COMBUSTION
Hv Terminal
Rajah Connector
Junction Box
INTERNAL
Input Voltage
240V
Input Frequency
60Hz
Secondary Voltage
10000 Volt
Burner Manufacturer
INDUSTRIAL COMBUSTION

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Allanson 444-659 Ferromagnetic Service Replacement Transformer is an ignition transformer for industrial combustion oil burners. It features a 240V input at 60Hz, with a secondary voltage of 10,000 volts and a current of 23mA. The transformer includes a Rajah connector for the high-voltage terminal, internal junction box, and mid-point grounding. It comes in a Large Can Series size.

Frequently Asked Questions

What is the Allanson 444-659 ferromagnetic transformer used for?

The Allanson 444-659 is a service replacement ignition transformer designed for constant-duty commercial and industrial oil burners. It provides a reliable 10,000-volt ignition source for industrial combustion applications, ensuring consistent spark for heavy-duty oil-fired equipment.

What are the specifications of the Allanson 444-659 transformer?

The Allanson 444-659 operates at 240 V input, 60 Hz, with a secondary voltage of 10,000 V RMS and 23 mA short-circuit current. It features a large can size, mid-point grounding, internal junction box, and Rajah connector HV terminal. Storage temperature range is -40 to +80 °C.

Where to buy the Allanson 444-659 transformer in Singapore?

3G Electric supplies the Allanson 444-659 ferromagnetic transformer to Singapore. We source and deliver this industrial combustion component, handling logistics and customs clearance for your facility. Contact us for availability and lead time on this service replacement transformer.

How to install the Allanson 444-659 transformer?

Install the Allanson 444-659 by mounting it securely in the burner control panel, connecting the 240 V input to the primary terminals and the Rajah connector to the ignition electrode. Ensure the loading air gap is set between 1/8 and 3/16 inches for proper spark. Follow Allanson's guidelines for safe installation.

Used in

Common applications for Allanson
Industrial gas combustion — Allanson 1196-H ferromagnetic ignition transformer for constant-duty spark generation in commercial and industrial gas burners.
Carlin oil burner retrofit — Allanson 2730-630 ignition transformer for Carlin 99, 100, 101, and Card Miser burners, operating at 110V/50Hz.
Gordon Piatt burner service — Allanson 542-GP ignition transformer with 1/4-20 stud terminal for reliable ignition in Gordon Piatt gas burners.
PVI Industries oil heating — Allanson 421-663 double-pole transformer for oil-fired PVI Industries boilers, providing mid-point grounded ignition.
Commercial kitchen ventilation — Allanson DCC2C32700-120-277V LED power supply for dimmable hood lamp lighting in commercial kitchen exhaust systems.
Process heating systems — Allanson 1092-IC ignition transformer for industrial combustion applications requiring 25/20mA output and Rajah connector.
Not sure this is the right part? Photo-identify it

Allanson Products

3G Electric supplies Allanson ignition transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson 1196-IC Ferromagnetic Ignition Transformer for Industrial Combustion
Allanson
Allanson
Allanson 1092-IC Ferromagnetic Ignition Transformer for Industrial Combustion
Allanson
Allanson
Allanson 2742-359 Ignition Transformer, Industrial Combustion
Allanson
Allanson
Allanson 1112-IC Ferromagnetic Ignition Transformer for Industrial Combustion

More from Allanson

View all Allanson parts
Allanson 1092-H Ferromagnetic Ignition Transformer for Industrial Combustion
Allanson
Allanson 1092-H Ferromagnetic Ignition Transformer for Industrial Combustion
Allanson
Allanson
Allanson 2742-662 Ignition Transformer for Gordon Piatt
Allanson
Allanson
Allanson 2742-500 Ignition Transformer
Allanson
Allanson
Allanson 2742-655-G Ignition Transformer for Power Flame
Allanson 542-GP Ferromagnetic Ignition Transformer for Gordon Piatt
Allanson
Allanson 542-GP Ferromagnetic Ignition Transformer for Gordon Piatt
Allanson
Allanson
Allanson 2729-411 Ferromagnetic Transformer for Abc
Allanson 542-H Ferromagnetic Ignition Transformer for Industrial Combustion
Allanson
Allanson 542-H Ferromagnetic Ignition Transformer for Industrial Combustion
Allanson 2714-633 Ferromagnetic Ignition Transformer for Carlin
Allanson
Allanson 2714-633 Ferromagnetic Ignition Transformer for Carlin

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first